Karcher K 2.93 Ground Fault Circuit Interrupter Gfci Protection, Water Supply Cold Water Only

Page 5

stalled by a qualified electrician. Do not use any type of adapter with this pro- duct.

Ground Fault Circuit Interrupter

(GFCI) Protection

This product is supplied with a Ground Fault Circuit Interrupter (GFCI) built into the power cord plug. This device provi- des additional protection from the risk of electric shock. If power is interrupted in the line, the GFCI will automatically re- close the circuit to the load after power is restored. Depending on the GFCI mo- del, it may be necessary to manually operate the reset button to restore po- wer to the GFCI load circuit. If replace- ment of the plug or cord is needed use identical replacement parts.

SAVE THESE INSTRUCTIONS!

WATER SUPPLY (Cold Water Only)

￿CAUTION

Dirt in the feed water will damage the unit. To avoid this risk, we recommend fitting a water filter.

!Water hose must be at least 5/8 inch in diameter.

!Flow rate of water supply must not fall below 2 GPM (gallons per minu- te).

!Flow rate can be determined by run- ning the water for one minute into an empty 5-gallon container.

!The water supply temperature must not exceed 104°F/40°C.

!Never use the pressure washer to draw in water contaminated with sol- vents, e.g. paint thinners, gasoline, oil, etc.

!Always prevent debris from being drawn into the unit by using a clean water source.

English 5

Image 5
Contents English Español Français Safety Alert Symbols SpecificationsHigh Pressure Washer Operator Manual Kärcher Customer Support USAItem Description Model OverviewGrounding Instructions Important Safety InstructionsWater Supply Cold Water Only Ground Fault Circuit Interrupter Gfci ProtectionOperating Instructions Vario power nozzle Using the AccessoriesGfci Instructions DirtblasterDetergents can only be applied at low pressure Min Working with DetergentsOne Gallon ready to use Never useShutting Down & CLEAN-UP Winterizing and LONG-TERM Storage Care and Maintenance InstructionsCleaning the water inlet filter Maintenance Cleaning Tips English Optional Cleaning Accessories Detergent Foamer Attachment Racer Wide Area Surface CleanerWet Sandblasting Kit bayonet Symptom Cause Solution TroubleshootingWater emerges through Especificaciones Manual DE Usuario DEL Limpiador DE Alta PresiónDescripción de la pieza Vista General DEL Modelo¡ADVERTENCIA Toma DE Agua sólo agua fría ¡GUARDE Estas InstruccionesInstrucciones DE Funcionamiento Boquilla variable accionada Mecánicamente Utilización DE LOS AccesoriosLos detergentes sólo se pueden apli- car a baja presión mín Trabajar CON DetergentesUn galón listo para el uso Nunca utiliceApagado Y Limpieza Mantenimiento Limpieza del filtro de entrada de AguaLimpieza de cubiertas Consejos DE LimpiezaRecomendaciones Accesorios DE Limpieza Opcionales Accesorio espumador de Detergente Kit de limpieza de tubos de 25 pies BayonetaLimpiador de superficies de zonas Amplias T-Racer Servicio de asistencia al cliente de Kärcher de EE.UUAtención Localización Y Reparación DE AveríasOs están apretados Page Service à la clientèle aux Etats-Unis Symboles dalerte de sécuritéNettoyeur Haute Pression Manuel Dutilisation CaractéristiquesDescription des éléments GeneralitesInstructions de mise à terre Consignes DE Securite ImportantesAlimentation EN EAU eau froide seulement Protection par disjoncteur DifférentielMode Demploi Lance Vario Utilisation DES AccessoiresNe jamais utiliser Emploi DE DetergentsLitres 1 gallon prêt à lemploi Arret DE Lappareil ET Nettoyage Remisage Hivernal ET Entreposage a Long Terme Prendre UNE Pause ...cinq minutes ou plusConseils DE Nettoyage Français Accessoires DE Nettoyage EN Option Kit de sablage humide baïonnette Kit de nettoyage de conduite 25 Ft BaïonnetteEmbout moussant Nettoyeur grande surface T-RacerDe procéder à une quelconque réparati DépannageTergent obstrué