Waterpik Technologies LD, LG operation manual Flue collector hold-down brackets

Page 13

Model LG & LD Pool and Spa Heater

Page 11

 

 

 

 

1.Remove heater door.

2.If there is a vent cap or drafthood (indoor) on top of the heater, remove it.

3.Remove all 8 hex-head screws fastening the top and lift the top assembly straight up (see Figure 12).

4.Remove rainshield assembly and set it aside.

5.Remove screws that fasten the gap closures to the jacket and put them aside. Remove gap closures.

6.Remove the screws securing the two flue collec- tor hold down clamps and remove the clamps (see Figure 13). Remove flue collector.

7.Remove the three rubber jacket/plug grommets and drain plugs (see Figure 12). One is located under the water connections on the right side. The other two are on the left side toward the front of the heater.

8.Tag and disconnect the white wire on the pressure switch (PS) and the white wire on the Fireman's switch terminal (see Figure 6 or 7) which leads to the high limit switch.

9.Remove plastic tie wraps and pull the white wires out of the front compartment through the vesti- bule cover and coil them on the heat exchanger.

10.Unscrew the brass compression fitting securing the pressure switch to the inlet/outlet header. Remove tube from header and gently bend it out of the way.

11.Loosen the screw securing the temperature sensing bulb retainer bracket. Slide the retainer bracket off the bulb flange and remove the bulb from the header

(see Figure 14). Pull pressure switch tube through the hole in the vestibule cover and into the vesti- bule (controls compartment), then pull thermostat bulb assembly through same hole (see Figure 15).

12.When removing the heat exchanger from the heater, the end baffles of the heat exchanger must be removed. There are two baffles covering part of the front and rear tubes of the heat exchanger. Each baffle is held in place by two screws which mount to the top of the combustion chamber wall. Remove the screws and the baffles before at- tempting to lift the heat exchanger out of the heater (see Figure 16).

Caution

It may be necessary to have help lifting the

heat exchanger out and replacing it.

HOLD DOWN

CLAMP

IN/OUT HEADER

BRACKET

Figure 13. Flue collector hold-down brackets.

Figure 14. Temperature sensing bulb.

(U.S. MODELS

 

ONLY)

 

LEFT

RIGHT

VESTIBULE

VESTIBULE

COVER

COVER

FRONT

PLASTIC BUSHING

Figure 15. Vestibule covers.

Image 13
Contents Outdoor Use Only Installation Laars Lite Pool and Spa HeaterTable of Contents 1A. Introduction Section2B. Field Assembly 1C. Warranty1B. Description 1D. Technical Assistance2C. Site Location 2C-1. Installation Information2C-3. Flooring Typical Installation 2C-2. Outdoor Installation2C-4. Indoor and Outdoor Shelter Installations United States2E. Gas Supply and Piping 2D. Combustion and Ventilation Air Supply2E-1. General Instructions 2E-2. Special Precautions for Propane Gas 2F. Electrical Wiring2F-1. General Information LD Only Model LD Wiring Diagram 92/7+$75,5,1*,$*5$0 2F-2. Auxiliary Time Clock Wiring2G. Water Flow System 2G-1. Flange Installation2F-3. Remote Operation Model LD Only 2G-2. Reversible Water Connections Piping installationFlue collector hold-down brackets 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals 2G-3. Check Valve Installation2G-4a. Water Chemistry 2G-6. Adjusting the Pressure Switch2G-5. Pressure Relief Valve 2G-7. Automatic Flow Control Valve 2G-8. Temperature Rise2G-9. Adjusting the Manual Bypass Valve Supply gas volume is too low3C. Setting the Temperature Control 3B. Lighting and Shutdown Procedures3A. General Information 3B-1. Model LD see 3B-2. Model LG seeReplace control access panel Service is to be performed Turn gas control knob clockwise Appliance switch to OFF3B-1. Model LD Direct Ignition Do not try to light any applianceWhat to do if YOU Smell GAS 3B-2. Model LG Standing Pilot3D-1. Spring and Fall Operation 3D. Seasonal Care3D-2. Winterizing 3D-3. Spring Start-up3E. Water Chemistry 3F. Spa/Hot Tub Safety Rules3G. Swimming Pool Energy Saving Tips 3H. Periodic Inspection 4B. Parts List4A. General Information 3H-1. Owner InspectionOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Limited Warranty