Nilfisk-ALTO 106269015 manual Maintenance

Page 15

NEPTUNE PE

7 Maintenance

7.1Maintenance Schedule

 

 

 

NEPTUNE

Every six

 

 

 

 

5-51 DE / 5-85 PE

 

 

 

 

months or

As

 

 

Weekly

only

 

 

500 operating

required

 

 

 

After the first 50

 

 

 

hours

 

 

 

 

operating hours

 

 

 

 

 

 

 

 

 

 

 

 

7.2.1

Water fi lters

 

 

 

 

 

 

 

 

 

7.2.2

Oil fi lter

 

 

 

 

 

 

 

 

 

7.2.3

Checking the pump oil quality

 

 

 

 

 

 

 

 

7.2.4 Changing the pump oil

 

 

 

 

 

 

 

7.2.5 Emptying the fuel oil tank

 

 

 

 

 

 

 

 

 

7.2.6

Flame Sensor

 

 

 

 

 

 

 

 

 

Service on engine: See attached user instructions for engine.

7.2Maintenance work 7.2.1 Water filters

7.2.2 Checking the pump oil quality

1.Unscrew quick coupling.

2.Remove fi lter with tool and clean it.

1.Check color of pump oil.

If the oil has a grey or white shade, change the oil (see chapter 7.2.3)

2.Top off oil level with fresh oil if necessary.

Oil type see chapter 9.4 Technical Specifi cations.

13

Image 15
Contents Neptune PE/DE Neptune 5-46 PE Contents General Important safety instructionsSymbols used to mark For your own safetyUnloader valve Store the cleaner where it will not be exposed to FrostTesting OperationDescription PurposeOperating elements Fill up fuel tank Before starting the machine19 mm Connections Connecting the spray lance to the spray gun Description of light indicatorsControl / Operation Neptune PE Techniques Applications and methods Vehicle Task Accessories Method Buildings and Equipment Task Accessories Method Protection After using the cleanerSwitching off Cleaner Storing / frostMaintenance Neptune Flame sensor Indications on Display TroubleshootingNeptune 5-51DE Adjust RPM on Other faultsWarranty Further informationCE Declaration of Conformity 46 PE 54 PE 61 PE 85 PE 51 DE 66 DE 72 DE Technical SpecificationsNeptune 5-51 DE Head Quarter