AquaPRO APB075PRO, APB250UPRO, APB150PRO, APB300PRO, APB100UPRO Pool Safety Guidelines, Installation

Page 3

Manual del usuario

APB075PRO, APB100PRO, APB150PRO, APB200PRO, APB300PRO, APB100UPRO, APB150UPRO, APB200UPRO and APB250UPRO

Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Distribuidor Más Cercano a Su Domicilio

Sírvase darnos la siguiente información:

Dirija toda la correspondencia a:

- Número del modelo

AquaPRO® Systems

- Número de Serie o código con fecha (de haberlo)

Attn: Customer Service

- Descripción y número del repuesto según la lista

101 Production Drive

de repuestos

Harrison, OH 45030 U.S.A.

14

15

6

10

 

 

12

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

4

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

7

16

19

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

21

 

9

18

8b

 

1

8a

 

2

 

20

 

13

General Safety Information (Cont.)

or pump house must allow adequate ventilation to assure the ambient temperature remains below the motor rating when the pump is operating.

Locate pump on a non combustible surface. The surface should be hard, level, dry, well ventilated, out of direct sunlight. The surrounding area should provide protection from the elements and allow sufficient space for maintenance and service. Ensure the drainage will flow away from the pump. To reduce vibration and pipe stress, use anchor bolts to secure pump base to surface. Support the suction and discharge piping.

Design the piping system to allow the pump suction inlet height to be as close to water level as possible. Mount pump below water level for easy priming. If the pump must be located above the filled water level, keep the vertical distance to a minimum. Use short, direct piping to the suction this will minimize friction loss.

Fire and burn hazard. Motors run at high

temperatures. Do not allow leaves, debris, or foreign matter to collect around the pump motor. Keep ventilation holes open. Allow motor to cool before handling. Keep flammable liquids away.

If the thermal overload protection in the motor trips or if the GFCI trips determine the reason and correct the problem before re-starting pump.

Use rigid or flexible PVC pipe. Ensure pipe ends are clean and free of any flash caused by cutting. Use the proper glue for the type of pipe selected.

NOTE: Use a supplier recommended primer to ensure glued joints are secure. Many local codes require primer with a purple tracer to verify primer use.

Consider climatic conditions when applying adhesives. Atmospheric conditions with high humidity will make the adhesive action of certain glues less effective. Follow the manufacturer’s instructions.

Pool Safety Guidelines

RESPONSIBLE ADULT SUPERVISION

Constant and responsible adult supervi- sion is mandatory in the pool or spa environment. Always supervise children around pools and spas. Never allow a child to play in a way that could permit the child’s hair to come near the drain cover.

DRAINS, SUCTION FITTINGS, AND JETS

Keep hair and clothing away from the suc- tion fitting drain cover. Wear a bathing cap or pin hair up if you have long hair. Current grates and covers help prevent body or hair entrapment. Make sure that drain covers meet the ANSI/ASME A112.19.8 standard. Safety doors should be installed in all pool cleaner wall suction lines. Pools or spas with drain covers that are broken, missing, or not adequately secured should not be used until the proper replacement has been installed.

ELECTRICAL HAZARDS

A licensed electrician, experienced in swimming pools and spas, should inspect your equipment to make sure everything is properly grounded, bonded, and pro- tected by proper GFCI circuits according to Article 680 of the National Electric Code.

DROWNING PREVENTION

Install and routinely inspect fences, self-clos- ing and latching gates, baby barrier fences, and alarms. Eliminate incidental routes to pool including machinery or equipment that provides a route over fencing into pool area.

INDOOR INSTALLATIONS

Pools and spas located indoors must comply with ANSI/ASHRAE (American Society of Heating, Refrigeration and Air-Conditioning Engineers) standard 62-2001 to ensure adequate ventilation and safe use.

WARNING SIGNS

Protect your family and guests. Make sure that all warning signs provided by the manufacturer, builder, or installer are displayed according to the manufac- turer’s specifications.

Installation

Shock Hazard! Only qualified, licensed

personnel should install pump and wiring.

Aprofessional trained and familiar

with pool pump installation must perform pressure tests.

Figure 2

www.aquaprosystems.com

22 Sp

3

Image 3
Contents AquaPRO Systems Manual del usuarioNº DE Modelo Nº DE Serie Fecha DE Instalación 24 SpLista de Repuestos ContentsSafety Guidelines General Safety InformationInstallation Pool Safety GuidelinesTeflon Taping Instructions Prior to Pressure TestingThreaded Connections Pump PlumbingOperation MaintenanceCaudales de la bomba para piscinas ElectricalDiagnóstico y Resolución de Problemas Troubleshooting Guide MantenimientoContinuación ALMACENAMIENTO/ Acondicionamiento Para EL Invierno FuncionamientoCebado DE LA Bomba Drenaje DE LA BombaInstalación Continuación EléctricaRequisitos DE Succión DE LA Bomba Para Piscina Instrucciones DE Encintado DE TeflónConexiones Antes DE LA Prueba DE PresiónInstalación Replacement Parts ListInformaciones Generales deInformaciones Generales de Seguridad ÍndiceDescripción Medidas de seguridad

APB075PRO, APB100PRO, APB200UPRO, APB150UPRO, APB200PRO specifications

The AquaPRO series includes several advanced models designed for various water treatment needs, catering to both home and commercial applications. The models APB150PRO, APB300PRO, APB100UPRO, APB250UPRO, and APB200PRO share key features and cutting-edge technologies that enhance performance, efficiency, and user convenience.

The AquaPRO APB150PRO is renowned for its robust filtration system, making it an excellent choice for medium-sized households. It incorporates a multi-stage filtration process, including pre-filtration, activated carbon, and reverse osmosis, which effectively removes impurities, chlorine, and harmful contaminants. This model is equipped with a high-efficiency pump that ensures optimal water flow, delivering purified water quickly and efficiently.

The APB300PRO stands out with its higher capacity, suited for larger families or small businesses. It features an enhanced filtration technology that maximizes removal rates and provides a longer lifespan for filter cartridges. This model also includes smart features such as a digital display that monitors filter life, water quality, and operational status, providing users with real-time information and alerts.

Next in line, the AquaPRO APB100UPRO focuses on ultra-pure water production, ideal for laboratories, healthcare facilities, and sensitive industrial applications. This model integrates advanced ultraviolet (UV) sterilization technology, which eliminates bacteria and viruses, ensuring the highest level of water purity. The APB100UPRO also features an automated flushing mechanism that maintains the integrity of the membrane, enhancing its longevity and efficiency.

The APB250UPRO is designed for versatile applications, offering both ultra-pure and regular filtration options. It can easily switch between different filtration modes, making it perfect for users who require both types of water. This flexibility, combined with energy-efficient operation and low maintenance requirements, makes the APB250UPRO a popular choice among users with varying water needs.

Finally, the AquaPRO APB200PRO serves as a balanced option for users looking for performance and value. It incorporates a dual filtration process, combining activated carbon and fine particulate filters, ensuring effective removal of chlorine, sediments, and unpleasant odors. The compact design allows for easy installation and maintenance, making it suitable for both residential and small commercial settings.

In summary, the AquaPRO APB150PRO, APB300PRO, APB100UPRO, APB250UPRO, and APB200PRO models collectively represent a comprehensive range of water treatment solutions with unique features and technologies tailored to meet diverse consumer needs. Whether for home, office, or specialized applications, AquaPRO remains a dependable choice in water purification technology.