Intel ERP2U Control and Indicator Functions, Pson#, Pson # Signal Characteristic Signal Type

Page 26

SSI

ERP2U Power Supply Design Guide, V1.0

8Control and Indicator Functions

The following sections define the input and output signals from the power supply.

Signals that can be defined as low true use the following convention:

signal# = low true

8.1PSON#

STATUS

Required

The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the +3.3 V, +5 V, +12 V, and -12 V power rails. When this signal is not pulled low by the system, or left open, the outputs (except the +5 VSB and Vbias) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. Refer to Figure 3 for timing diagram.

 

Table 23: PSON# Signal Characteristic

 

Signal Type

 

Accepts an open collector/drain input from the system.

 

Pull-up to VSB located in power supply.

 

 

 

 

 

 

PSON# = Low

 

ON

 

PSON# = Open or High

OFF

 

 

 

MIN

MAX

Logic level low (power supply ON)

0 V

1.0 V

 

 

Logic level high (power supply OFF)

2.0 V

5.25 V

 

 

Source current, Vpson = low

 

4 mA

 

 

Power up delay:

Tpson_on_delay

5 ms

400 ms

 

 

PWOK delay:

T pson_pwok

 

50 ms

 

 

Disabled

Enabled

Hysteresis ³ 0.3V and/or other de-bounce method

£ 1.0 V

³ 2.0 V

PS is

PS is

enabled

disabled

0V

1.0V

2.0V

5.25V

Figure 4: PSON# Signal Characteristics

- 26 -

Image 26
Contents SSI Disclaimer Contents Tables Agency RequirementsPurpose Conceptual OverviewDefinitions/Terms/Acronyms RequiredMechanical Overview Required OptionalOptional Optional Chassis Mounting FeaturesAirflow Requirements RecommendedAC Input Requirements Temperature RequirementsAC Inlet Connector Redundant AC InletsEfficiency AC Input Voltage SpecificationOutput Minimum Power Efficiency AC Input RatingAC Inrush AC Line DropoutAC Line Fuse AC Line Sag Transient Performance AC Line Transient SpecificationAC Line Fast Transient Specification AC Line Surge Transient PerformanceRequired Baseboard power connector DC Output SpecificationOutput Connectors Optional Processor Power ConnectorPeripheral Power Connectors Required Peripheral Power ConnectorsRequired Floppy Power Connector P9 Floppy Power ConnectorGrounding Optional Server Signal ConnectorServer Signal Connector Remote SenseVoltage Minimum Continuous Maximum Continuous Peak Output Power/Currents350 W Load Ratings 480 W Load RatingsVoltage Regulation Limits Voltage RegulationStandby Outputs Ripple / Noise Dynamic LoadingCapacitive Loading Transient Load RequirementsRipple and Noise RedundancyHot Swap Requirements +3.3 +12 +5 VSBSSI Description Timing RequirementsOutput Voltage Timing Turn On/Off Timing Recommended DescriptionTurn On/Off Timing 240VA Protection Protection CircuitsCurrent Limit Over Current ProtectionOver Voltage Limits Over Temperature ProtectionOver Voltage Protection Output VoltagePwok delay Control and Indicator FunctionsPson # Signal Characteristic Signal Type PSON#Pwok Power OK Pwok Signal CharacteristicsModule FRU Data Module FRU Data Format Field Replacement Unit FRU SignalsSMBus Communication Product Info AreaMultiRecord Area Field Name PS Info Field Information DefinitionPower Supply LEDs LED IndicatorsLED Indicators Mtbf 10Agency Requirements