AquaPRO APB100UPRO Threaded Connections, Pump Plumbing, Teflon Taping Instructions, Fittings

Page 4

Owner’s Manual

APB075PRO, APB100PRO, APB150PRO, APB200PRO, APB300PRO, APB100UPRO, APB150UPRO, APB200UPRO and APB250UPRO

Installation (Cont.)

The pump mount must be located away from corrosive or flammable chemicals. Do not connect the pump to a municipal water system. The pump is only designed for pool or spa installation. The pump must be installed with at a minimum of 2 main drains equipped with certified anti-entrapment cov- ers that comply with ASME/ANSI A119.19.8 standard (see Figure 2). All air must be re- moved from piping system before operating or testing equipment (see filter manual).

THREADED CONNECTIONS

Use only Teflon® tape or equivalent on threaded plumbing connections. Other pipe compounds may damage threads. Do not use silicone or petroleum based compounds.

PUMP PLUMBING

Suction pipe should be as large as or larger than discharge pipe. Avoid us- ing a suction pipe smaller than pump connection. The pump is designed to accept either 2 or 3 inch suction piping. Larger diameter pipes reduce noise and improve performance.

1.Keep the piping as straight and short as possible, and of suitable size.

2.Avoid connecting an elbow directly into the pump inlet. A length of straight pipe will allow proper entry of the water to the pump.

3.Slope horizontal runs upward to the pump to prevent trapping air.

4.Use independent piping supports to reduce strain on the pump.

5.Keep as much of the suction line as possible below the water level to reduce priming time.

6.Install valves and unions in the pump suction and return lines to facilitate servicing. Valves are also essential for pump maintenance if the system is installed below pool water level.

7.Keep all valves fully open during operation. Partially closed valves waste energy!

Use Teflon tape for making threaded

connections to the pump. Do not use pipe dope.

TEFLON TAPING INSTRUCTIONS

Use only new or clean PVC pipe fittings. Wrap male pipe threads with one to two layers of Teflon tape. Cover entire threaded portion. Do not over tighten. If leaks occur, remove pipe, clean off old tape, rewrap with one to two additional layers of tape and remake the connection.

Internal - 2 in. NPT are available for direct

connection to pipe. The suction line is also designed to accept 3 in. NPT external threaded connection. For best results use the larger diameter suction line.

FITTINGS

Fittings restrict flow; for best efficiency use fewest possible fittings. Avoid fittings which could cause an air trap. Pool fittings must conform to International Associa- tion of Plumbing and Mechanical Officials (IAPMO) standards. Use only non-entrap- ping suction fitting or double suction.

PRIOR TO PRESSURE TESTING

Securely tighten knobs, drain fittings, lid, and system accessories

Air may collect at the highest point in the plumbing system. Normally an air purge valve is provided with the pool filter. Consult pool filter instruction manual for air purging instructions.

Basket lid must be rotated and locked into position as indicated in Figure 3.

Figure 3 - Clamp rings

Test system at a water pressure of 25 psi or less

Water Temperature for test must be less than 100° F

After 24 hours visually check system for leaks.

POOL PUMP SUCTION REQUIREMENTS

Pump suction is hazardous and can trap,

drown or disembowel bathers. Do not use or operate swimming pools or spas if a suction outlet cover is missing, broken, or loose.

Follow the guidelines below for a pump installation which minimizes risk to users of pools and spas.

Ground the motor before connecting

to electrical power supply. Failure to ground the motor may cause severe or fatal electrical shock hazard.

ENTRAPMENT PROTECTION

The pump suction must be designed to eliminate the possibility of suction entrap- ment or hair entrapment/entanglement.

SUCTION COVERS

All suction inlet covers must be maintained and replaced if cracked, broken, or missing. See Figure 2 for outlet cover certification requirements.

TESTING AND CERTIFICATION

All suction inlet covers must comply with ASME/ANSI A112.19.8 specifications for suction fittings for use in swimming pools, spas and whirlpool bathtub applications. The product must be tested for compliance with the standards and the certification must be included with the components.

Single or Multiple Pump Circulation Sys- tems must be provided with a minimum of 2 (two) suction inlets of the approved type.

Do not install multiple pumps in one hydraulic circuit. The pump is not designed to accept output flow from another pump. Do not allow water to back flow through the pump. Water flowing in the discharge and out the suction during an upset condition can cause the motor to rotate backwards. Never attempt to start pump if shaft is rotating due to a hydraulic turbine action, this could cause pump to operate in reverse and damage internal components.

Any pool or spa should immediately

be closed if the cover or grate is damaged or missing.

OUTLETS PER PUMP

Provide at least two hydraulically balanced main drains, with covers for each swimming pool pump suction line. The centers of the main drains suction fitting must be at least three feet apart (see Figure 2). The system must be built so that it cannot operate with the pump drawing water from only one main drain. Two main drains must be con- nected to the pump whenever it is running. If two main drains run into a single suction line, the single suction line can be equipped with a single valve that shuts off both main drains from the pump. A valve in each suction line is not allowed.

Notas

www.aquaprosystems.com

4

21 Sp

Image 4
Contents Manual del usuario Nº DE Modelo Nº DE Serie Fecha DE Instalación24 Sp AquaPRO SystemsContents Safety GuidelinesGeneral Safety Information Lista de RepuestosPool Safety Guidelines InstallationPrior to Pressure Testing Threaded ConnectionsPump Plumbing Teflon Taping InstructionsMaintenance Caudales de la bomba para piscinasElectrical OperationDiagnóstico y Resolución de Problemas Mantenimiento Troubleshooting GuideContinuación Funcionamiento Cebado DE LA BombaDrenaje DE LA Bomba ALMACENAMIENTO/ Acondicionamiento Para EL InviernoEléctrica Instalación ContinuaciónInstrucciones DE Encintado DE Teflón ConexionesAntes DE LA Prueba DE Presión Requisitos DE Succión DE LA Bomba Para PiscinaReplacement Parts List InformacionesGenerales de InstalaciónÍndice DescripciónMedidas de seguridad Informaciones Generales de Seguridad

APB075PRO, APB100PRO, APB200UPRO, APB150UPRO, APB200PRO specifications

The AquaPRO series includes several advanced models designed for various water treatment needs, catering to both home and commercial applications. The models APB150PRO, APB300PRO, APB100UPRO, APB250UPRO, and APB200PRO share key features and cutting-edge technologies that enhance performance, efficiency, and user convenience.

The AquaPRO APB150PRO is renowned for its robust filtration system, making it an excellent choice for medium-sized households. It incorporates a multi-stage filtration process, including pre-filtration, activated carbon, and reverse osmosis, which effectively removes impurities, chlorine, and harmful contaminants. This model is equipped with a high-efficiency pump that ensures optimal water flow, delivering purified water quickly and efficiently.

The APB300PRO stands out with its higher capacity, suited for larger families or small businesses. It features an enhanced filtration technology that maximizes removal rates and provides a longer lifespan for filter cartridges. This model also includes smart features such as a digital display that monitors filter life, water quality, and operational status, providing users with real-time information and alerts.

Next in line, the AquaPRO APB100UPRO focuses on ultra-pure water production, ideal for laboratories, healthcare facilities, and sensitive industrial applications. This model integrates advanced ultraviolet (UV) sterilization technology, which eliminates bacteria and viruses, ensuring the highest level of water purity. The APB100UPRO also features an automated flushing mechanism that maintains the integrity of the membrane, enhancing its longevity and efficiency.

The APB250UPRO is designed for versatile applications, offering both ultra-pure and regular filtration options. It can easily switch between different filtration modes, making it perfect for users who require both types of water. This flexibility, combined with energy-efficient operation and low maintenance requirements, makes the APB250UPRO a popular choice among users with varying water needs.

Finally, the AquaPRO APB200PRO serves as a balanced option for users looking for performance and value. It incorporates a dual filtration process, combining activated carbon and fine particulate filters, ensuring effective removal of chlorine, sediments, and unpleasant odors. The compact design allows for easy installation and maintenance, making it suitable for both residential and small commercial settings.

In summary, the AquaPRO APB150PRO, APB300PRO, APB100UPRO, APB250UPRO, and APB200PRO models collectively represent a comprehensive range of water treatment solutions with unique features and technologies tailored to meet diverse consumer needs. Whether for home, office, or specialized applications, AquaPRO remains a dependable choice in water purification technology.