3D. Seasonal Care

Caution

Do not operate this heater outdoors at

temperatures below 20 degrees Fahrenheit

(°F) (-7 degrees Celsius [°C]).

3D-1. Spring and Fall Operation

During periods when the pool is only going to be used occasionally, turn the temperature control down to the MIN setting. This prevents the pool from water from becoming chilled, and minimizes the time re- quired to raise the pool water back up to the desired temperature.

In areas subject to only short freeze periods, turn off the heater and run the pump continuously for the length of the freeze period.

If the heater is not going to be used for a long period of time, shut it down completely. Follow the instructions found on the inside of the heater, or pages 17(LD) or 18(LG) of this manual.

3D-2. Winterizing

In areas where freezing temperatures occur in winter, and the pool or spa will not be used, have your service technician perform the following steps:

1.Turn off the main gas supply valve to the heater, outside the heater jacket.

2.Remove heater door.

3.Shut down the heater following the shutdown instructions found on the inside of the heater.

4.Remove the drain plug from the return header (see Figure 21), loosen the drain plug from the inlet/outlet header, and completely drain the heater before the first frost.

5.After all water has drained from the heater, remove the drain plug from the inlet/outlet side. Check for mineral buildup in the openings.

6.Use compressed air to blow out any standing water remaining in the heat exchanger.

7.Grease the threads on the drain plugs and rein- stall plugs, but do not tighten.

8.Disconnect the pressure switch from the siphon loop (copper tubing) (see Figure 22).

3D-3. Spring Start-up

To restart the heater in the Spring, have a profes- sional service technician reassemble the heater as follows:

1.Fill the siphon loop with approximately 5cc of SAE 50, non-detergent oil. Attach the copper tubing to the pressure switch (see Figure 22).

2.Tighten the drain plugs.

3.Turn on the filter pump and circulate water through the heater for 5 minutes. Check for leaks while circulating.

4.Turn on the main gas supply valve to the heater, outside the heater jacket.

5.Turn on the heater following the lighting instruc- tions found on the inside of the heater, or pages 17(LD) or 18(LG) of this manual.

Figure 22. Pressure switch copper tubing.

Figure 21. Heater drain locations.

Image 21
Contents Outdoor Use Only Installation Laars Lite Pool and Spa HeaterTable of Contents 1A. Introduction Section2B. Field Assembly 1C. Warranty1B. Description 1D. Technical Assistance2C. Site Location 2C-1. Installation Information2C-3. Flooring Typical Installation 2C-2. Outdoor Installation2C-4. Indoor and Outdoor Shelter Installations United States2D. Combustion and Ventilation Air Supply 2E. Gas Supply and Piping2E-1. General Instructions 2F. Electrical Wiring 2E-2. Special Precautions for Propane Gas2F-1. General Information LD Only Model LD Wiring Diagram 92/7+$75,5,1*,$*5$0 2F-2. Auxiliary Time Clock Wiring2G-1. Flange Installation 2G. Water Flow System2F-3. Remote Operation Model LD Only 2G-2. Reversible Water Connections Piping installationFlue collector hold-down brackets 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals 2G-3. Check Valve Installation2G-6. Adjusting the Pressure Switch 2G-4a. Water Chemistry2G-5. Pressure Relief Valve 2G-7. Automatic Flow Control Valve 2G-8. Temperature Rise2G-9. Adjusting the Manual Bypass Valve Supply gas volume is too low3C. Setting the Temperature Control 3B. Lighting and Shutdown Procedures3A. General Information 3B-1. Model LD see 3B-2. Model LG seeReplace control access panel Service is to be performed Turn gas control knob clockwise Appliance switch to OFF3B-1. Model LD Direct Ignition Do not try to light any applianceWhat to do if YOU Smell GAS 3B-2. Model LG Standing Pilot3D-1. Spring and Fall Operation 3D. Seasonal Care3D-2. Winterizing 3D-3. Spring Start-up3F. Spa/Hot Tub Safety Rules 3E. Water Chemistry3G. Swimming Pool Energy Saving Tips 3H. Periodic Inspection 4B. Parts List4A. General Information 3H-1. Owner InspectionOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Limited Warranty