Model LG & LD Pool and Spa Heater

Page 9

 

 

 

 

Figure 8. Field Wiring Connections (LD).

Figure 9. Time Clock Wiring.

To install a time clock auxiliary switch into the heater wires (see Figure 9):

1.Remove heater door.

2.Remove the factory installed wire between terminals 1 and 2 on the terminal strip (see Figure 9).

3.Connect the wires from the time clock auxiliary switch to the two terminals. Use American Wire Gage (AWG) No. 14 gauge stranded copper wire with a temperature rating of 221°F (105°C) or greater.

The length of the wire between the heater and the time clock should not exceed 10-15 feet (4.57 m). The contact points of the time clock switch should be silver, or a low resistance alloy.

2F-3. Remote Operation

(Model LD Only)

The Laars Lite 2 pool/spa heater controls can be wired for remote operation. The CS-02 remote control permits switching from one temperature controller to the other and turning the heater on and off from a remote location. The CS-04 includes the same features as the CS-02 plus a remote tempera- ture controller. Contact Waterpik Laars for further information. Reference part numbers CS-02 and CS-04.

An interrupt (on/off) type remote can be connected by removing the jumper wire on the terminal block located in the control compartment (see Figure 6) and connecting the two wires from the remote to the two terminals on the terminal block. This type of remote control will turn the heater on or off, but will not switch between the two temperature controllers on the temperature control panel or allow for temperature adjustments.

To connect a 3-wire remote (not supplied by Waterpik Laars) to a Laars Lite 2 LD heater, order a wire harness assembly (part No. E0120000) which connects to the temperature control panel. Installation instructions are included with the wire harness assem- bly.

Consult with Waterpik Laars Service Department with questions about installing remotes other than Waterpik Laars.

2G. Water Flow System

2G-1. Flange Installation

The heater has 2" NPT universal header cou- plings. You can connect threaded 2" NPT iron pipe, unthreaded 1-1/2" iron pipe, 1-1/2" or 2" copper pipe without an adapter (see Figure 10).

Plastic piping (PVC Schedule 40) can be con- nected to the heater if local codes allow it, by using the CPVC nipples included with your heater.

To install plastic piping (see Figure 11):

1.Remove CPVC nipples from plastic bag.

2.Screw CPVC nipples into metal flange until tight, using teflon tape on plastic threads.

3.Attach PVC plumbing to CPVC pipes using PVC to CPVC cement only.

Image 11
Contents Outdoor Use Only Installation Laars Lite Pool and Spa HeaterTable of Contents 1A. Introduction Section1D. Technical Assistance 1C. Warranty2B. Field Assembly 1B. Description2C. Site Location 2C-1. Installation InformationUnited States 2C-2. Outdoor Installation2C-3. Flooring Typical Installation 2C-4. Indoor and Outdoor Shelter Installations2E-1. General Instructions 2D. Combustion and Ventilation Air Supply2E. Gas Supply and Piping 2F-1. General Information LD Only 2F. Electrical Wiring2E-2. Special Precautions for Propane Gas Model LD Wiring Diagram 92/7+$75,5,1*,$*5$0 2F-2. Auxiliary Time Clock Wiring2F-3. Remote Operation Model LD Only 2G-1. Flange Installation2G. Water Flow System 2G-2. Reversible Water Connections Piping installationFlue collector hold-down brackets 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals 2G-3. Check Valve Installation2G-5. Pressure Relief Valve 2G-6. Adjusting the Pressure Switch2G-4a. Water Chemistry 2G-7. Automatic Flow Control Valve 2G-8. Temperature Rise2G-9. Adjusting the Manual Bypass Valve Supply gas volume is too low3B-1. Model LD see 3B-2. Model LG see 3B. Lighting and Shutdown Procedures3C. Setting the Temperature Control 3A. General InformationDo not try to light any appliance Turn gas control knob clockwise Appliance switch to OFFReplace control access panel Service is to be performed 3B-1. Model LD Direct IgnitionWhat to do if YOU Smell GAS 3B-2. Model LG Standing Pilot3D-3. Spring Start-up 3D. Seasonal Care3D-1. Spring and Fall Operation 3D-2. Winterizing3G. Swimming Pool Energy Saving Tips 3F. Spa/Hot Tub Safety Rules3E. Water Chemistry 3H-1. Owner Inspection 4B. Parts List3H. Periodic Inspection 4A. General InformationOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Limited Warranty