Illustration of Pentair Temperature Controller 7800 with all fault icons displayed for clarity.
SERVICE CHECKS—IGNITION MODULE
Service Checks
Symptom | Cause/Cure | ||
|
|
| |
1. | Dead | A. Miswired | |
|
| B. Transformer bad | |
|
| C. Fuse/Circuit breaker bad | |
|
| D. | Bad control (check LED for steady on) |
|
|
|
|
2. | Thermostat | A. | Miswired |
|
| B. Bad thermostat no voltage at terminal W | |
|
|
|
|
3. | Valve on, no ignitor | A. | Defective ignitor |
|
| B. | Miswired |
|
| C. Bad control (check voltage at ignitor) | |
|
|
|
|
4. | Ignitor on, no valve | A. | Valve coil open |
|
| B. Open valve wire | |
|
| C. Bad control (check voltage between V1 & V2) | |
|
|
|
|
5. | Flame okay during TFI, | A. | Bad ignitor |
| no flame sense (after TFI) | B. | Bad S1 wire |
|
| C. Poor ground at burner | |
|
| D. | Poor flame (check flame current) |
|
|
|
|