Check the status of projector
Check the status of projector
In the “Power & Status” page, you can control the projector power, and also you can check the status of the projector as follows. To change the page, click on the page number linked text.
Items | Description |
|
|
|
|
|
|
Lamp Mode | Displays 2 lamps or 4 lamps mode and lamp status as below icons with | ||||||
|
| Lamp1/Lamp2/Lamp3/Lamp4 order. |
|
| |||
|
|
|
|
|
|
|
|
|
|
| Yellow |
|
| Red |
|
|
|
| ................Normal |
|
| ................Lamp replacement required |
|
|
|
| Gray |
|
| Gray with X |
|
|
|
| ................Off |
|
| ................Abnormality of the lamp |
|
Accumulated |
|
|
|
|
|
| |
|
|
|
|
|
| ||
Displays the accumulated lamp use time in hour units (h) and displays each | |||||||
|
| time with Lamp1/Lamp2/Lamp3/Lamp4 order. | |||||
Accumulated |
|
|
|
|
|
| |
Displays the accumulated projector use time in hour unit (h). | |||||||
Power Status | Displays the status of the lamp. |
|
| ||||
Projector Condition | Displays the status of the projector's power. | ||||||
Input Status | Displays the selected slot. |
|
| ||||
Selection | .......................... | Displays the selected input mode. |
|
| |||
Signal Status | Displays the signal status of the selected input mode. | ||||||
Internal temperature | Displays the temperature at internal thermal sensors in degrees. The icons |
[A]and [B] on the page represent the thermal sensors located in the projec- tor. If the temperature at one of those sensors exceeds specified tempera- ture, the appearance of its icon changes to the following alert icon to let users know about the abnormal temperature. Please check surrounding tem- perature of the projector, check for clogged air filters and check area sur- rounding the ventilation fans.
The icons [A] and [B] represent the sensors located in the projector as follows: [A]: Surrounding temperature of the projector *
[B]: Internal temperature of the projector
*The indicated peripheral temperature of the projector is a little higher than actual surrounding temperature.
Network Board
OWNER’S MANUAL
ENGLISH
37