1.An Underwriters' Laboratories listed vent cap is required to prevent downdraft and allow the heater to function properly and safely.

2.Use approved roof jack.

Figure 2. Indoor Installation Venting (USA), or Outdoor Shelter (Canada).

Table 1. Air Openings to Outside.

Required Net Free Open Area for Combustion Air Openings

 

Direct from outside

Duct from outside

 

 

 

 

 

Model

in2

(cm2)

in2

(cm2)

125

32

(206)

64

(413)

 

 

 

 

 

175

44

(284)

88

(568)

 

 

 

 

 

250

63

(406)

126

(813)

325

82

(429)

164

(1058)

 

 

 

 

 

400

100

(645)

200

(1290)

 

 

 

 

 

Note: If using screens and/or louvers, compensate by adding 50% additional area to each opening.

When a drafthood is used, it must be connected to a vent pipe which stops at least 2 feet (0.61 meters [m]) above the highest point of the roof or other object that is within 10 feet (3.05 m) from the vent termina- tion. The vent pipe must have a listed vent cap which allows a full equivalent opening for flue products (see Figure 2).

2C. Site Location

WARNING

Improper installation or maintenance can cause nausea or asphyxiation from carbon monoxide in flue gases which could result in severe injury, or death.

2C-1. Installation Information

Avoid placing the heater in locations where it can cause damage by water or condensate leakage. If this is not possible, provide a suitable drain pan to catch and divert any leakage. The pan must not block natural flow of air around the heater.

Locate the heater so the clearances from combus- tible surfaces shown in Table 2 are met.

Table 2. Minimum Heater Clearances From Combustible Surfaces

 

Indoor (Outdoor Shelter) Installation

 

Outdoors Installation

 

U.S.

 

 

Canada

 

U.S.

 

Canada

Side of Heater

inch

(cm )

inch

( cm )

inch

(cm )

inch

(cm )

Blank

6

(15.2 )

6

(15.2 )

6

( 32 )

6

(15.2 )

Rear

6

(15.2 )

6

(15.2 )

6

( 32 )

6

(15.2 )

Piping

12

(30.5 )

18

(45.7 )

12

(30.5)

18

(45.7 )

Top

44

(111.7 )

44

(111.7 )

 

Open Unroofed Area

Front

18

(45.7 )

36

(91.4 )

18

(45.7 )

36

(91.4 )

Image 5
Contents Outdoor Use Only Installation Laars Lite Pool and Spa HeaterTable of Contents 1A. Introduction Section2B. Field Assembly 1C. Warranty1B. Description 1D. Technical Assistance2C. Site Location 2C-1. Installation Information2C-3. Flooring Typical Installation 2C-2. Outdoor Installation2C-4. Indoor and Outdoor Shelter Installations United States2E-1. General Instructions 2D. Combustion and Ventilation Air Supply2E. Gas Supply and Piping 2F-1. General Information LD Only 2F. Electrical Wiring2E-2. Special Precautions for Propane Gas Model LD Wiring Diagram 92/7+$75,5,1*,$*5$0 2F-2. Auxiliary Time Clock Wiring2F-3. Remote Operation Model LD Only 2G-1. Flange Installation2G. Water Flow System 2G-2. Reversible Water Connections Piping installationFlue collector hold-down brackets 2G-4. Chlorinators, Ozone Generators Sanitizing Chemicals 2G-3. Check Valve Installation2G-5. Pressure Relief Valve 2G-6. Adjusting the Pressure Switch2G-4a. Water Chemistry 2G-7. Automatic Flow Control Valve 2G-8. Temperature Rise2G-9. Adjusting the Manual Bypass Valve Supply gas volume is too low3C. Setting the Temperature Control 3B. Lighting and Shutdown Procedures3A. General Information 3B-1. Model LD see 3B-2. Model LG seeReplace control access panel Service is to be performed Turn gas control knob clockwise Appliance switch to OFF3B-1. Model LD Direct Ignition Do not try to light any applianceWhat to do if YOU Smell GAS 3B-2. Model LG Standing Pilot3D-1. Spring and Fall Operation 3D. Seasonal Care3D-2. Winterizing 3D-3. Spring Start-up3G. Swimming Pool Energy Saving Tips 3F. Spa/Hot Tub Safety Rules3E. Water Chemistry 3H. Periodic Inspection 4B. Parts List4A. General Information 3H-1. Owner InspectionOrder Heat Exchanger See Next page for Detail Shown Model LG & LD Pool and Spa Heater Limited Warranty