Maintenance For The Squeegee

MAINTENANCE

2.Check and clean the filter screen in the solution hose. To clean the screen, follow this procedure: (See figures 11 and 12 page 18)

a.Turn the connector to the left.

b.Remove and clean the filter screen.

c.Install the filter screen in the hose. Turn the connector to the right to connect the hose.

3.Use a grease gun to lubricate the caster. See figure 6.

4.Check the squeegee and the scrub brush or the pad driver for damage.

5.Check the squeegee and the vacuum hose for damage, leaks and obstructions.

Maintenance For The Squeegee

To remove the squeegee, follow this procedure:

1.Remove the squeegee assembly by loosening the two knobs that attach the squeegee to the machine. Pull the squeegee assembly off. See figure 7.

2.Inspect the squeegee blade.

3.If the blade is worn, turn the blade so that a new edge is in the wiping position.

4.Reinstall squeegee assembly on the machine.

How To Adjust The Squeegee

The following adjustments are set at the factory, however they may require slight adjustment.

Adjusting Squeegee Pressure:

To adjust the pressure, refer to Figure 8. Proper adjustment will produce a uniform flare along the rear blade when the machine is moved forward. To increase pressure, loosen bolt and slide squeegee mount down. To decrease the pressure, loosen the bolt and slide squeegee mount up.

Figure 6

Figure 7 Figure 7

Figure88

CLARKE TECHNOLOGY Operator's Manual -Encore S20E

Page -19-

Image 19
Contents ENCORE S20E READ THIS BOOKOperators Manual Table of Contents ADVERTENCIA AVERTISSEMENTOPERATOR SAFETY INSTRUCTIONS WARNING: Maintenance and repairs performed by unauthorized personnel could result in damage or injury. Maintenance and repairs must be performed by authorized Clarke Technology personnel only Introduction & Machine Specifications Introduction & Machine SpecificationsSPECIFICATIONS Procedures For Transporting How to Remove the Machine From a Van or Truck Procedures For Transpoting contMachine Control Panel DD E A BC FG FigureFigure Machine Controls and FeaturesFigure Figure 4a Figure 4b Figure 5a Figure 5b Figure 5c How To Prepare the Machine For OperationHow To Install The Brush Or Pad Driver How To Remove The Brush or Pad DriverHow To Operate The Machine Figure How To Clean A FloorHow To Clean A Very Dirty Floor Operating The MachineSection Parts and Service ManualENCORE S20EACTION HOW TO CORRECT PROBLEMS IN THE MACHINEPROBLEM CAUSECAUSE PROBLEMACTION MAINTENANCE MAINTENANCE Figure Figure Figure Figure Do These Procedures When You End Your WorkFigure Figure 7 Figure Figure88 Maintenance For The SqueegeeHow To Adjust The Squeegee Adjusting Squeegee PressureFigure How To Adjust The Squeegee contFigure Figure 230 Volt AccessoriesAccessories 115 VoltSERVICE FACILITIES U. S. A. LocationsEuropean Locations Customer Service - Technical Service -CLARKE TECHNOLOGY CLARKE TECHNOLOGY U.S. WARRANTYEIGHT YEAR U.S. GUARANTEE CLARKE TECHNOLOGY POLYDUR TANK