Sony MDS-JE770 specifications Traverse Adjustment, Iop NV Save

Page 32

MDS-JE770

7.Then, rotate the lAMS L knob and display “LDPWR CHECK”(C13).

8. Press the YES button once and display “LD 0.9 mW $ ”. Check that the reading of the laser power meter become the speci- fied value.

9.Press the YES button once more and display “LD 7.0 mW $

”. Check that the reading the laser power meter and digital volt meter satisfy the specified value.

Note down the digital voltmeter reading value.

Specified Value :

Laser power meter reading : LD 0.9mW : 0.85-0.91mW (260B) 0.90-0.96mW (260E)

LD 7.0mW : 6.90-7.10mW (260B) 7.20-7.30mW (260E)

Digital voltmeter reading : Optical pick-up displayed value ± 10%

(Optical pick-up label)

KMS260B

(For details of the method for checking

20101

this value, refer to “5-8. Recording and

Displaying IOP Information”.)

H0576

 

 

 

R

 

Iop = 57.6 mA in this case

Iop (mA) = Digital voltmeter reading (mV)/1 ()

10.Press the MENU/NO button and display “LDPWR CHECK” (C13) and stop the laser emission.

(The MENU/NO button is effective at all times to stop the laser emission.)

11.Rotate the lAMS L knob to display “Iop.Write”(C05).

12.Press the YES button. When the display becomes Ref = @@@

.@ (@ is an arbitrary number), press the YES button to display “Measu=@@@.@” (@ is an arbitrary number).

13.The numbers which can be changed will blink. Input the Iop value noted down at step 9.

To select the number : Rotate the lAMS L knob.

To select the digit : Press the lAMS L knob

14.When the YES button is pressed, “Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop Write”(C05).

Note 1: After step 4, each time the YES button is pressed, the display will be switched between “LD 0.7 mW $ ”, “LD

6.2mW $ ”, and “LD Wp $ ”. Nothing needs to be performed here.

5-11. Iop NV SAVE

Write the reference values in the nonvolatile memory to perform “Iop compare”. As this involves rewriting the reference values, do not perform this procedure except when adjusting the laser power during replacement of the OP and when replacing the IC102. Otherwise the OP check may deteriorate.

Note: Perform this function with the optical pick-up set at room temperature.

Procedure

1.Rotate the l AMS L knob to display “Iop NV Save” (C06).

2.Press the YES button and display “Iop [stop]”.

3.After the display changes to “Iop =xxsave?”, press the YES button.

4.After “Complete!” is displayed momentarily, the display changes to “Iop 7.0 mW”.

5.After the display changes to “Iop=yysave?”, press the YES button.

6.When “Complete!” is displayed, it means that Iop NV saving has been completed.

5-12. TRAVERSE ADJUSTMENT

Connection :

Oscilloscope

BD board

CN105 pin 4 (TE)

CN105 pin 6 (VC)

V : 0.5 V/div

H : 10 ms/div

Input : DC mode

Adjusting Procedure :

1.Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin 6 (VC) of the BD board.

2.Load a test disc (MDW-74/GA-1). (Refer to Note 1.)

3.Press the M button and move the optical pick-up outside the pit.

4.Rotate the l AMS L knob and display “EF MO ADJUS”(C07).

5.Press the YES button and display “EFB = MO-R”.

(Laser power READ power/Focus servo ON/tracking servo OFF/ spindle (S) servo ON)

6.Rotate the lAMS L knob so that the waveform of the oscilloscope becomes the specified value.

(When the lAMS L knob is rotated, the of “EFB=

” changes and the waveform changes.) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the wave- form so that the specified value is satisfied as much as possible. (Read power traverse adjustment)

(Traverse Waveform)

A

VC

B

Specification A = B

7.Press the YES button and save the result of adjustment to the non-volatile memory (“EFB = SAVE” will be displayed for a moment. Then “EFB = MO-W” will be displayed).

8.Rotate the lAMS L knob so that the waveform of the oscilloscope becomes the specified value.

(When the lAMS L knob is rotated, the of “EFB- MO-W” changes and the waveform changes.) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the wave- form so that the specified value is satisfied as much as possible. (Write power traverse adjustment)

(Traverse Waveform)

A

VC

B

Specification A = B

9.Press the YES button, and save the adjustment results in the non-volatile memory. (“EFB = SAVE” will be displayed for a moment.)

10.“EFB = MO-P”. will be displayed.

The optical pick-up moves to the pit area automatically and servo is imposed.

32

Image 32
Contents Specifications 873-890-11MDS-S50 MDM-7AGenera l Power requirements Supplied accessoriesMDS-JE770 SELF-DIAGNOSIS FunctionItems of Error History Mode Items and Contents Table of Contents DisassemblyDiagrams Exploded ViewsMDS-JE770 Section Service Notes Flexible Circuit Board RepairingJIG for Checking BD Board Waveform IOPRecord Precedure KSN-260E Optical PICK-UP Block Type DiscriminationMain Board Component Side Checks Prior to Parts Replacement and AdjustmentsForced Reset Retry Cause Display Mode Bit BinaryHexadecimal Binary Bit When BinaryHigher Bits Lower Bits Hexa Details MDS-JE770 Section General Button DescriptionsMDS-JE770 Section Disassembly Disassembly FlowFront Panel Section Main Board Two screwsMechanism Deck Section MDM-7A Over Light Head HR901, BD BoardHolder Assy Loading Motor Assy M103Sled Motor Assy M102, Slider Optical PICK-UPSpindle Moter Assy M101 MDS-JE770 Section Test Mode Precautions for USE of Test ModeSetting the Test Mode Exiting the Test ModeSelecting the Test Mode Operating the Continuous Playback Mode MENU/NOTest Mode Displays Mode displayError rate display Functions of Other ButtonsWhen Memory NG is Displayed Meanings of Other DisplaysAutomatic SELF-DIAGNOSIS Function InformationCheck before replacement MDS-JE770 Section Electrical AdjustmentsParts Replacement and Adjustment Adjustment flow Auto Gain Control Output LevelPrecautions for Checking Laser Diode Emission Precautions for USE of Optical PICK- UP KMS-260B/260EPrecautions for Adjustments Temp AdjustUsing the Continuously Recorded Disc Checks Prior to RepairsAuto Check Other ChecksTraverse Check Traverse WaveformPlay Check MO Error Rate Check CD Error Rate CheckFocus Bias Check Self-Recording/playback CheckLaser Power Adjustment Initial Setting of Adjustment ValueTemperature Compensation Offset Adjutment Traverse Adjustment Iop NV SaveFocus Bias Adjustment Error Rate Check Auto Gain Control Output Level AdjustmentCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points MDS-JE770 Section Diagrams Circuit Boards LocationFor schematic diagrams For printed wiring boardsBD Board Main BoardIC190 Block Diagrams BD SectionIC171 IC1 2/2 Main SectionIC360 2/2 SemiconductorOVER SemiconductorOptical Pick UP Block Write HeadBoard Board Main Main Schematic Diagram Main /2 See page 51 for IC Block Diagrams Model is printed on diagram IC1Display Board KB BoardKEY-SW Board HP BoardSchematic Diagram Display Section LED DriveRY910 C951 C952D910 CN921 C924 LF900 C910Schematic Diagram Power Section MainIC Block Diagrams IC101 CXA2523AR BD BoardIC500 AK4524 Main Board Pin No Pin Name Description IC PIN Function DescriptionIC101 CXA2523AR RF Amplifier BD Board Pin No Pin Name Desription Mvci AsyoAsyi AvddTfdr FfdrFrdr FS4IIC Power ADA.RESETFldt FlckADA. Latch EPNDINT1/H Clip ProtectTimer STBBeep SW REC FlcsReset VDISP1VFL1 OSC0Section Exploded Views Chassis SectionFL750 1-517-987-11 Indicator TUBE, Fluorescent Not supplied Supplied with J790 FL750 With RV790Mechanism MDM-7A HEAD, Over Light Motor ASSY, SpindleMotor ASSY, Sled Motor ASSY, LoadingMDS-JE770 Section Electrical Parts List Switch Metal ChipJumper Resistor ShortMDS-JE770 Display HP KB KEY-SW KEY-SW Main MDS-JE770 Main 2SD2144S-TP-UVW Resistor MDS-JE770 Main PT VOL-SELMemo MDS-JE770 Revision History