Pentair 100 installation manual MiniMax Plus Only Parts List, Description QTY

Page 25

25

MiniMax Plus (Only) Parts List

ITEM

DESCRIPTION

QTY

150

195/200

250

300

350

400

1

Vent kit assy. (indoor)

1

460227

460228

460230

460231

460233

460234

 

 

 

 

 

 

 

 

 

1a

Vent kit assy. (outdoor)

1

460237

460222

460223

460224

460225

460226

 

 

 

 

 

 

 

 

 

2

Return header

1

070994

070994

070994

070994

070994

070994

 

 

 

 

 

 

 

 

 

3

Bracket washer

2

074216

074216

074216

074216

074216

074216

 

 

 

 

 

 

 

 

 

4

Bolt HH 3/8" x 2"

4

073739

073739

073739

073739

073739

073739

 

 

 

 

 

 

 

 

 

5

Bolt 3/8" - 16 x 1 1/2"

4

070416

070416

070416

070416

070416

070416

 

 

 

 

 

 

 

 

 

6

Washer 3/8" ID 1" OD

4

072180

072180

072180

072180

072180

072180

 

 

 

 

 

 

 

 

 

7

Tube seal gasket

18

070951

070951

070951

070951

070951

070951

 

 

 

 

 

 

 

 

 

8

Transformer - w/circuit breaker - dual voltage

1

471360

471360

471360

471360

471360

471360

 

 

 

 

 

 

 

 

 

9

ElectronicThermostat circuit board - IID Models

1

470179

470179

470179

470179

470179

470179

 

 

 

 

 

 

 

 

 

10

Module natural gas

1

073584

073584

073584

073584

073584

073584

 

 

 

 

 

 

 

 

 

Module propane gas

1

073585

073585

073585

073585

073585

073585

 

 

 

 

 

 

 

 

 

11

Junction Box (IID Units)

1

470122

470122

470122

470122

470122

470122

 

 

 

 

 

 

 

 

 

12

Thermostat knob

2

470184

470184

470184

470184

470184

470184

 

 

 

 

 

 

 

 

 

13

Switch rocker (single pole & double throw)

1

470186

470186

470186

470186

470186

470186

 

 

 

 

 

 

 

 

 

 

Control panel assy. (complete) - IID Nat

1

470295

470296

470297

470298

470299

470187

 

 

 

 

 

 

 

 

 

14

Control panel assy. (complete) - IID Pro

1

470987

470988

470989

470990

470991

470992

 

 

 

 

 

 

 

 

 

 

Control panel assy. (complete) - Millivolt

1

471020

471021

471022

471023

471024

471025

 

 

 

 

 

 

 

 

 

15

Door - IID or Millivolt

1

075468

075604

075488

075605

075606

075490

 

 

 

 

 

 

 

 

 

16

Manifold burner

1

070256

075525

070257

075526

075527

070258

 

 

 

 

 

 

 

 

 

 

Gas valve natural - IID

1

073998

073998

073998

073998

073998

073998

 

 

 

 

 

 

 

 

 

17

Gas valve propane- IID

1

073999

073999

073999

073999

073999

073999

 

 

 

 

 

 

 

 

 

Gas valve natural - Millivolt

1

075457

075457

075457

075457

075457

075457

 

 

 

 

 

 

 

 

 

 

Gas valve propane - Millivolt

1

075458

075458

075458

075458

075458

075458

 

 

 

 

 

 

 

 

 

18

Pilot tube - IID

1

075191

075191

075192

075192

075193

075193

 

 

 

 

 

 

 

 

 

Pilot tube - Millivolt

 

076084

076084

076085

076085

076086

076086

 

 

 

 

 

 

 

 

 

 

Burner tray assy. natural (complete) - IID

1

073752

075499

073751

075500

075501

073750

 

 

 

 

 

 

 

 

 

19

Burner tray assy. propane (complete) - IID

1

073906

075508

073905

075509

075510

073904

 

 

 

 

 

 

 

 

 

Burner tray assy. natural (complete) - Millivolt

1

075493

075496

075494

075497

075498

075495

 

 

 

 

 

 

 

 

 

 

Burner tray assy. propane (complete) - Millivolt

1

075502

075505

075503

075506

075507

075504

 

 

 

 

 

 

 

 

 

 

 

 

2 EA.

3 EA.

4 EA.

5 EA.

6 EA.

7 EA.

20

Burner

 

070230

070230

070230

070230

070230

070230

 

 

 

 

 

 

 

 

 

20a

Burner with Pilot Bracket

1

470550

470550

470550

470550

470550

470550

 

 

 

 

 

 

 

 

 

21

Pressure switch

1

470190

470190

470190

470190

470190

470190

 

 

 

 

 

 

 

 

 

22

Combustion chamber assy. (complete)

1

073858

075586

073857

075587

075588

073856

 

 

 

 

 

 

 

 

 

23

Valve drain 3/4"

1

072134

072134

072134

072134

072134

072134

 

 

 

 

 

 

 

 

 

24

Presslite igniter assy. (Millivolt Units only)

1

075459

075459

075459

075459

075459

075459

 

 

 

 

 

 

 

 

 

25

Valve relief 3/4" 50# - ASME or Local Code

1

072138

072138

072138

072138

072138

072138

 

 

 

 

 

 

 

 

 

26

Potentiometer (Millivolt Units only)

2

471678

471678

471678

471678

471678

471678

 

 

 

 

 

 

 

 

 

27

Flow valve assy., Standard (complete)

1

471424

471424

471424

471424

471424

471424

 

 

 

 

 

 

 

 

Flow valve assy., ASME (complete)

1

073989

073989

073989

073989

073989

073989

 

 

 

 

 

 

 

 

 

 

28

Flow valve gasket

4

074015

074015

074015

074015

074015

074015

 

 

 

 

 

 

 

 

 

29

Bolt 3/8" - 16 x 2 1/2

2

075492

075492

075492

075492

075492

075492

 

 

 

 

 

 

 

 

 

30

Quick flange Kit

1

075284

075284

075284

075284

075284

075284

 

 

 

 

 

 

 

 

 

Rev. G 1-22-04

P/N 471048

Image 25
Contents What to do if YOU Smell GAS For Your Safety Read Before OperatingFor additional free copies of this manual call 800 Table of Contents Important Notices Code RequirementsSafety Rules Warranty InformationOperation contd Operating Instructions For Your Safety Read Before LightingTo Turn OFF GAS to Appliance Minimax Plus Electronic Ignition LIGHTING/OPERATION Propane Safety LockoutWhat to do if YOU Smell GAS Lighting InstructionsOperating Controls Indicator Light DescriptionHeat Heat Troubleshooting ControlsTroubleshooting Controls Energy Saving Tips Maintenance InstructionsSpring and Fall Operation Winter OperationPool and SPA Water Chemical BalanceIf pH becomes too high over alkaline, it has these effects Alkalinity High LowSpecifications Installation InstructionsPlumbing Water ConnectionsPlumbing Connections For 1½ & 2 in. Copper Pipe QUICK-FLANGE Installation InstructionsGAS Connections GAS Line InstallationsOutdoor Vent CAP Installation Outdoor Installation onlyVentilation Front Stack Type Indoor Draft Hood KIT MiniMax heaters, including PowerMax versionsTransformer Wiring Instruction Indoor Draft Hood InstallationIgnition Wiring Diagram MiniMax Plus Electronic Installation contdWire Remote MiniMax Plus Millivolt Wiring DiagramHeater Short Cycling Rapid On and Off Operation Heater exchanger scaledMinimax Plus Heater ALL Models Description QTY MiniMax Plus Only Parts ListDescription QTY MiniMax Plus Only Parts List, contdPowerMax Pool & Spa Heater Introduction General SpecificationCode Requirements Mounting Assembly Venting Indoor Installations Powermax Venting Guidelines Outdoor Installation Powermax Venting Guidelines 22-04 Rev. G Wiring Diagram for Powermax KIT Powermax Heater ALL Models Description QTY PowerMax Heater Only Parts ListDescription QTY PowerMax Heater Only Parts List, contdPowerMax Assembly PowerMax Assembly Parts ListPentair Pool Products, Inc
Related manuals
Manual 36 pages 41.25 Kb

100 specifications

Pentair 100 is an advanced water filtration system designed to address a variety of water purification needs for residential and commercial applications. Renowned for its efficiency and reliability, the Pentair 100 incorporates cutting-edge technologies that enhance the quality of water while ensuring ease of use.

One of the standout features of the Pentair 100 is its multi-stage filtration process. This system utilizes a combination of sediment filters, activated carbon filters, and advanced membrane technology to remove impurities including bacteria, viruses, heavy metals, and chlorine. The sediment filter captures larger particles, while the activated carbon filter removes organic compounds and improves taste and odor. The membrane technology employed in the system further refines the water by filtering out microscopic contaminants, ensuring purity.

The Pentair 100 is equipped with an innovative monitoring system that allows users to track filter performance and maintenance needs in real time. This feature is designed to optimize the lifespan of the filters and ensure that the system operates at maximum efficiency. Additionally, the intuitive LED indicators provide clear notifications regarding filter replacements and system status, simplifying the upkeep of the filtration unit.

Sustainability is another core aspect of the Pentair 100. The system is designed to reduce water wastage, making it an environmentally friendly option for consumers. Its efficient filtration process minimizes the need for bottled water, contributing to reduced plastic waste. Furthermore, the materials used in the construction of the unit are durable and recyclable, aligning with contemporary green initiatives.

The compact design of the Pentair 100 makes it suitable for various setups, whether it is for a small apartment or a larger commercial space. Installation is straightforward, with flexible options for under-sink or point-of-use configurations. This versatility extends to its compatibility with existing plumbing systems, allowing for seamless integration.

In summary, the Pentair 100 embodies advanced filtration technologies, sustainable operations, and user-friendly features, making it an excellent choice for anyone looking to improve their water quality. Its robust performance, combined with smart monitoring capabilities, ensures that users have access to safe and delicious water while promoting environmental responsibility. Whether for everyday use or special needs, the Pentair 100 stands out as a premier solution in the water filtration market.