Campbell Hausfeld warranty Maintenance, GN0950 and GN0800, Extension Cords

Page 3

GN0950 and GN0800

Operation (Continued)

4.

Move the choke/run

 

switch to the choke

 

position.

5.

Turn engine switch

 

on by pressing the

 

top of the switch.

EXTENSION CORDS

MAXIMUM RECOMMENDED LENGTHS (IN FEET)

Amps

Watts

Watts

#8

#10

#12

#14

#16

 

120 V

220 V

Wire

Wire

Wire

Wire

Wire

 

 

 

 

 

 

 

 

2.5

300

600

 

1000

600

375

250

5

600

1200

 

500

300

200

125

7.5

900

1800

 

350

200

125

100

6.

Pull the starter rope

 

with a brisk smooth

 

motion.

7.

Return choke/run switch to the run

 

position.

8.

After each start up, allow engine to

 

run 2-3 minutes with no load.

Engine speed is

! CAUTION preset to provide proper output voltage. Never attempt to modify or adjust engine speed or output voltage.

ENGINE BREAK-IN

The first 25 hours of operation is considered the break-in period for the engine. During this time, use a 30:1 mix of gas and oil and operate at less than 75% of the load limit.

GENERATOR SHUT OFF

1.Remove all electrical load devices from the generator.

2.Allow the engine to run for 2-3 minutes with no electrical loads.

3.Turn engine switch off by pressing the bottom of the switch. This will stall the engine.

4. Set the fuel switch to the closed (horizontal) position.

5.Verify that the generator has completely stopped.

6.Allow unit to cool before placing in storage.

LOAD DEVICES

1.The 120 volt receptacles (type NEMA 5-15) are rated for 13 amps on 60 Hz models (GN950). The 220 volt receptacles are rated for 10 amps on 50 Hz models (GN800).

2.Total combined load through any combination of receptacles must not exceed rated load limits of generator.

3.Reduce load if

AC Protector (circuit breaker) turns off. Press

button to reset.

NOTE: Power draw can be calculated by multiplying volts and amps. The resulting number is wattage.

Never exceed the posted maximum wattage for the generator or any individual receptacle. Refer to owner's

manuals and product tags to determine the wattage of electrical load devices.

Long power cords and extension cords draw additional power. Keep cords at minimum possible length. See chart above.

Maintenance

INFREQUENT USAGE

If the generator is used infrequently, starting difficulty may occur. To help prevent difficulty starting, the generator should be run for approximately 30 minutes per week.

STORAGE

If the generator is not to be used for extended periods of time, the following pre-storage procedures should be performed:

1.Drain all fuel from the tank, lines, and carburetor.

2.Remove spark plug. Clean off any carbon deposits. Check for discoloration – plug should be tan in color. Check the gap; it should be 0.7 – 0.8mm.

ESTIMATED POWER USAGE (WATTS)

Load Device

Watts

Load Device

Watts

 

 

 

 

Computer

300

Hand Vacuum

500

CD Player

100

Power Drill

500

VCR

100

Hedge Trimmer

500

Radio

100

Weed Whip

500

Television

300

Coffee Maker

1200

Receiver

420

Slow Cooker/Frying Pan

200

Microwave

800

Outdoor Lights

75-150

Blender

300

Bug Light

50

3.Pour approximately one teaspoon of oil into spark plug hole.

4.Pull starter cord several times to spread the oil throughout the cylinder.

5.Slowly pull the starter cord until resistance is felt. This indicates that the piston is moving upward on the

3

Image 3
Contents Unpacking General SafetyPortable Generators DescriptionStarting OperationPRE-OPERATION GroundingMaintenance GN0950 and GN0800Extension Cords Fuel Filter Maintenance ScheduleSpark Plug Air FilterSymptom Possible Causes Corrective Action GN0950 and GN0800 Troubleshooting ChartLimited Warranty Segurança Geral Geradores PortáteisDescrição DesembalagemAterramento OperaçãoContinuação PRÉ-OPERAÇÃOManutenção Ou a cada 3 meses Programa DE ManuteçãoAção Cada 150 horas11 Pg GN0950 and GN0800 Tabela para Pesquisa de Avarias12 Pg Quem Concede Esta Garantia Garantidor13 PG NotasMedidas de Seguridad Generadores portátilesDescripcíon Para DesempacarConexion CON Tierra FuncionamientoContinuación Antes DE Manejar EL GeneradorCordones DE Extension MantenimientoArtículo Acción Cada 50 horas Cada 150 horas Cada mes Planificación DE Mantenimiento18 Sp Guía de Diagnóstico de AveríasGarantía Limitada 19 SpNotas

GN0800, GN0950 specifications

The Campbell Hausfeld GN0800 and GN0950 are powerful and efficient air compressors designed to cater to the needs of both DIY enthusiasts and professional users alike. Known for their durability and performance, these models are equipped with features that make them stand out in a crowded market.

The GN0800 is a 1.0 HP, 8-gallon air compressor, providing ample airflow for a variety of tasks such as inflating tires, powering pneumatic tools, and spraying paint. Its oil-free pump offers a maintenance-free experience, meaning users can focus on their projects without the hassle of oil changes. The GN0800 also features a quick recovery time; with a maximum pressure of 125 PSI, it can quickly recharge, allowing for continuous use in demanding applications.

On the other hand, the GN0950 comes with a more robust configuration. This model is designed to tackle tougher jobs and heavy-duty applications. It boasts a 2.0 HP motor and a large 9-gallon tank, enabling it to store more air, which lends to longer run times without frequent cycling. The GN0950 can reach up to 145 PSI, providing even higher pressure for more demanding tasks, making it suitable for a wide range of industrial and construction applications.

Both models feature a compact design and lightweight construction, making them easily portable. They come equipped with conveniently placed handles and wheels, which enhance mobility around job sites or workshops. Additionally, these compressors feature multiple outlet ports, allowing users to connect various tools simultaneously, improving productivity and efficiency.

In terms of safety, the Campbell Hausfeld GN series is designed with user protection in mind. They include thermal overload protection, which prevents the motor from overheating, extending the life of the compressor.

Another important aspect is their noise level. Both the GN0800 and GN0950 are designed to operate quietly, allowing users to work comfortably without excessive noise disrupting their tasks.

In summary, the Campbell Hausfeld GN0800 and GN0950 are reliable air compressors that offer excellent performance, durability, and features that cater to versatile applications, making them an excellent investment for anyone looking to undertake air-powered tasks effectively.