SSI

ERP2U Power Supply Design Guide, V1.0

Disclaimer:

THIS SPECIFICATION IS PROVIDED "AS IS" WITH NO WARRANTIES

WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR

SAMPLE. WITHOUT LIMITATION, THE PROMOTERS (Intel Corporation, NEC Corporation, Dell Computer Corporation, Data General a division of EMC Corporation, Compaq Computer Corporation, Silicon Graphics Inc., and International Business Machines Corporation) DISCLAIM ALL LIABILITY FOR COST OF PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, LOST PROFITS, LOSS OF USE, LOSS OF DATA OR ANY INCIDENTAL, CONSEQUENTIAL, DIRECT, INDIRECT, OR SPECIAL AMAGES, WHETHER UNDER CONTRACT, TORT, WARRANTY OR OTHERWISE, ARISING IN ANY WAY OUT OF USE OR RELIANCE UPON THIS SPECIFICATION OR ANY INFORMATION HEREIN.

The Promoters disclaim all liability, including liability for infringement of any proprietary rights, relating to use of information in this specification. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted herein.

This specification and the information herein is the confidential and trade secret information of the Promoters. Use, reproduction and disclosure of this specification and the information herein is subject to the terms of the S.S.I. Specification Adopter's Agreement.

Copyright ã Intel Corporation, Dell Computer Corporation, Compaq Computer Corporation, Silicon Graphics Inc., International Business Machines Corporation, 2000.

- 2 -

Image 2
Contents SSI Disclaimer Contents Tables Agency RequirementsPurpose Conceptual OverviewDefinitions/Terms/Acronyms RequiredMechanical Overview Required OptionalOptional Optional Chassis Mounting FeaturesAirflow Requirements RecommendedAC Input Requirements Temperature RequirementsAC Inlet Connector Redundant AC InletsEfficiency AC Input Voltage SpecificationOutput Minimum Power Efficiency AC Input RatingAC Inrush AC Line DropoutAC Line Fuse AC Line Sag Transient Performance AC Line Transient SpecificationAC Line Fast Transient Specification AC Line Surge Transient PerformanceRequired Baseboard power connector DC Output SpecificationOutput Connectors Optional Processor Power ConnectorPeripheral Power Connectors Required Peripheral Power ConnectorsRequired Floppy Power Connector P9 Floppy Power ConnectorGrounding Optional Server Signal ConnectorServer Signal Connector Remote SenseVoltage Minimum Continuous Maximum Continuous Peak Output Power/Currents350 W Load Ratings 480 W Load RatingsVoltage Regulation Limits Voltage RegulationStandby Outputs Ripple / Noise Dynamic LoadingCapacitive Loading Transient Load RequirementsRipple and Noise RedundancyHot Swap Requirements +3.3 +12 +5 VSBSSI Description Timing RequirementsOutput Voltage Timing Turn On/Off Timing Recommended DescriptionTurn On/Off Timing 240VA Protection Protection CircuitsCurrent Limit Over Current ProtectionOver Voltage Limits Over Temperature ProtectionOver Voltage Protection Output VoltagePwok delay Control and Indicator FunctionsPson # Signal Characteristic Signal Type PSON#Pwok Power OK Pwok Signal CharacteristicsModule FRU Data Module FRU Data Format Field Replacement Unit FRU SignalsSMBus Communication Product Info AreaMultiRecord Area Field Name PS Info Field Information DefinitionPower Supply LEDs LED IndicatorsLED Indicators Mtbf 10Agency Requirements