Assembly

Read entire operator’s manual before you attempt to assemble or operate your new generator.

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil.

If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115. If calling for assistance, please have the model, revision, and serial number from the data tag available. See Generator Controls and Features for identification label location.

Unpack Generator

1.Set the carton on a rigid, flat surface.

2.Remove everything from carton except generator.

3.Open carton completely by cutting each corner from top to bottom.

4.Leave generator on carton to install wheel kit.

Shipment Contents

The generator is supplied with:

Engine oil bottle

Operator’s manual

Wheel kit

Install Wheel Kit

The wheel kit is designed to greatly improve the portability of your generator.

NOTE: Wheel kit is not intended for over-the-road use. You will need the following tools to install this wheel kit:

13mm socket wrench

13mm open end wrench

Pliers

Safety glasses

Install the wheel kit as follows:

1.Tip generator so that engine end is up.

2.Slide axle (A) through both mounting brackets.

3.Slide a wheel (B) over the axle.

4.Place a washer (C) on axle and then place an e-ring (D) in axle groove.

CAUTION

E-rings can cause eye injury.

E-rings can spring back and become airborne when installing or removing.

Always wear eye protection when installing/removing e-rings.

5.Install e-ring with pliers, squeezing from top of e-ring to bottom of axle.

6.Repeat step 3 thru 5 to secure second wheel.

7.Tip generator so that engine side is down.

8.Attach support leg (E) using two 13mm wrenches with 25mm cap screws (F) and lock nuts (G).

9.Center lifting handle (H) on cradle. Attach handle using two 13mm wrenches with 45mm capscrews (J) and hex nuts (K).

10.Return generator to normal operating position (resting on wheels and support leg).

11.Check each fastener to ensure it is secure.

 

Typical Generator Shown

J

 

K

 

H

B

 

 

C

 

A

E

 

F

D

G

 

 

7

Image 7
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Hazard Symbols and Meanings Operator SafetySafety Rules Safety alert symbol is used with a signal wordCertain components in this product and related Engine exhaust from this product containsBroken bones, fractures, bruises, or sprains could result Contact with muffler area can result in serious burns When Testing for Engine SparkUnintentional sparking can result in fire or electric shock Unpack Generator AssemblyShipment Contents Install Wheel KitHigh Altitude Add Engine OilAdd Fuel Fuel must meet these requirementsSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator LocationItems Not Shown Features and ControlsUsed to supply electrical power for the operation Volt AC, 20 Amp, Duplex Receptacles May beVolt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-30 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationStopping the Engine Connecting Electrical LoadsMove fuel valve to Off position Wattage Reference Guide Don’t Overload GeneratorMaintenance Schedule MaintenanceGenerator Maintenance Oil Engine MaintenanceService Spark Arrester Service Air CleanerService Spark Plug Install spark plug and tighten firmlyAir Cooling System Carburetor AdjustmentCheck Valve Clearance Storage Troubleshooting Owner’s Warranty Responsibilities Emissions Control System WarrantyWarranties Emission Information MaintenanceClaims and Coverage Exclusions Limited Warranty 800 Product SpecificationsCommon Service Parts AC Load CurrentManual del Operario Fecha de compra Dónde encontrarnosGenerador MotorControles y características Resolución de problemas GarantíasSeguridad de operario MontajeSímbolos de peligro y sus significados Seguridad de operarioDescripción del equipo Reglas de seguridadDeclaradas cancerígenas, causantes de Determinados componentes en este producto y losCuando Pruebe LA Bujía DEL Motor Cuando Ajuste O Haga Reparaciones a SU Máquina GeneradorInstale el juego de ruedas MontajeDesembalaje del generador Contenido de la cajaGran altitud Agregar aceite al motorVuelva a colocar el tapón y apriételo firmemente Evite el daño del generadorRequisitos especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorAmperios, monofásica de 60 Hz Controles y característicasCulatazo el Principio Usó para comenzar motor Amps o mayores Juegos de cordones y enchufes conectores120/240 Voltios AC, 30 Amperios, Receptáculo de Seguridad Tomas eléctricas dobles de 120 V CA y 20 aEncienda el motor OperandoGire la válvula de combustible blanca hasta la posición Off Conexión de cargas eléctricasParada del motor El motor podría petardear, incendiarse o dañarseControl de la energía No sobrecargar el generadorCapacidad EjemploPlan de mantenimiento MantenimientoMantenimiento del Generador Adición de Aceite del Motor Mantenimiento del MotorAceite Recomendaciones sobre el aceite Comprobación del Nivel de AceiteLimpie la Pantalla Apagachispas Servicio del depurador de aireLimpia E Servicio del bujíaComprobación de holgura de la válvula Sistema de refrigeración de aireAjuste del Carburador Almacenamiento Problemo Causa Accion Resolución de problemasOperaciones de mantenimiento que se enumeran en las GarantíasGarantía del sistema de control de emisiones Responsabilidades de la garantía del propietarioInformación sobre emisiones Garantía Limitada Servicio común despide Especificaciones del productoCorriente Carga de C.A