Briggs & Stratton 030209-2 manual Air Cooling System, Check Valve Clearance, Carburetor Adjustment

Page 18

Air Cooling System

Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly. For this reason, we recommend you have an authorized Briggs & Stratton service dealer clean the cooling system (A) per recommended intervals (see Maintenance Schedule in beginning of Maintenance section). Equally important is to keep top of engine free from debris. See Clean Debris.

A

Check Valve Clearance

Regular valve clearance check and adjustment will improve performance and extend engine life. This procedure cannot be done without partial engine disassembly and the use of special tools. For this reason we recommend that you have an authorized service dealer check and adjust valve clearance at recommended intervals (see Maintenance Schedule in the Maintenance section).

Carburetor Adjustment

The carburetor on this engine is low emission. It is equipped with a non-adjustable idle mixture valve. Top speed has been set at the factory. If adjustment is required, see an authorized Briggs & Stratton service dealer.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

18

BRIGGSandSTRATTON.COM

Image 18
Contents Operator’s Manual Engine Where to Find UsGenerator Date PurchasedTable of Contents Safety alert symbol is used with a signal word Operator SafetySafety Rules Hazard Symbols and MeaningsEngine exhaust from this product contains Certain components in this product and relatedBroken bones, fractures, bruises, or sprains could result When Testing for Engine Spark Contact with muffler area can result in serious burnsUnintentional sparking can result in fire or electric shock Install Wheel Kit AssemblyShipment Contents Unpack GeneratorFuel must meet these requirements Add Engine OilAdd Fuel High AltitudeGenerator Location Connecting to a Building’s Electrical SystemSystem Ground Special RequirementsVolt AC, 20 Amp, Duplex Receptacles May be Features and ControlsUsed to supply electrical power for the operation Items Not Shown120/240 Volt AC, 30 Amp, Locking Receptacle Cord Sets and ReceptaclesNema L14-30 Volt AC, 20 Amp, Duplex ReceptaclesOperation Starting the EngineConnecting Electrical Loads Stopping the EngineMove fuel valve to Off position Don’t Overload Generator Wattage Reference GuideMaintenance Maintenance ScheduleGenerator Maintenance Engine Maintenance OilInstall spark plug and tighten firmly Service Air CleanerService Spark Plug Service Spark ArresterCarburetor Adjustment Air Cooling SystemCheck Valve Clearance Storage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty AC Load Current Product SpecificationsCommon Service Parts 800Manual del Operario Motor Dónde encontrarnosGenerador Fecha de compraMontaje Resolución de problemas GarantíasSeguridad de operario Controles y característicasReglas de seguridad Seguridad de operarioDescripción del equipo Símbolos de peligro y sus significadosDeterminados componentes en este producto y los Declaradas cancerígenas, causantes deCuando Ajuste O Haga Reparaciones a SU Máquina Generador Cuando Pruebe LA Bujía DEL MotorContenido de la caja MontajeDesembalaje del generador Instale el juego de ruedasEvite el daño del generador Agregar aceite al motorVuelva a colocar el tapón y apriételo firmemente Gran altitudUbicación del generador Tierra del sistemaConexión al sistema eléctrico de un edificio Requisitos especialesControles y características Amperios, monofásica de 60 HzCulatazo el Principio Usó para comenzar motor Tomas eléctricas dobles de 120 V CA y 20 a Juegos de cordones y enchufes conectores120/240 Voltios AC, 30 Amperios, Receptáculo de Seguridad Amps o mayoresOperando Encienda el motorEl motor podría petardear, incendiarse o dañarse Conexión de cargas eléctricasParada del motor Gire la válvula de combustible blanca hasta la posición OffEjemplo No sobrecargar el generadorCapacidad Control de la energíaMantenimiento Plan de mantenimientoMantenimiento del Generador Comprobación del Nivel de Aceite Mantenimiento del MotorAceite Recomendaciones sobre el aceite Adición de Aceite del MotorServicio del bujía Servicio del depurador de aireLimpia E Limpie la Pantalla ApagachispasSistema de refrigeración de aire Comprobación de holgura de la válvulaAjuste del Carburador Almacenamiento Resolución de problemas Problemo Causa AccionResponsabilidades de la garantía del propietario GarantíasGarantía del sistema de control de emisiones Operaciones de mantenimiento que se enumeran en lasInformación sobre emisiones Garantía Limitada Especificaciones del producto Servicio común despideCorriente Carga de C.A