Installation (contd.)

20

 

 

Draft Hood

Top Cover

Adaptor

Screw

(2 PLC's)

HEATER

Figure 24.

INDOOR DRAFT HOOD INSTALLATION

1.Take out the louvered outer top piece after first removing the sheet metal screws, attaching it to the cabinet.

2.Install the adaptor (vent kit).

3.Install the top cover (vent kit).

4.Install the draft hood (vent kit).

Use the provided screws to secure the vent assembly.

ELECTRICAL, IID ELECTRONIC UNITS

Electrical Rating

 

60 Hz

115 V.A.C. or 230 V.A.C.

50/60 Hz

208 V.A.C. or 240 V.A.C.

NOTE

If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 AWG 105° C. U.L. approved AWM low energy stranded) copper wire or it's equivalent.

In Canada: wires must be CSA approved.

WARNING

The heater must be electrically grounded and bonded in accordance with local codes or, in the absence of local codes, with the latest national electrical codes ANSI/NFPA No. 70.

In Canada: CSA standard C22.1 Canada Electrical Code Part 1 and/or local codes.

Always use crimp type connectors when connecting two wires.

This heater is equipped with a reversible junction box to allow line voltage to be wired from either side.

Transformer Wiring Instruction

Figure 26.

Figure 25.

P/N 471048

Rev. G 1-22-04

Image 20
Contents For additional free copies of this manual call 800 For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Table of Contents Code Requirements Important NoticesOperation contd Warranty InformationSafety Rules To Turn OFF GAS to Appliance For Your Safety Read Before LightingOperating Instructions Safety Lockout Minimax Plus Electronic Ignition LIGHTING/OPERATION PropaneLighting Instructions What to do if YOU Smell GASIndicator Light Description Operating ControlsTroubleshooting Controls Heat HeatTroubleshooting Controls Maintenance Instructions Energy Saving TipsSpring and Fall Operation Winter OperationChemical Balance Pool and SPA WaterIf pH becomes too high over alkaline, it has these effects Alkalinity High LowInstallation Instructions SpecificationsPlumbing Connections Water ConnectionsPlumbing QUICK-FLANGE Installation Instructions For 1½ & 2 in. Copper PipeGAS Line Installations GAS ConnectionsVentilation Outdoor Installation onlyOutdoor Vent CAP Installation Front MiniMax heaters, including PowerMax versions Stack Type Indoor Draft Hood KITIndoor Draft Hood Installation Transformer Wiring InstructionMiniMax Plus Electronic Installation contd Ignition Wiring DiagramMiniMax Plus Millivolt Wiring Diagram Wire RemoteHeater exchanger scaled Heater Short Cycling Rapid On and Off OperationMinimax Plus Heater ALL Models MiniMax Plus Only Parts List Description QTYMiniMax Plus Only Parts List, contd Description QTYPowerMax Pool & Spa Heater Code Requirements General SpecificationIntroduction Mounting Assembly Venting Indoor Installations Powermax Venting Guidelines Outdoor Installation Powermax Venting Guidelines 22-04 Rev. G Wiring Diagram for Powermax KIT Powermax Heater ALL Models PowerMax Heater Only Parts List Description QTYPowerMax Heater Only Parts List, contd Description QTYPowerMax Assembly Parts List PowerMax AssemblyPentair Pool Products, Inc
Related manuals
Manual 36 pages 41.25 Kb

100 specifications

Pentair 100 is an advanced water filtration system designed to address a variety of water purification needs for residential and commercial applications. Renowned for its efficiency and reliability, the Pentair 100 incorporates cutting-edge technologies that enhance the quality of water while ensuring ease of use.

One of the standout features of the Pentair 100 is its multi-stage filtration process. This system utilizes a combination of sediment filters, activated carbon filters, and advanced membrane technology to remove impurities including bacteria, viruses, heavy metals, and chlorine. The sediment filter captures larger particles, while the activated carbon filter removes organic compounds and improves taste and odor. The membrane technology employed in the system further refines the water by filtering out microscopic contaminants, ensuring purity.

The Pentair 100 is equipped with an innovative monitoring system that allows users to track filter performance and maintenance needs in real time. This feature is designed to optimize the lifespan of the filters and ensure that the system operates at maximum efficiency. Additionally, the intuitive LED indicators provide clear notifications regarding filter replacements and system status, simplifying the upkeep of the filtration unit.

Sustainability is another core aspect of the Pentair 100. The system is designed to reduce water wastage, making it an environmentally friendly option for consumers. Its efficient filtration process minimizes the need for bottled water, contributing to reduced plastic waste. Furthermore, the materials used in the construction of the unit are durable and recyclable, aligning with contemporary green initiatives.

The compact design of the Pentair 100 makes it suitable for various setups, whether it is for a small apartment or a larger commercial space. Installation is straightforward, with flexible options for under-sink or point-of-use configurations. This versatility extends to its compatibility with existing plumbing systems, allowing for seamless integration.

In summary, the Pentair 100 embodies advanced filtration technologies, sustainable operations, and user-friendly features, making it an excellent choice for anyone looking to improve their water quality. Its robust performance, combined with smart monitoring capabilities, ensures that users have access to safe and delicious water while promoting environmental responsibility. Whether for everyday use or special needs, the Pentair 100 stands out as a premier solution in the water filtration market.