Waterpik Technologies LG, LD operation manual 2G-3. Check Valve Installation

Page 14

Page 12

WATERPIK TECHNOLOGIES INC.

 

 

 

 

Heat Exchanger

End Baffles

Heat Exchanger

Combustion

Chamber Wall

Figure 16. Heat exchanger and end baffles.

13.Lift the heat exchanger assembly out of the heater. Reinstall heat exchanger 180 degrees (inlet/outlet header left) from it's original posi- tion.

14.After replacing the heat exchanger into the heater, the end baffles must be replaced. Each one is held in place by two screws which mount to the top of the combustion chamber wall. Reinstall the baffles on the front and rear of the heat exchanger before continuing with the "Reversible Water Connections" procedure.

15.Remove pressure switch retainer (plastic cable clamp) from the inner panel (allow pressure switch to float).

16.On U.S. models reroute pressure switch tube and thermostat bulb assembly through hole in left side of vestibule cover in reverse order. Canadian models have no cover on the left side of the vestibule. Relocate the pressure switch tube and temperature sensor through the open side of the vestibule.

17.Reinstall the temperature sensing bulb in the header, and fasten it with the retainer bracket and screw.

18.Reinstall the compression fitting at end of pres- sure switch tube into inlet/outlet header and tighten the fitting.

19.Route the white wiring from the high limit switches beside the heat exchanger and down to the original location following the pressure switch tubing. Secure white wires to the pressure switch tube with plastic wire ties.

20.Connect the white wire labeled PS to the pressure switch and the other white wire to its original location on the Fireman's switch.

21.Reinstall the drain plugs and tighten securely. Replace jacket/plug grommets.

22.Install the flue collector assembly. Be sure the front and rear panels of the flue collector are installed into the grooves on the front and rear combustion chamber heat shield panels. Be sure the sheet metal panels are not pinching any wires.

23.Attach the flue collector hold down clamps to the clips located under the two center header bolts.

24.Replace the gap closures and tighten the screws securely.

25.Double-check to make sure the wiring is not pinched against sharp edges, or resting on the flue collector assembly.

26.Reinstall rainshield assembly.

27.Replace the top assembly. Make sure the tabs are outside the heater jacket. Fasten the top assembly with the hex-head screws.

28.Install plastic tie wraps on wiring in the vestibule (controls compartment).

29.Install heater door.

30.Reinstall the vent cap or drafthood, if one was removed.

2G-3. Check Valve Installation

Install a check valve if there is any chance of back- siphoning when the pump stops. Do not install any other valve in the piping between the heater outlet and the pool, unless it is being used as a diverter valve.

2G-4. Chlorinators, Ozone Generators,

and Sanitizing Chemicals

The Waterpik Laars Lite 2 heater is manufac- tured with materials that are not compatible with high concentrations of ozone, chlorine, bromine, or other sanitizing chemicals. Heater damage caused by exces- sive chemicals or improper ozonization is not covered by the Waterpik Laars warranty. Be sure to adhere to the following:

When ozone is injected upstream of the heater, install an offgas mixing chamber, or an ozone bypass system between the heater and the ozone injector to prevent ozone and air from entering the heater.

Image 14
Contents Installation Laars Lite Pool and Spa Heater Outdoor Use OnlyTable of Contents Section 1A. Introduction1B. Description 1C. Warranty2B. Field Assembly 1D. Technical Assistance2C-1. Installation Information 2C. Site Location2C-4. Indoor and Outdoor Shelter Installations 2C-2. Outdoor Installation2C-3. Flooring Typical Installation United States2E-1. General Instructions 2D. Combustion and Ventilation Air Supply2E. Gas Supply and Piping 2F-1. General Information LD Only 2F. Electrical Wiring2E-2. Special Precautions for Propane Gas Model LD Wiring Diagram 2F-2. Auxiliary Time Clock Wiring 92/7+$75,5,1*,$*5$02F-3. Remote Operation Model LD Only 2G-1. Flange Installation2G. Water Flow System Piping installation 2G-2. Reversible Water ConnectionsFlue collector hold-down brackets 2G-3. Check Valve Installation 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals2G-5. Pressure Relief Valve 2G-6. Adjusting the Pressure Switch2G-4a. Water Chemistry 2G-8. Temperature Rise 2G-7. Automatic Flow Control ValveSupply gas volume is too low 2G-9. Adjusting the Manual Bypass Valve3A. General Information 3B. Lighting and Shutdown Procedures3C. Setting the Temperature Control 3B-1. Model LD see 3B-2. Model LG see3B-1. Model LD Direct Ignition Turn gas control knob clockwise Appliance switch to OFFReplace control access panel Service is to be performed Do not try to light any appliance3B-2. Model LG Standing Pilot What to do if YOU Smell GAS3D-2. Winterizing 3D. Seasonal Care3D-1. Spring and Fall Operation 3D-3. Spring Start-up3G. Swimming Pool Energy Saving Tips 3F. Spa/Hot Tub Safety Rules3E. Water Chemistry 4A. General Information 4B. Parts List3H. Periodic Inspection 3H-1. Owner InspectionOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Limited Warranty