APC SMT1500 Display Interface, Overview, Using the display interface, Standard menus

Page 8

Display Interface

Overview

Online indicator

UPS Output On/Off button On Battery indicator

Fault indicator

Replace Battery indicator Display screen

UP/DOWN buttons ENTER button ESCAPE button

Using the display interface

APC by Schneider Electric

su0343a

Use UP and DOWN to scroll through the main menu options. Press ENTER to view the sub-menus under each main menu option. Press ESCAPE to exit a sub-menu and return to a main menu.

Standard menus

The Standard menus are the most commonly used menus for the UPS.

Menu

General Functions

 

 

Status

View basic information about the UPS:

 

• Operating mode

 

• Switched Outlet status, On or Off

 

• Efficiency of the UPS

 

• Information about the load

 

• Battery capacity

 

• Estimated runtime

 

• Input and output voltage and frequency

 

• Information about the last transfer to battery power

 

Self-test results

Configuration Configure the settings for the UPS:

Language

Local power quality: Good, Fair, Poor

Choose Standard or Advanced menus

LCD Display mode, Always On or Power-Saving

Audible alarms

Reset to Factory Defaults

Test & Diags Use the Test & Diags menu to have the UPS perform a self-test.

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower

5

Image 8
Contents Smart-UPSUPS Contents Smart-UPS Factory Warranty Safety OverviewProduct Description Product Overview1000/1500 VA 230 Vac Rear panels1000/1500 VA 120 Vac 750 VA 120 Vac Specifications InstallationEnvironmental Specifications Operating ConditionsConnect Equipment to the UPS Rear Panel FeaturesOperation Using the display interface Display InterfaceOverview Standard menusAdvanced menus Configuration UPS SettingsStart-up Settings General SettingsLow Battery Battery Replacement Audible AlarmBattery Self SettingMain Outlet Group and the Switched Outlet Group Using the Main Outlet Group and the Switched Outlet GroupNetwork Management Card Settings Emergency Power Off EPO OverviewNormally open contacts Normally closed contactsTroubleshooting UPS does not provide expected backup timeDisplay interface indicators flash sequentially UPS is emitting an audible beeping soundDisplay interface has a Site Wiring Fault message Problem and Possible CauseReplace battery indicator is illuminated Service and Support ServiceTransport the unit APC Worldwide Customer SupportSmart-UPS Factory Warranty Limited WarrantyHarmonized Standards Applicable CouncilDirectives Type of Equipment Model Numbers990-3534-001 06/2009