Craftsman MGP-679580, 919.679580 owner manual To Start Your Generator, General Recommendations

Page 12

Low Oil Shutdown

Your Craftsman generator engine is equipped with Low Oil Shutdown. Low Oil Shutdown is a safety device designed to protect your engine from damage in the event the oil level in the crankcase is low.

If while the engine is running, the oil gets low, it will automatically shut itself down and will not restart until the oil is added. If the oil is low before start-up, the genera- tor will not start until oil is added.

NOTE: The Low Oil Shutdown mechanism is very sensi- tive. You must fill the engine to the full mark on the dipstick to inactivate this safety device.

Gasoline

Your generator engine is 4 cycle. Use unleaded fuel only. Never mix oil with gasoline.

CAUTION: Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine.

WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.

Use clean, fresh, regular unleaded gasoline with a mini- mum of 85 octane. Do not mix oil with gasoline. If unleaded fuel is not available, leaded fuel may be used.

To Start Your Generator

Make sure fuel shutoff valve is turned to the open position.

CLOSE

OPEN

Remove gas cap.

Add unleaded gasoline, slowly to fuel tank.

Do not overfill.

On the engine there is a choke/run lever. Place this lever to the choke position.

Crank engine.

Electric Starting: Press starter switch to the start position. When the engine is started the switch will remain in the run position until the switch is turned off.

OFF RUN START

Manual Starting: Grasp rope handle and pull slowly until resistance is felt. Then pull cord rapidly to overcome com- pression, prevent kickback and start engine.

When engine starts, gradually move choke lever to “Full Run Position.”

If the engine fails to start after (3) pulls, move the choke position and pull starter rope again.

For hot engine starts make sure choke lever is in the “Full Run Position.”

Connecting Electrical Loads

Let engine run and warm up for about five minutes after starting.

Plug in the desired 120 or 240 volts tools.

DO NOT connect 240 volt equipment to the 120 volt duplex receptacles.

DO NOT connect 3-phase loads to the panel receptacles.

IMPORTANT: You should always add up the rated watts of all lights, tools and appliances you are power- ing at one time. This total should not exceed the rated capacity of you generator or circuit breaker rating of the receptacle supplying power.

Stopping The Engine

Disconnect all electrical loads.

Switch the start/off switch to the off position.

OFF RUN START

IMPORTANT: Never store engine with fuel in tank, indoors, or in enclosed, poorly ventilated areas or where fuel fumes may reach an open flame.

GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to maintain your generator.

12 — ENG

Image 12
Contents Owners Manual Sold by Sears Canada, Inc., Toronto, Ont. M5B2B8Table of Contents Safety Guidelines Definitions Risk of Electrocution and FireRisk of Electrocution and Fire cont’d Risk of Fire ANY Confined AreaRisk of Breathing Inhalation Hazard Risk of Unsafe Operation Risk of HOT SurfacesRisk of Moving Parts Assembly Carton ContentsRisk from Lifting Remove Generator from CartonOperation Know Your GeneratorBattery Installation Full Power SwitchReceptacles Generator CapacityConnecting Generator To Main Electrical Supply Obtaining Electricity from GeneratorBefore Starting Engine Extension CordTo Start Your Generator General RecommendationsMaintenance Generator MaintenanceEngine Maintenance Service Air CleanerService Adjustments Clean and Replace Spark PlugClean Guard/Muffler CarburetorStorage Instructions Engine PreparationGenerator ENG ENG PartsDirect Génératrice DE Vendu par Sears Canada, Inc., Toronto, Ont. M5B 2B8Table DES Matières EntretienMesures DE Sécurité Définitions Conserver CES DirectivesAvertissement Risques D’ÉLECTROCUTION ET D’INCENDIE Suite Risques D’INCENDIE Rieur OU Dans UN Endroit ClosRisques AUX Voies Respiratoires ET Risques D’INHALATION Risques D’UNE Utilisation Dangereuse Risques Reliés AUX Surfaces ChaudesRisques Reliés AUX Pièces Mobiles Risques Lors DU Levage AssemblageContenu DE L’EMBALLAGE Retrait DE LA Génératrice DE SON EmballageFonctionnement Bien Connaître Votre GénératriceInstallation de la batterie Prises DE CourantInterrupteur DE Pleine Puissance Capacité DE LA GénératriceAvant DE Démarrer LE Moteur RallongesRemplissage d’huile moteur Recommandations Générales Démarrage de la génératriceEntretien Entretien DE LA GénératriceEntretien DU Moteur Entretien du filtre à airRéglages D’ENTRETIEN Nettoyage du protecteur/silencieuxCarburateur RégulateurEntreposage Directives Pour L’ENTREPOSAGEPréparation du moteur GénératriceResponsabilités de garantie du propriétaire Entretien inadéquat Entretien ET Pieces DE Rechange

MGP-679580, 919.679580 specifications

The Craftsman 919.679580, also known as the MGP-679580, is a high-quality portable air compressor designed to meet the needs of both DIY enthusiasts and professional tradespeople. This versatile tool is particularly well-regarded for its powerful performance, user-friendly features, and durable construction, making it a popular choice for a variety of applications.

One of the standout features of the Craftsman 919.679580 is its efficient motor, which provides ample power to deliver a maximum pressure of up to 150 PSI. This high-pressure capability ensures that the compressor can handle a wide range of tasks, from inflating tires to powering pneumatic tools. With a generous 6-gallon tank, the unit maintains a continuous supply of air, allowing for extended use without frequent interruptions for recharging.

The dual piston pump system is designed to enhance the compressor's performance, ensuring quicker recovery times and increased airflow. This technology enables the 919.679580 to operate efficiently, producing a consistent output that meets the demands of more intensive tasks. Additionally, the oil-free design of the pump not only minimizes maintenance but also promotes a cleaner working environment, as there is no risk of oil spills or mess.

User convenience is another hallmark of the MGP-679580. The unit comes equipped with an ergonomic handle and lightweight construction, allowing for easy portability. Integrated cord storage and hose management features also help keep workspaces organized, reducing clutter and enhancing safety.

The Craftsman 919.679580 prioritizes safety and user-friendliness by incorporating features such as a durable, protective housing that guards against damage during transportation. The pressure gauge and regulator are easily accessible, allowing users to monitor and adjust pressure levels as needed.

In conclusion, the Craftsman 919.679580, MGP-679580, distinguishes itself in the market with a blend of powerful performance, innovative technology, and practical features. Its durable construction and ease of use make it an excellent investment for anyone in need of a reliable air compressor. Whether for home improvement projects, automotive tasks, or professional applications, this compressor is built to deliver the performance and reliability that users demand. Its balanced design ensures that it can tackle the toughest jobs while remaining accessible for everyday use, solidifying its reputation as a must-have tool in any toolkit.