Intel ERP2U manual Mechanical Overview, Required Optional

Page 7

SSI

ERP2U Power Supply Design Guide, V1.0

4Mechanical Overview

STATUS

Required (Optional)

Note: Some features are noted as optional in the enclosure drawing figure below. These features may be use in some chassis designs where only top access is allowed for the cage mounting.

The ERP2U is a power sub-system made up of a cage and redundant, hot swappable power supply modules. A mechanical drawing of the cage is shown below in Figure 1. This cage is intended to be mounted in the system and not redundant or hot swappable. The exterior face of the cage accepts hot swappable power supply modules. The cage distributes output power from the modules to a wire harness. Cooling fans may be located in the modules or cage. If the cooling fans are located in the cage, they may optionally be redundant. If the cage has redundant cooling the cage depth may be extended to allow for the additional series fan. A recommended power supply module solution is the SSI TPS power supply. Refer to www.ssiforum.org for the latest TPS Design Guide. The cage may have IEC inlet connector(s) and EMI filtering to distribute AC power to the power supply modules or the AC may plug directly into the modules. Three different configurations of the power sub-system are also shown below in Figure 1.

Optional mounting features for top access mounting of the power supply.

Allow for 1.2mm

Power Module

Configuration Options

protrusion (x4)

 

AC

AC

Module Module

AC

AC

Module

Module

AC

 

 

Module

AC

 

 

Module

SSI TPS Power Supply Configuration No Fans in modules

AC inlets and EMI filter in cage Optional Dual AC Inlets

Optional 3.3V, 5V DC/DC converters in cage

Vertical Power Supply Configuration Fans in modules

AC inlets on modules Dual AC Inlets

Optional 3.3V, 5V DC/DC converters in cage

Horizontal Power Supply Configuration Fans in modules

AC inlets on modules Dual AC Inlets

Optional 3.3V, 5V DC/DC converters in cage

Figure 1: Enclosure Drawing

- 7 -

Image 7
Contents SSI Disclaimer Contents Agency Requirements TablesConceptual Overview PurposeRequired Definitions/Terms/AcronymsRequired Optional Mechanical OverviewRecommended Optional Chassis Mounting FeaturesAirflow Requirements OptionalRedundant AC Inlets Temperature RequirementsAC Inlet Connector AC Input RequirementsAC Input Rating AC Input Voltage SpecificationOutput Minimum Power Efficiency EfficiencyAC Line Fuse AC Line DropoutAC Inrush AC Line Surge Transient Performance AC Line Transient SpecificationAC Line Fast Transient Specification AC Line Sag Transient PerformanceOptional Processor Power Connector DC Output SpecificationOutput Connectors Required Baseboard power connectorP9 Floppy Power Connector Required Peripheral Power ConnectorsRequired Floppy Power Connector Peripheral Power ConnectorsRemote Sense Optional Server Signal ConnectorServer Signal Connector Grounding480 W Load Ratings Output Power/Currents350 W Load Ratings Voltage Minimum Continuous Maximum Continuous PeakStandby Outputs Voltage RegulationVoltage Regulation Limits Transient Load Requirements Dynamic LoadingCapacitive Loading Ripple / Noise+3.3 +12 +5 VSB RedundancyHot Swap Requirements Ripple and NoiseSSI Output Voltage Timing Timing RequirementsDescription Recommended Description Turn On/Off TimingTurn On/Off Timing Over Current Protection Protection CircuitsCurrent Limit 240VA ProtectionOutput Voltage Over Temperature ProtectionOver Voltage Protection Over Voltage LimitsPSON# Control and Indicator FunctionsPson # Signal Characteristic Signal Type Pwok delayPwok Signal Characteristics Pwok Power OKProduct Info Area Field Replacement Unit FRU SignalsSMBus Communication Module FRU Data Module FRU Data FormatField Name PS Info Field Information Definition MultiRecord AreaLED Indicators LED IndicatorsPower Supply LEDs 10Agency Requirements Mtbf