Intel SR9000MK4U manual Power and Electrical Warnings, Power Cord Warnings

Page 220

Power and Electrical Warnings

Cautions:

The power button, indicated by the stand-by power marking, DOES NOT completely turn off the system AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are unplugged. Make sure the AC power cord(s) is/are unplugged before you open the chassis, or add or remove any non hot-plug components.

Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply.

Some power supplies in Intel® servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.

The power supply in this product contains no user-serviceable parts. Do not open the power supply. Hazardous voltage, current and energy levels are present inside the power supply. Return to manufacturer for servicing.

When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server.

To avoid risk of electric shock, turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it.

Power Cord Warnings

If an AC power cord was not provided with your product, purchase one that is approved for use in your country.

Caution: To avoid electrical shock or fire, check the power cord(s) that will be used with the product as follows:

Do not attempt to modify or use the AC power cord(s) if they are not the exact type required to fit into the grounded electrical outlets

The power cord(s) must meet the following criteria:

The power cord must have an electrical rating that is greater than that of the electrical current rating marked on the product.

The power cord must have safety ground pin or contact that is suitable for the electrical outlet.

The power supply cord(s) is/are the main disconnect device to AC power. The socket outlet(s) must be near the equipment and readily accessible for disconnection.

The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided with a suitable earth ground.

198

Intel® Server System SR9000MK4U Product Guide

Image 220
Contents Intel Server System SR9000MK4U Product Guide Intel Order Number D71314-004Disclaimer Safety Information 重要安全指导 Intel Server System SR9000MK4U Product Guide Intel Server System SR9000MK4U Product Guide About this Manual Manual OrganizationProduct Accessories Additional Information and SoftwareAdditional Information and Software For this information or Use this Document or SoftwareSee also the Resource CD that came with your server system Powering On the System Power Powering the System On and OffPowering Off the System Power Contents Xii Configuration Software and Utilities Appendix a Console Setup 163 Appendix F Getting Help Xvi Intel Server System SR9000MK4U Three Dimensional View List of FiguresRemoving Optical Drive from Server Checking the Backplane Cover Latches Sata Connections on Hard Drive Backplane 168 List of Tables Xxii Characteristics Specifications Intel Server System SR9000MK4U Chassis OverviewFeature Comment Chassis Feature SummaryChassis Description External Chassis Features Chassis Front Chassis Front ViewFront Panel Controls and Indicators Front PanelOptical Drive Bay Hot-swap Hard Drive BaySAS Hard Drive LED Details LED Color State DescriptionCallout Memory BoxLED State Description Chassis Rear Chassis Rear ViewNIC LEDs Color State DescriptionInternal Layout Open System, Top ViewInternal Chassis Features Power Supply SubsystemPower Supply Configuration AC Input Current Redundancy Hot-swap Remarks See NotePower Supply Indicators Cooling Fan Indicator Cooling SubsystemPCI Card Slot Indicator PCI Card SlotIntel Server System SR9000MK4U Product Guide Block Diagram Intel Server System SR9000MK4U Board Set OverviewMain Board Main Board LayoutMain Board Components Board Component Description LocationSIO Main Board External I/O Connectors Main Board Internal I/O ConnectorsBoard Connector Description Location Board Location Connector DescriptionConfiguration Restrictions Configuration RestrictionsIntel Graphics Card Voltage Mounted Redundancy Restriction Itanium 533 MTS 667 MTSProcessor Configurations Configuration Processor Number SocketMemory Box Card Memory Box Card ConnectorsBoard Location Component Description Dimm Configurations Dimm Locations Top View of Memory BoxMemory Number Bios Set-Up Redundancy Mode To One NDC SupportMemory Operational Modes HotMMR Memory Upgrade Path Hard Drive Backplane Hard Drive Backplane Top ViewFront Panel Board Hard Drive PopulationFront Panel Board Connectors DVDIntel Server System SR9000MK4U Product Guide Installing and Removing Components Tools NeededInstalling and Removing the Front Bezel Removing the Front BezelInstalling the Front Bezel Installing the Front BezelInstalling and Removing the Top Cover Removing the Top CoverInstalling and Removing a Hard Drive Installing the Top CoverInstalling a Hard Drive Pulling Down on the Hard Drive Carrier LeverMounting a Hard Drive Removing a Hard Drive Unmounting a Hard Drive Installing and Removing a Memory Box Hot-swapping a Hard DriveInstalling a Memory Box Removing the Memory Box Filler PanelInstalling the Memory Box Removing a Memory Box Removing the Memory BoxHot-swapping a Memory Box Intel Server System SR9000MK4U Product Guide Installing and Removing DIMMs Dimm Installation GuidelinesInstalling DIMMs Removing DIMMs Installing and Removing an Optical Drive Installing an Optical DriveAttaching the Optical Drive to the Bracket Removing the Optical Drive Removing Optical Drive from ServerRemoving the Optical Drive from the Bracket Installing and Removing a Fan Installing a FanInstalling a Fan Removing a Fan Removing a FanFan Fault LED Hot-swapping a FanInstalling and Removing a PCI Card Installing a PCI CardUnlocking a PCI Card Lock PCI Tail Lock Locking a PCI Card into Place Removing a PCI Card Opening a PCI Caution PlateReleasing the PCI Card from the Tail Lock Installing a PCI Slot Cover Close the PCI caution plate. See the figure below Locating the Lens Switch and PCI Card LED Hot-Plugging a PCI CardInstalling and Removing a Power Supply Installing a Power SupplyRemoving a Power Supply Filler Removing a Power Supply Locking the Power Supply into PlaceOpening the Power Supply Levers Installing a Power Supply Filler Hot-swapping a Power Supply Power Supply LED IndicatorsRemoving the Front Control Panel and Optical Drive Assembly Removing the Front Control Panel and Optical Drive AssemblyAF001212 Installing and Removing the Power Supply Box Removing the Power Supply BoxLocating the CPU1 / CPU2 MVR Connection Loosening the Exterior Captive Screws Lifting the Power Supply Box from System Installing the Power Supply Box Inserting the Rear of Power Supply BoxTightening the Internal Power Supply Box Screws Connecting the IDE and Sata Cables Installing and Removing the Power Supply Support Removing the Power Supply SupportLoosening the Power Supply Support Captive Screws Installing the Power Supply Support Setting the Power Supply Support into PlaceTightening the Power Supply Support Screws Installing and Removing the Hard Drive Backplane Cover Removing the Hard Drive Backplane CoverInstalling the Hard Drive Backplane Cover Installing the Hard Drive Backplane CoverInstalling and Removing the KVM Card Removing the KVM CardInstalling the KVM Card Locating the KVM CardInstalling and Removing the PCI Card Divider Removing the PCI Card DividerRemoving the PCI Card Divider Installing the PCI Card Divider Installing the PCI DividerLocating the CPU1 / CPU2 MVR Connection Installing and Removing the Air Flow Guide Removing the Air Flow GuideRemoving the Air Flow Guide Installing the Air Flow Guide Installing the Air Flow GuideInstalling and Removing the Fan Box Removing the Fan BoxLoosening the Exterior Screws Loosening the Interior Screws Installing the Fan Box Installing the Fan BoxTightening the Internal Fan Box Screws Installing and Removing the Hard Drive Backplane Removing the Hard Drive Backplane104 Intel Server System SR9000MK4U Product Guide Loosening the Hard Drive Backplane Screws Removing the Hard Drive Backplane from System Installing the Hard Drive Backplane Installing the Hard Drive BackplaneAttaching the Hard Drive Backplane to the System Intel Server System SR9000MK4U Product Guide 109 Installing and Removing a Processor Processor Assembly ComponentsRemoving a Processor Removing the MVR Handles Installing the Processor Exposing the Thermal Interface Material Installing the Pin Shroud over the Processor Setting the Processor over the Heat Sink Installing the Bolster Plate onto the Processor Attaching the Processor and Heat Sink to the Main Board Removing the Protective Cover from the LGA Terminal Attaching the MVR to the Processor Assembly Intel Server System SR9000MK4U Product Guide 121 Disassembling a Processor Assembly Installing the LGA Terminal CoverRemoving the Bolster Plate from the Processor Removing the Spring Clip Installing and Removing the Mounting Plate Removing the Mounting PlateLifting the Mounting Plate from the System Installing the Mounting Plate Setting the Mounting Plate into Place128 Intel Server System SR9000MK4U Product Guide Installing Chassis Handles Installing and Removing Chassis HandlesRemoving Chassis Handles 130 Intel Server System SR9000MK4U Product Guide Configuration Software and Utilities Extensible Firmware Interface EFI Boot ManagerBoot Maintenance Menu Options Option DescriptionFor this option Extensible Firmware Interface EFI Shell EFI Shell Commands Command Description136 Intel Server System SR9000MK4U Product Guide LSI* SAS Utility Formatting a Hard DriveSelect the hard drive and press the D key Format Clearing the Cmos Upgrading the FirmwareFirmware Update Block Diagram How to Use Fwupdate Fwupdate File Path ExampleCommand Line Description Option FunctionFwupdate Execution Screen Execution ScreenStarting Setup Using System SetupRecording Your Setup Settings Navigating Setup Utility Screens Using Setup ScreensPrimary Setup Screens Primary ScreensMain Setup Screen Primary Menu Item Sub Menu Item Option DescriptionProcessor Memory ScreenProcessor Screen Memory ScreenDevices Screen Devices ScreenPrimary Menu Item Sub Menu Item Options Description Server Management Screen Server Management ScreenCOM1 Console Redirection Configuring Serial-Over LAN System Information ScreenChoose Console Redirection Troubleshooting Initial Troubleshooting StepsTroubleshooting Guide Location Symptom Solution154 Intel Server System SR9000MK4U Product Guide Troubleshooting Guide State Transition Diagram Collecting System State InformationPower Off State EFI Shell Working State How to Read the Post Codes Location of Post Code LEDHow to Use Selview to Read the System Event Log How to Collect System and Error LogsCollecting System and Error Logs from a Linux* System Collecting System and Error Logs from a Windows* SystemIntel Server System SR9000MK4U Product Guide 161 Taking Corrective Action Appendix a Console Setup On-board VGA164 Intel Server System SR9000MK4U Product Guide Serial Console Select Console Redirection from the Server Management Menu166 Intel Server System SR9000MK4U Product Guide Appendix B Cabling Working with Ribbon CablesConnections Near Power Supply Box and PCI Card Divider Cable ConnectionsIDE Connection and Cable Routing 170 Intel Server System SR9000MK4U Product Guide Code Descriptions Classification Operation to Recover Appendix C Post Codes172 Intel Server System SR9000MK4U Product Guide Intel Server System SR9000MK4U Product Guide 173 174 Intel Server System SR9000MK4U Product Guide Intel Server System SR9000MK4U Product Guide 175 176 Intel Server System SR9000MK4U Product Guide Code Description Operation to Recover 178 Intel Server System SR9000MK4U Product Guide Error Post Codes Generated by SAL Code Description Classification Operation to Recover180 Intel Server System SR9000MK4U Product Guide Appendix D Installation/Assembly Safety Instructions English182 Intel Server System SR9000MK4U Product Guide Deutsch 184 Intel Server System SR9000MK4U Product Guide Français Page Español 188 Intel Server System SR9000MK4U Product Guide Italiano Page Page 192 Intel Server System SR9000MK4U Product Guide Appendix E Safety Information 194 Intel Server System SR9000MK4U Product Guide Server Safety Information Hot-swap Power SupplySafety Warnings and Cautions Intended Application UsesEquipment Handling Practices Site SelectionPower and Electrical Warnings Power Cord WarningsSystem Access Warnings Electrostatic Discharge ESD Rack Mount WarningsBattery Replacement Other HazardsCooling and Airflow Laser Peripherals or DevicesSicherheitshinweise für den Server Sicherheitshinweise und VorsichtsmaßnahmenZielbenutzer der Anwendung StandortauswahlWarnungen zu Netzspannung und Elektrizität Handhabung von GerätenWarnhinweise für den Systemzugang Hinweis für NetzkabelWarnhinweise für Racks Elektrostatische Entladungen ESDAndere Gefahren BatterieaustauschKühlung und Luftstrom Laser-Peripheriegeräte oder -KomponentenConsignes de sécurité sur le serveur Sécurité avertissements et mises en gardeDomaines d’utilisation prévus Sélection d’un emplacementPratiques de manipulation de l’équipement Alimentation et avertissements en matière d’électricité Avertissements sur le cordon d’alimentationAvertissements sur l’accès au système Décharges électrostatiques ESD Remplacement de la pileAutres risques Refroidissement et ventilation Périphériques laserInformación de seguridad del servidor Advertencias y precauciones sobre seguridadSelección de la ubicación Aplicaciones y usos previstosManipulación del equipo Advertencias de alimentación y eléctricas Advertencias sobre el cable de alimentaciónAdvertencias el acceso al sistema Descarga electrostática ESD Sustitución de la bateríaEnfriamiento y circulación de aire Periféricos o dispositivos láser简体中文 服务器安全信息 设备操作规范 系统使用警告 机架固定件警告 其他危险 World Wide Web Telephone Appendix F Getting HelpCanada Europe Japan Asia-Pacific RegionLatin America Panama 228 Intel Server System SR9000MK4U Product Guide Appendix G Regulatory and Compliance Information Product Safety ComplianceProduct Regulatory Compliance Product EMC Compliance Class a Compliance Certifications / Registrations / DeclarationsElectromagnetic Compatibility Notices FCC Verification Statement USAEurope CE Declaration of Conformity Industry Canada ICES-003Vcci Japan RRL Korea Bsmi TaiwanCnca CCC China Regulated Specified Components Restriction of Hazardous Substances RoHS Compliance End of Life / Product Recycling236 Intel Server System SR9000MK4U Product Guide