Pentair 100 installation manual Front

Page 18

Installation (contd.)

18

 

 

INDOOR INSTALLATION (USA ONLY) OUTDOOR SHELTER INSTALLATION (CANADA)

(See additional instructions for outdoor PowerMax units in PowerMax Appendix)

All products of combustion and vent gases must be completely removed to the outside atmosphere through a vent pipe which is connected to the draft hood. A vent pipe extension of the same size must be connected to the draft hood and extended at least 2 feet higher than highest point of the roof within a 10 foot horizontal radius, and at least 3 ft. higher than the point at which it passes through the roof, or as permitted by local code; see Figures 21 and 22. The vent should terminate with an approved vent cap (weather cap) for protection against rain or blockage by snow. Double-wall vent pipe and an approved roof jack shall be employed through the roof penetration. The use of double-walled type B vent pipe is recommended.

The draft hood must be installed so as to be in the same atmospheric pressure zone as the combustion air inlet to the pool heater. The certified (factory) draft hood must not be modified in any way and must be employed in every indoor installation (with the exception of the PowerMax units).

The heater must be located as close as practical to a chimney or gas vent. The heater should be installed at least 5 feet away from the pool or spa.

The heater must be placed in a suitable room on a non-combustible floor or on a non-combustible base and in an area where leakage from heat exchanger or water connections will not result in damage to the area adjacent to the heater or the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan with adequate drainage, be installed under the heater. The pan must not restrict air flow.

P/N 471048

Installations in basements, garages, or underground structures where flammable liquids may be stored must have the heater elevated 18 inches from the floor using a non-combustible base. The following minimum clearances from combustible materials must be provided.

 

Side

Front

Back

Top

Water Connection

18 in.

24 in.

 

 

Remaining

6 in.

 

6 in.

 

Ceiling Clearance

 

 

 

36 in.*

*To ceiling or roof.

 

 

 

 

Vent terminated at least 24 in. above any object within 10 ft.

10 ft.

Vent

Ridge

Cap

 

2 ft. min.

 

3 ft. min.

 

 

Roof

 

Jack

Chimney

Figure 21.

Vent Cap and Riser Furnished by Installer

* Rise

Air Supply

 

 

Ventilation

Air Supply

* 1” Rise Per FootGas Combustion

Recommended

Figure 22.

Rev. G 1-22-04

Image 18
Contents For Your Safety Read Before Operating What to do if YOU Smell GASFor additional free copies of this manual call 800 Table of Contents Code Requirements Important NoticesWarranty Information Safety RulesOperation contd For Your Safety Read Before Lighting Operating InstructionsTo Turn OFF GAS to Appliance Safety Lockout Minimax Plus Electronic Ignition LIGHTING/OPERATION PropaneLighting Instructions What to do if YOU Smell GASIndicator Light Description Operating ControlsTroubleshooting Controls Heat HeatTroubleshooting Controls Spring and Fall Operation Maintenance InstructionsEnergy Saving Tips Winter OperationIf pH becomes too high over alkaline, it has these effects Chemical BalancePool and SPA Water Alkalinity High LowInstallation Instructions SpecificationsWater Connections PlumbingPlumbing Connections QUICK-FLANGE Installation Instructions For 1½ & 2 in. Copper PipeGAS Line Installations GAS ConnectionsOutdoor Installation only Outdoor Vent CAP InstallationVentilation Front MiniMax heaters, including PowerMax versions Stack Type Indoor Draft Hood KITIndoor Draft Hood Installation Transformer Wiring InstructionMiniMax Plus Electronic Installation contd Ignition Wiring DiagramMiniMax Plus Millivolt Wiring Diagram Wire RemoteHeater exchanger scaled Heater Short Cycling Rapid On and Off OperationMinimax Plus Heater ALL Models MiniMax Plus Only Parts List Description QTYMiniMax Plus Only Parts List, contd Description QTYPowerMax Pool & Spa Heater General Specification IntroductionCode Requirements Mounting Assembly Venting Indoor Installations Powermax Venting Guidelines Outdoor Installation Powermax Venting Guidelines 22-04 Rev. G Wiring Diagram for Powermax KIT Powermax Heater ALL Models PowerMax Heater Only Parts List Description QTYPowerMax Heater Only Parts List, contd Description QTYPowerMax Assembly Parts List PowerMax AssemblyPentair Pool Products, Inc
Related manuals
Manual 36 pages 41.25 Kb

100 specifications

Pentair 100 is an advanced water filtration system designed to address a variety of water purification needs for residential and commercial applications. Renowned for its efficiency and reliability, the Pentair 100 incorporates cutting-edge technologies that enhance the quality of water while ensuring ease of use.

One of the standout features of the Pentair 100 is its multi-stage filtration process. This system utilizes a combination of sediment filters, activated carbon filters, and advanced membrane technology to remove impurities including bacteria, viruses, heavy metals, and chlorine. The sediment filter captures larger particles, while the activated carbon filter removes organic compounds and improves taste and odor. The membrane technology employed in the system further refines the water by filtering out microscopic contaminants, ensuring purity.

The Pentair 100 is equipped with an innovative monitoring system that allows users to track filter performance and maintenance needs in real time. This feature is designed to optimize the lifespan of the filters and ensure that the system operates at maximum efficiency. Additionally, the intuitive LED indicators provide clear notifications regarding filter replacements and system status, simplifying the upkeep of the filtration unit.

Sustainability is another core aspect of the Pentair 100. The system is designed to reduce water wastage, making it an environmentally friendly option for consumers. Its efficient filtration process minimizes the need for bottled water, contributing to reduced plastic waste. Furthermore, the materials used in the construction of the unit are durable and recyclable, aligning with contemporary green initiatives.

The compact design of the Pentair 100 makes it suitable for various setups, whether it is for a small apartment or a larger commercial space. Installation is straightforward, with flexible options for under-sink or point-of-use configurations. This versatility extends to its compatibility with existing plumbing systems, allowing for seamless integration.

In summary, the Pentair 100 embodies advanced filtration technologies, sustainable operations, and user-friendly features, making it an excellent choice for anyone looking to improve their water quality. Its robust performance, combined with smart monitoring capabilities, ensures that users have access to safe and delicious water while promoting environmental responsibility. Whether for everyday use or special needs, the Pentair 100 stands out as a premier solution in the water filtration market.