Pentair NT Standard Series installation manual Service CHECKS-IGNITION Module

Page 27

Troubleshooting—Normal Operation of Heater

27

 

 

POWER

 

 

 

 

 

 

SERVICE

 

 

 

 

 

 

 

CURRENT TEMP

 

SET TEMP/TIME

 

POOL OR SPA

 

 

 

 

 

 

(DISPLAY ALTERNATELY

 

 

 

 

 

 

ON LCD TO SHOW ACTIVE SELECTION)

 

 

 

 

 

 

IGN

H-LMT

PRESS

 

FAN

AUX

TFUSE

FAULT CONDITION LCD ICONS

 

 

 

 

 

 

SET

 

POOL

OFF

SPA

 

 

 

 

 

 

PROGRAM

 

 

 

STEP

 

SYSTEM NORMAL

HEAT

TEMP

MODE

TEMP

Figure 23.

Illustration of Pentair Temperature Controller 7800 with all fault icons displayed for clarity.

SERVICE CHECKS—IGNITION MODULE

Service Checks

Symptom

Cause/Cure

 

 

 

1.

Dead

A. Miswired

 

 

B. Transformer bad

 

 

C. Fuse/Circuit breaker bad

 

 

D.

Bad control (check LED for steady on)

 

 

 

 

2.

Thermostat on—no ignition

A.

Miswired

 

 

B. Bad thermostat no voltage at terminal W

 

 

 

 

3.

Valve on, no ignitor

A.

Defective ignitor

 

 

B.

Miswired

 

 

C. Bad control (check voltage at ignitor)

 

 

 

 

4.

Ignitor on, no valve

A.

Valve coil open

 

 

B. Open valve wire

 

 

C. Bad control (check voltage between V1 & V2)

 

 

 

 

5.

Flame okay during TFI,

A.

Bad ignitor

 

no flame sense (after TFI)

B.

Bad S1 wire

 

 

C. Poor ground at burner

 

 

D.

Poor flame (check flame current)

 

 

 

 

Rev. A 1-2-02

P/N 472032

Image 27
Contents For additional free copies of this manual call 800 MiniMax NT Standard SeriesTable of Contents Code Requirements MiniMax NT StandardWarranty Information Safety RulesOperation Operation Lighting For Your Safety Read Before LightingSpecifications Installation InstructionsELECTRICAL, for MiniMax NT Standard Heaters Installation ElectricalTWO-WIRE or THREE-WIRE Remote HOOK-UP Wire RemoteInstallation Remotes Three-wire remote Models HSI Electronic Installation DualWater Connections PlumbingPlumbing Connections GAS Connections Indoor VENTING-General Requirements Installation IndoorSee page 15 for Indoor Vent Adaptors Indoor Vent Adaptors Fits ALL Models Indoor InstallationVentilation Installation OutdoorGeneral Description Basic System OperationBasic Operation Typical Water Pressure Switch Safety ControlsAIR Pressure FAN Switch Water Pressure SwitchOperation of Ignition Module Normal Operation no Remote Minimax NT Standard Pentair Temperature ControllerGeneral Basic Thermostat OperationTo Change the Factory Temperature Settings Time SettingTemperature & Time Setting Programming Time Setting Programming Time SETTING, cont’dSpring and Fall Operation Maintenance InstructionsMaintenance Energy Saving TipsIf pH becomes too high over alkaline, it has these effects Maintenance Water TreatmentChemical Balance Pool and SPA WaterNormal Operation Sequence Troubleshooting-Normal Operation Sequence of HeaterTroubleshooting-Normal Operation of Heater Service CHECKS-IGNITION ModuleTroubleshooting & Service Heater Short Cycling Rapid On and Off Operation Troubleshooting GeneralMinimax NT Standard Heater Dual Voltage Description QTY MiniMax NT Standard Heaters Limited Warranty