Intel ERP2U manual Output Power/Currents, W Load Ratings

Page 16

SSI

ERP2U Power Supply Design Guide, V1.0

6.4Output Power/Currents

STATUS

Recommended

The following tables define the power and current ratings for two recommend power levels. Depending upon the system design, the power supply modules may have only three outputs (+12V, -12V, and 5VSB) or the full five outputs (+3.3V, +5V, +12V, -12V, and 5VSB). If only three outputs are provided from the module, the cage shall have additional DC/DC converters to generate +5V and +3.3V from the +12V provided by the modules. The combined output power of all outputs from the cage shall not exceed the rated output power. The power assembly shall meet both static and dynamic voltage regulation requirements over the full load ranges. The power sub-assembly shall supply redundant power over the full load ranges.

Table 11: 350 W Load Ratings

Voltage

Minimum Continuous

Maximum Continuous

Peak

+3.3 V 7

0.5 A

20 A

 

 

 

 

 

+5 V 7

2.0 A

20 A

 

 

 

 

 

+12V2 (baseboard connector)

0.5 A

12 A

15 A

 

 

 

 

+12V3 (peripheral connectors)

1.0 A

13 A

15A

 

 

 

 

-12 V

0 A

0.5 A

 

 

 

 

 

+5 VSB

0.1 A

2.0 A

 

 

 

 

 

1Maximum continuous total DC output power should not exceed 350 W.

2Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 115 W.

3Maximum Peak total DC output power should not exceed 410 W.

4Peak power and current loading shall be supported for a minimum of 10 second.

5Maximum combined current for the 12 V outputs shall be 25 A.

6Maximum 12V combined peak current shall be 30A.

7The 3.3V and 5V may be supply by the module or DC/DC converters powered from +12V in the cage.

Table 12: 480 W Load Ratings

Voltage

Minimum Continuous

Maximum Continuous

Peak

+3.3 V 7

0.5 A

20 A

 

 

 

 

 

+5 V 7

2.0 A

20 A

 

 

 

 

 

+12V1 (processor connector)

0.5 A

15 A

18 A

 

 

 

 

+12V2 (baseboard connector)

1.0 A

12 A

 

 

 

 

 

+12V3 (peripheral connectors)

0.5 A

10 A

16 A

 

 

 

 

-12 V

0 A

0.5 A

 

 

 

 

 

+5 VSB

0.1 A

2.0 A

 

 

 

 

 

1.Maximum continuous total DC output power should not exceed 480 W.

2.Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 115 W.

3.Maximum Peak total DC output power should not exceed 620 W.

4.Peak power and current loading shall be supported for a minimum of 10 second.

5.Maximum combined current for the 12 V outputs shall be 37 A.

6.Maximum 12V combined peak current shall be 46 A.

7.The 3.3V and 5V may be supply by the module or DC/DC converters powered from +12V in the cage.

-16 -

Image 16
Contents SSI Disclaimer Contents Tables Agency RequirementsPurpose Conceptual OverviewDefinitions/Terms/Acronyms RequiredMechanical Overview Required OptionalOptional Chassis Mounting Features Airflow RequirementsOptional RecommendedTemperature Requirements AC Inlet ConnectorAC Input Requirements Redundant AC InletsAC Input Voltage Specification Output Minimum Power EfficiencyEfficiency AC Input RatingAC Line Fuse AC Line DropoutAC Inrush AC Line Transient Specification AC Line Fast Transient SpecificationAC Line Sag Transient Performance AC Line Surge Transient PerformanceDC Output Specification Output ConnectorsRequired Baseboard power connector Optional Processor Power ConnectorRequired Peripheral Power Connectors Required Floppy Power ConnectorPeripheral Power Connectors P9 Floppy Power ConnectorOptional Server Signal Connector Server Signal ConnectorGrounding Remote SenseOutput Power/Currents 350 W Load RatingsVoltage Minimum Continuous Maximum Continuous Peak 480 W Load RatingsStandby Outputs Voltage RegulationVoltage Regulation Limits Dynamic Loading Capacitive LoadingRipple / Noise Transient Load RequirementsRedundancy Hot Swap RequirementsRipple and Noise +3.3 +12 +5 VSBSSI Output Voltage Timing Timing RequirementsDescription Turn On/Off Timing Recommended DescriptionTurn On/Off Timing Protection Circuits Current Limit240VA Protection Over Current ProtectionOver Temperature Protection Over Voltage ProtectionOver Voltage Limits Output VoltageControl and Indicator Functions Pson # Signal Characteristic Signal TypePwok delay PSON#Pwok Power OK Pwok Signal CharacteristicsField Replacement Unit FRU Signals SMBus CommunicationModule FRU Data Module FRU Data Format Product Info AreaMultiRecord Area Field Name PS Info Field Information DefinitionLED Indicators LED IndicatorsPower Supply LEDs Mtbf 10Agency Requirements