Konica Minolta IV instruction manual

Page 45

Color-depth list box: this option specifies the color depth of the scanned image between 8 bit, 16 bit, and 16-bit linear for each RGB channel. Because 16-bit linear color depth does not make any gamma corrections, the scan of a negative will produce a negative image. 16-bit and 16-bit linear images can only be saved in the TIFF file format. Some image-processing application cannot open 16-bit image files.

Multi-sample list box: multi-sample scans reduce random noise in the image by analyzing the data of each sample scan; 2, 4, 8, and 16 samples can be made. The more samples taken, the less random noise in the image and the longer the scanning time.

Retouching level: to adjust the degree of Auto Dust Brush processing. See page 38.

35mm-index-scan-priority radio button: this option allows the selection of high- speed index scans or a quality index scans with prescans. Simply click the appropriate radio button.

Speed

Quality

Only makes index thumbnails. Autofocus is disabled during the index scan.

Makes an index thumbnail and prescan of each image. Scanning time is increased.

Prescan size: to change the size of the prescan image.

Color matching: this controls color reproduction on output devices such as monitors and printers. For detailed information, see the color matching section on page 80.

Rotate-frames-180-degrees check box: to rotate all APS thumbnails 180 degrees in the index scan tab.

OK button: to apply the preference settings and close the window.

Cancel button: to cancel any settings made and close the window.

Help button: to open the help window.

45

Image 45
Contents Page Selective-color palette Tone-curve correctionsBefore YOU Begin For Proper and Safe USE DiMAGE Scan Dual Table of Contents Page Table of Contents Installation Before installing the DiMAGE Scan UtilityNames of Parts DiMAGE Scan system requirements Adobe Photoshop Elements Additional memory requirementsWindows Page Macintosh Page Scanner Setup Before connecting the scanner to a computerConnecting the USB cable Connecting the AC adapter Disconnecting the scannerTurning on the scanner Loading the Film Holders Where is the emulsion?Handling film Loading 35mm film stripsLoading a film holder into the scanner Loading mounted slidesUsing the APS Adapter AD-10 sold separately APS Ejecting a film holderDimage Scan Launcher Launching the Easy Scan Utility Easy Scan UtilityScanner Notes Macintosh Using the Easy Scan UtilityOn next Easy Scan Utility Page Basic Scanning Launching the DiMAGE Scan UtilityScanning basics Main window and index scan tab Scanner setupSelecting index thumbnails Making an index scanFit-to-window button Flip and rotate imagesMaking a prescan Main window and prescan tabMagnifying tool Grab toolAuto cropping CHP button APS filmMaking the final scan Tiff BMP Pict Main window and image-correction tab Basic Image ProcessingPixel Polish Auto Dust Brush retouching level Auto Dust BrushVariation palette Brightness, contrast, and color balance palette Green An introduction to colorUndoing and redoing image corrections Comparing pre and post-correction imagesQuitting the DiMAGE Scan Utility Advanced Scanning Setting scanner preferencesPage Exposure-control tab Loading exposure settings Saving exposure settingsReverse frame order More index scan functionsSaving the index thumbnails Saving an index fileLoading an index file Point AF Autofocus More prescan functionsManual focus Manual cropping AE area selection AutoexposureInputting scan settings manually About resolution and output size Scan setting examples Deleting a Job Saving scan settings as a JobMore image-processing tools Advanced Image ProcessingPrescan display Sample display area Digital Grain DissolverTone curve and histogram palette Using tone curvesDrawing tone curves by freehand About the tone curve Short guide to tone curve correctionsIncreasing image contrast Histogram corrections Tone curve / histogram auto setting Konica Minolta History Short guide to histogram correctionsPage White, gray, and black point corrections Tracking image corrections Snapshot button Setting the white and black-point valuesHue, saturation, and lightness palette About RGB and CMY With mask Original image Unsharp maskLoading image-correction Jobs Saving image correctionsCustom Wizard Page Batch Scan Utility Page Advanced Batch Scan setup Page Color Matching Setting the output color spaceNtsc CIE RGB Output color spacesScanner color profiles Setting the monitor ICC profileOutput Color Space Monitor RGB Color matching recommendationsBefore installing the plug-in Installation WindowsAuto Dust Brush PLUG-IN Page Installation Macintosh Using the Auto Dust Brush plug-in Auto Dust Brush PLUG-IN Glossary of common terms AppendixUninstalling the DiMAGE Scan Software Windows Installed files and foldersJob file list 35mm Troubleshooting Checking software installation Windows Technical Specifications Warranty and product registration Technical supportRecord keeping Image processing Image Data SheetHue corrections