Pentair NT Standard Series installation manual Description QTY

Page 31

 

 

 

 

 

 

 

31

 

 

 

MiniMax NT Standard Dual Voltage Replacement Parts

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

DESCRIPTION

QTY.

200

250

300

400

 

 

1

Exhaust Grill

1

 

471592

 

 

 

2

Gasket, Exhaust Grill

1

 

471701

 

 

 

3

Top Cover

1

471885

471692

471886

471591

 

 

4

Exhaust Assy.

1

472030

472040

472030

 

 

5

Shut-off Safety Switch, Exhaust

1

 

471714

 

 

 

6

Blower

1

471938

471883

471884

 

 

7

Gasket, Blower

1

 

471610

 

 

 

8

Flue Collector Assy.

1

472008

472007

472006

472005

 

 

9

Return Manifold Assy. Non-ASME

1

 

471991

 

 

 

10

Bolt, Heat Exchanger, Non-ASME

16

 

471622

 

 

 

11

Washer, Heat Exchanger

16

 

072184

 

 

 

12

Fire box Assy.

1

471904

471835

471922

471821

 

 

13

Heat Exchanger Assy. Non-ASME

1

471910

471785

471928

471838

 

 

14

Baffle, Heat Exchanger

8 / 16(200/250/300/400)

471642

471641

471896

471640

 

 

15

Thermistor Probe

1

 

471566

 

 

 

16

Hi-Limit Thermostat-115° F.

1

 

471587

 

 

 

17

Hi-Limit Thermostat-150° F.

1

 

471694

 

 

 

18

Water Pressure Switch

1

 

471672

 

 

 

19

Main Manifold Assy. Non-ASME

1

 

471993

 

 

 

20

Adapter, Bulkhead Ring

2

 

274440

 

 

 

21

Adapter, Bulkhead, 2 in.

2

 

471441

 

 

 

22

Gasket, Fin Tube, Seal

18

 

070951

 

 

 

23

Flow Valve Assy.

1

 

471750

 

 

 

24

Bracket, Gas Valve

1

 

471990

 

 

 

25

Orifice, Natural Gas, 0-2000 Ft.

4 / 5 / 6 / 8(200/250/300/400)

 

073727

 

 

 

Orifice, Propane, 0-2000 Ft.

 

073728

 

 

 

 

 

 

 

 

 

26

Gas Valve-Natural Gas

1

 

471601

 

 

 

Gas Valve-Propane

 

471671

 

 

 

 

 

 

 

 

 

27

Burner Tray Assy. Natural Gas

1

472042

472037

472033

472028

 

 

Burner Tray Assy. Propane

471907

471913

471925

471931

 

 

 

 

 

 

28

Igniter

1

 

471602

 

 

 

29

Gas Manifold Assy. Natural Gas

1

472023

472022

472021

472020

 

 

Gas Manifold Assy. Propane

472027

472026

472025

472024

 

 

 

 

 

 

30

Burner Only

2 / 3 / 4 / 6(200/250/300/400)

 

070230

 

 

 

Burner with Bracket

2

 

471970

 

 

 

 

 

 

 

 

31

Flame Sensor

1

 

471603

 

 

 

32

Jacket, Upper Panel, Left

1

 

471575

 

 

 

33

Jacket Corner

4

 

471581

 

 

 

34

Jacket Divider

1

471827

471651

471826

471580

 

 

35

Jacket, Lower Panel, Left

1

 

471647

 

 

 

36

Base

1

471829

471645

471828

471573

 

 

37

Jacket Back

1

471861

471669

471874

471574

 

 

38

Bracket, Jacket Side

2

 

471768

 

 

 

39

Jacket, Upper Panel, Right

1

 

471576

 

 

 

40

Jacket, Upper Subplate, Right

2

 

471767

 

 

 

41

Jacket, Lower Panel, Right

1

 

471577

 

 

 

42

Base Heat Shield

1

471831

471646

471830

471579

 

 

43

Control Box Assy.

1

 

472015

 

 

 

44

Air Pressure Switch

1

471747

471743

471897

471569

 

 

45

Module, Ignition Control

1

 

471893

 

 

 

46

Temperature Controller

1

 

471565

 

 

 

47

Right Door Assy.

1

 

471985

 

 

 

48

Left Door Assy.

1

471900

471659

471918

471726

 

 

49

Bracket, Front Burner Tray

1

471891

471656

471890

471630

 

 

50

Shield, Front Burner Tray

1

471821

471655

471805

471631

 

 

NA

Thermal Cut-off (Not Shown)

1

 

075173

 

 

Note: Some parts are not listed in above table, please contact our Customer Service Department for details.

Rev. A 1-2-02

P/N 472032

Image 31
Contents For additional free copies of this manual call 800 MiniMax NT Standard SeriesTable of Contents Code Requirements MiniMax NT StandardSafety Rules Warranty InformationOperation Operation Lighting For Your Safety Read Before LightingSpecifications Installation InstructionsELECTRICAL, for MiniMax NT Standard Heaters Installation ElectricalWire Remote TWO-WIRE or THREE-WIRE Remote HOOK-UPInstallation Remotes Three-wire remote Models HSI Electronic Installation DualPlumbing Water ConnectionsPlumbing Connections GAS Connections Indoor VENTING-General Requirements Installation IndoorSee page 15 for Indoor Vent Adaptors Indoor Vent Adaptors Fits ALL Models Indoor InstallationVentilation Installation OutdoorBasic System Operation General DescriptionBasic Operation Typical Water Pressure Switch Safety ControlsAIR Pressure FAN Switch Water Pressure SwitchOperation of Ignition Module Normal Operation no Remote Minimax NT Standard Pentair Temperature ControllerGeneral Basic Thermostat OperationTime Setting To Change the Factory Temperature SettingsTemperature & Time Setting Programming Time Setting Programming Time SETTING, cont’dSpring and Fall Operation Maintenance InstructionsMaintenance Energy Saving TipsIf pH becomes too high over alkaline, it has these effects Maintenance Water TreatmentChemical Balance Pool and SPA WaterNormal Operation Sequence Troubleshooting-Normal Operation Sequence of HeaterTroubleshooting-Normal Operation of Heater Service CHECKS-IGNITION ModuleTroubleshooting & Service Heater Short Cycling Rapid On and Off Operation Troubleshooting GeneralMinimax NT Standard Heater Dual Voltage Description QTY MiniMax NT Standard Heaters Limited Warranty