Inputting scan settings manually

Settings for the final scan can be made in the index scan or prescan windows.

Job-name list box

Load Job button

Save Job button

Input-resolution list box

Output-resolution list box

Input-size text boxes

Input-size lock button

Magnification text box

Output-size text boxes

Output-size lock button

Unit list box

Reset button

Image-size display

Input-resolution list box: values can be selected among the drop-down list or be entered into the box directly. The input-resolution range is from 200 dpi to the maximum resolution of 3200 dpi.

Output-resolution list box: values can be selected among the drop-down list or be entered into the box directly. Output-resolution cannot be entered if pixel is selected in the unit list box.

Input-size text box: input size is determined by either the cropping frame dimensions or the values entered in the width and height boxes. The cropping frame will adjust to any value entered. Input-size cannot be entered if pixel is selected in the unit list box.

Input-size lock button: to lock the input values. The cropping frame can be moved, but not resized while this button is clicked. Clicking the button again releases the lock. The input-size lock button cannot be used if pixel is selected in the unit list box.

Magnification text box: to set image magnification. This value is based on input and output resolution, or output and input size. The magnification text box cannot be used if pixel is selected in the unit list box.

54 ADVANCED SCANNING

Image 54
Contents Page Tone-curve corrections Selective-color paletteBefore YOU Begin For Proper and Safe USE DiMAGE Scan Dual Table of Contents Page Table of Contents Installation Before installing the DiMAGE Scan UtilityNames of Parts DiMAGE Scan system requirements Additional memory requirements Adobe Photoshop ElementsWindows Page Macintosh Page Scanner Setup Before connecting the scanner to a computerConnecting the USB cable Connecting the AC adapter Disconnecting the scannerTurning on the scanner Handling film Where is the emulsion?Loading the Film Holders Loading 35mm film stripsLoading mounted slides Loading a film holder into the scannerUsing the APS Adapter AD-10 sold separately Ejecting a film holder APSDimage Scan Launcher Easy Scan Utility Launching the Easy Scan UtilityUsing the Easy Scan Utility Scanner Notes MacintoshOn next Easy Scan Utility Page Basic Scanning Launching the DiMAGE Scan UtilityScanning basics Scanner setup Main window and index scan tabMaking an index scan Selecting index thumbnailsFlip and rotate images Fit-to-window buttonMain window and prescan tab Making a prescanAuto cropping Grab toolMagnifying tool CHP button APS filmMaking the final scan Tiff BMP Pict Basic Image Processing Main window and image-correction tabPixel Polish Auto Dust Brush Auto Dust Brush retouching levelVariation palette Brightness, contrast, and color balance palette An introduction to color GreenComparing pre and post-correction images Undoing and redoing image correctionsQuitting the DiMAGE Scan Utility Setting scanner preferences Advanced ScanningPage Exposure-control tab Saving exposure settings Loading exposure settingsMore index scan functions Reverse frame orderSaving the index thumbnails Saving an index fileLoading an index file More prescan functions Point AF AutofocusManual focus Manual cropping Autoexposure AE area selectionInputting scan settings manually About resolution and output size Scan setting examples Saving scan settings as a Job Deleting a JobAdvanced Image Processing More image-processing toolsDigital Grain Dissolver Prescan display Sample display areaUsing tone curves Tone curve and histogram paletteDrawing tone curves by freehand Short guide to tone curve corrections About the tone curveIncreasing image contrast Histogram corrections Tone curve / histogram auto setting Short guide to histogram corrections Konica Minolta HistoryPage White, gray, and black point corrections Setting the white and black-point values Tracking image corrections Snapshot buttonHue, saturation, and lightness palette About RGB and CMY Unsharp mask With mask Original imageSaving image corrections Loading image-correction JobsCustom Wizard Page Batch Scan Utility Page Advanced Batch Scan setup Page Setting the output color space Color MatchingOutput color spaces Ntsc CIE RGBSetting the monitor ICC profile Scanner color profilesColor matching recommendations Output Color Space Monitor RGBBefore installing the plug-in Installation WindowsAuto Dust Brush PLUG-IN Page Installation Macintosh Using the Auto Dust Brush plug-in Auto Dust Brush PLUG-IN Appendix Glossary of common termsUninstalling the DiMAGE Scan Software Installed files and folders WindowsJob file list 35mm Troubleshooting Checking software installation Windows Technical Specifications Warranty and product registration Technical supportRecord keeping Image Data Sheet Image processingHue corrections