La Crosse Technology WS-9020U 915MHZ instruction manual Care and Maintenance, Specifications

Page 32

CARE AND MAINTENANCE

Extreme temperatures, vibration and shock should be avoided as these may cause damage to the units and give inaccurate forecasts and readings.

When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or scouring agents as they may mark the LCD and casings.

Do not submerge the units in water.

Immediately remove all low powered batteries to avoid leakage and damage. Replace only with new batteries of the recommended type.

Do make any repair attempts to the units. Return it to their original point of purchase for repair by a qualified engineer. Opening and tampering with the units may invalidate their guarantee.

Do not expose the units to extreme and sudden temperature changes, this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy.

SPECIFICATIONS

Temperature measuring range:

Indoor

: +40°F to +139.8°F with Accuracy +/- 0.2°F resolution

 

-40ºC to +59.9ºC with Accuracy +/- 0.1ºC resolution

 

(“OF.L” displayed if outside this range)

Outdoor

: -39.8°F to +139.8°F with Accuracy +/- 0.2°F resolution

 

-39.9ºC to +59.9ºC with Accuracy +/- 0.1ºC resolution

 

(“OF.L” displayed if outside this range)

Relative humidity measuring range:

Indoor

:

1% to 99% with 1% resolution

 

 

(“- -” displayed when value < 1%; "99%"

 

 

displayed if value 99%)

Outdoor

:

1% to 99% with 1% resolution

 

 

(“1%” displayed when value 1%; "99%" is

 

 

played if value 99%)

Indoor temperature checking interval :

every 20 seconds

Indoor humidity checking interval

:

every 20 seconds

Outdoor temperature reception

:

every 4 seconds

32

Image 32
Contents Features Intelligent Weather StationRemote TEMPERATURE/HUMIDITY Sensor Quick SET-UP Guide Important Notes on Set-up and OperationBattery Installation Battery Change Function Keys Intelligent weather stationMIN/- key SET keyMAX/+ key Alarm key LCD ScreenManual Settings Time Zone Setting LCD Contrast Setting12/24 Hour Time Display Setting Daylight Time Saving ON/OFF Setting Manual Time SettingCalendar Setting Wwvb Time Reception ON/OFF SettingTemperature Unit Setting Relative AIR Pressure Unit SettingRelative Pressure Value Setting Language Display SettingTo Exit the Manual Setting Mode Outdoor Temperature and HumidityAdding Sensors Optional Indoor Relative Humidity and Indoor TemperatureToggling Between MIN/MAX Indoor and Outdoor Recordings To SET-UP of Multiple Sensors To View the MIN/MAX Data from Different Transmitters When more than 1 transmitter usedTo View MIN/MAX Indoor and Outdoor Records To Reset the MIN/MAX Values to Current Values Outdoor Channel RE-LEARN ModeWeather Alarm Setting To re-learn ALL channelsDefault alarm values LOW Outdoor Temperature Alarm SettingHigh Outdoor Temperature Alarm Setting Weather Alarm Operations Weather Alarms Weather data Hysteresis Alarm setting Minimum MaximumHysteresis Examples of changing weather icons Sunny Cloudy with Rainy IntervalsAIR Pressure Tendency Indicator AIR PressureBAR Graph Display AIR Pressure HistoryLOW Battery Indicator Weather InformationdisplayDetailed Information Shown in the Weather Display Remote TEMPERATURE/HUMIDITY Sensor / 915MHZ Reception Check Page Positioning the Intelligent Weather Station To wall mountPositioning the Remote Temperature / Humidity Sensor To wall mountCare and Maintenance SpecificationsWarranty Information Page FCC Disclaimer Statement according to FCC part