6 INSPECTION, MAINTENANCE AND TROUBLESHOOTING
6.2Maintenance for 6302GADH Adjustable Height Rub Panels and Glide Pads
The application of white lithium grease to the glide pads must be done every six months to keep the tub in good working order.
1.Remove the side panel to access the rub panels and glide pads.
2.Generously apply white lithium grease to the stainless steel rub panels and glide pads.
3.Repeat STEPS
4.Replace the side panels.
6.3Troubleshooting
If problems are not remedied, contact technical support at
SYMPTOMS | FAULTS |
| SOLUTION |
|
Hydromassage System |
|
|
|
|
|
|
|
|
|
System will not start | No electrical power to tub |
| Check and reset breaker |
|
|
|
|
|
|
| Switch air hose disconnected |
| Reconnect hose to switch and controller |
|
|
|
|
|
|
System is ineffective | Water deposits in whirlpool jets |
| Disassemble, inspect and clean whirlpool jets |
|
|
|
|
| |
System is noisy | Whirlpool jets are turned on without water |
| Turn off the whirlpool jets. Add water to the tub to completely cover the | |
| completely covering the jet assemblies |
| jet assemblies and test the whirlpool function again. |
|
|
|
|
|
|
Tub Operation |
|
|
|
|
|
|
|
|
|
No water flow | Water supply turned off/no electrical con- |
| Turn on water supply/check and reset breaker |
|
| nection |
|
|
|
|
|
|
| |
Restricted water flow | Water temperature control valve |
| Inspect and clean the water temperature control valve. Refer to the Moen | |
|
|
| service manual at www.moen.com. Search for Model 3371 ExactTemp | |
|
|
| Temperature Control Valve, Service Manual Number 153768. | |
|
|
|
|
|
Invacare® TheraPure™Supine Whirlpool Tubs | 30 | Part No. 1167456 |