a) Model LD Temperature Control

b)Model LG Temperature Control

Figure 18. Temperature controls.

Figure 19. Pressure switch adjustment.

NOTE: Heater should not be allowed to fire on low speed.

4.Turn rotary switch (LD) or rocker switch (LG) to ON. Heater should start.

5.Pry out the top rubber dust plug on the top of the pressure switch.

6.Use a 7/32 inch (5.55 mm) Allen wrench to turn the adjustment screw very slowly clockwise until the heater goes off (see Figure 19).

7.Slowly turn the pressure switch adjustment screw counterclockwise one-quarter turn. The heater should come back on.

8.Check the adjustment by turning the filter pump OFF. The heater should shut off immediately. If it does not, restart the filter pump and repeat Steps 6 and 7. Check the adjustment again.

9.Return the pool temperature control to the desired temperature.

2G-7. Automatic Flow Control Valve

The automatic flow control valve maintains the proper flow through the heater at rates up to approxi- mately 125 Gallons Per Minute (GPM) (474 liters per minute [LPM]). If the system filter-flow rate is higher than approximately 125 GPM (474 LPM), install a manual bypass valve (see Figure 20), then perform a temperature rise test (see Section 2G-8) and adjust the flow using the bypass valve until the proper tempera- ture rise is obtained.

2G-8. Temperature Rise

A temperature rise test confirms proper water flow through the heater. The temperature rise is the difference between the temperature of the pool or spa water before and after heating, as measured in the header. Perform the following temperature rise test when the installation is complete:

1.Make sure the pool filter is clean.

2.Set the rotary switch (LD) or rocker switch (LG) on the temperature control panel (see Figure 18) to OFF.

3.Turn the filter pump off.

4.Remove the drain plug located on the inlet/outlet header of the heater and replace it with a Pete's plug (see Figure 17).

5.Insert a pocket thermometer (see Figure 17) through the Pete's plug into the header.

6.Turn the filter pump on and wait 3 minutes. The heater remains off. This allows water from the pool to reach the heater.

7.Record the temperature indicated by the ther- mometer (cold water).

8.Turn the heater ON following the lighting in- structions found on the inside of the heater.

9.Allow the heater to run for about 3 minutes. Record the new temperature reading (heated water).

10.Subtract the first temperature reading (cold water) from the second temperature reading (heated water). The difference between the two readings is the temperature rise. The temperature rise should be within the range shown in Table 6.

Table 6. Temperature Rise and Minimum Flow Rates

 

Minimum

Minimum

Maximum

 

 

 

 

 

 

 

Size

GPM

(LPM)

°F

(°C)

°F

(°C)

 

 

 

 

 

 

 

125

20

(76)

27

(15)

36

(20)

175

20

(76)

33

(19)

42

(24)

250

25

(95)

33

(19)

42

(24)

325

30

(114)

28

(16)

38

(21)

400

30

(114)

30

(17)

39

(22)

 

 

 

 

 

 

 

Image 16
Contents Installation Laars Lite Pool and Spa Heater Outdoor Use OnlyTable of Contents Section 1A. Introduction1C. Warranty 2B. Field Assembly1B. Description 1D. Technical Assistance2C-1. Installation Information 2C. Site Location2C-2. Outdoor Installation 2C-3. Flooring Typical Installation2C-4. Indoor and Outdoor Shelter Installations United States2E. Gas Supply and Piping 2D. Combustion and Ventilation Air Supply2E-1. General Instructions 2E-2. Special Precautions for Propane Gas 2F. Electrical Wiring2F-1. General Information LD Only Model LD Wiring Diagram 2F-2. Auxiliary Time Clock Wiring 92/7+$75,5,1*,$*5$02G. Water Flow System 2G-1. Flange Installation2F-3. Remote Operation Model LD Only Piping installation 2G-2. Reversible Water ConnectionsFlue collector hold-down brackets 2G-3. Check Valve Installation 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals2G-4a. Water Chemistry 2G-6. Adjusting the Pressure Switch2G-5. Pressure Relief Valve 2G-8. Temperature Rise 2G-7. Automatic Flow Control ValveSupply gas volume is too low 2G-9. Adjusting the Manual Bypass Valve3B. Lighting and Shutdown Procedures 3C. Setting the Temperature Control3A. General Information 3B-1. Model LD see 3B-2. Model LG seeTurn gas control knob clockwise Appliance switch to OFF Replace control access panel Service is to be performed3B-1. Model LD Direct Ignition Do not try to light any appliance3B-2. Model LG Standing Pilot What to do if YOU Smell GAS3D. Seasonal Care 3D-1. Spring and Fall Operation3D-2. Winterizing 3D-3. Spring Start-up3E. Water Chemistry 3F. Spa/Hot Tub Safety Rules3G. Swimming Pool Energy Saving Tips 4B. Parts List 3H. Periodic Inspection4A. General Information 3H-1. Owner InspectionOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Limited Warranty