TECHNICAL SPECIFICATIONS

Scan type:

Moving film, fixed sensor, single-pass scan

Film type:

Negative and positive, color and monochrome

Film formats:

35mm and APS film.

Scanning dimensions:

35mm - 24.76 x 37.14mm (3120 x 4680 pixels)

 

APS - 17.33 x 30.09mm (2184 x 3782 pixels)

Optical input resolution:

3200 dpi

Image sensor:

3-line primary-color CCD with 5340 pixels/line

A/D conversion:

16 bit

Color depth:

8 bit and 16 bit per color channel

Dynamic range:

3.6

Light source:

3-wavelength cold cathode fluorescent tube

Focusing:

Autofocus, point AF, and manual focus

Interface:

USB 2.0 (USB 1.1 compatible)

Power consumption:

Max. 30 W

Dimensions (W x H x D):

145 x 100 x 326 mm

 

5.7 x 3.9 x 12.8 in

Weight (approx.):

1.5 kg / 3.3 lb

Operating environment:

10° - 35°C (50° - 95°F), 15-80% humidity without

 

condensation

Storage environment:

-20° - 60°C (-4° - 140°F), 15-80% humidity without

 

condensation

Scan times (approx.):

Prescan: 6 sec. (Windows), 8 sec. (Macintosh)

 

Scan: 21 seconds

 

Scanning time changes according to the

 

preferences used. Scanning time can be longer for

 

negative film than positive film.

Test conditions:

Slide Mount Holder, Color positive film, no

 

autoexposure, no image correction, 3200dpi 8-bit

 

scan.

 

Windows: Pentium IV 3.2 GHz, Windows XP

 

Professional, 1.0GB RAM, 86GB hard disk space,

 

built-in USB 2.0 port, Adobe Photoshop ver. 7.0.1.

 

Macintosh: PowerPC G5 1.8 GHz, Mac OS X

 

10.3.1, 512MB RAM, 16GB hard disk space, Apple

 

USB 2.0 port, Adobe Photoshop ver. 7.0.1.

Specifications are based on the latest information available at the time of printing and are subject to change without notice.

96 TECHNICAL SPECIFICATIONS

Image 96
Contents Page Tone-curve corrections Selective-color paletteBefore YOU Begin For Proper and Safe USE DiMAGE Scan Dual Table of Contents Page Table of Contents Installation Before installing the DiMAGE Scan UtilityNames of Parts DiMAGE Scan system requirements Additional memory requirements Adobe Photoshop ElementsWindows Page Macintosh Page Scanner Setup Before connecting the scanner to a computerConnecting the USB cable Connecting the AC adapter Disconnecting the scannerTurning on the scanner Where is the emulsion? Loading the Film HoldersHandling film Loading 35mm film stripsLoading mounted slides Loading a film holder into the scannerUsing the APS Adapter AD-10 sold separately Ejecting a film holder APSDimage Scan Launcher Easy Scan Utility Launching the Easy Scan UtilityUsing the Easy Scan Utility Scanner Notes MacintoshOn next Easy Scan Utility Page Basic Scanning Launching the DiMAGE Scan UtilityScanning basics Scanner setup Main window and index scan tabMaking an index scan Selecting index thumbnailsFlip and rotate images Fit-to-window buttonMain window and prescan tab Making a prescanGrab tool Magnifying toolAuto cropping CHP button APS filmMaking the final scan Tiff BMP Pict Basic Image Processing Main window and image-correction tabPixel Polish Auto Dust Brush Auto Dust Brush retouching levelVariation palette Brightness, contrast, and color balance palette An introduction to color GreenComparing pre and post-correction images Undoing and redoing image correctionsQuitting the DiMAGE Scan Utility Setting scanner preferences Advanced ScanningPage Exposure-control tab Saving exposure settings Loading exposure settingsMore index scan functions Reverse frame orderSaving the index thumbnails Saving an index fileLoading an index file More prescan functions Point AF AutofocusManual focus Manual cropping Autoexposure AE area selectionInputting scan settings manually About resolution and output size Scan setting examples Saving scan settings as a Job Deleting a JobAdvanced Image Processing More image-processing toolsDigital Grain Dissolver Prescan display Sample display areaUsing tone curves Tone curve and histogram paletteDrawing tone curves by freehand Short guide to tone curve corrections About the tone curveIncreasing image contrast Histogram corrections Tone curve / histogram auto setting Short guide to histogram corrections Konica Minolta HistoryPage White, gray, and black point corrections Setting the white and black-point values Tracking image corrections Snapshot buttonHue, saturation, and lightness palette About RGB and CMY Unsharp mask With mask Original imageSaving image corrections Loading image-correction JobsCustom Wizard Page Batch Scan Utility Page Advanced Batch Scan setup Page Setting the output color space Color MatchingOutput color spaces Ntsc CIE RGBSetting the monitor ICC profile Scanner color profilesColor matching recommendations Output Color Space Monitor RGBBefore installing the plug-in Installation WindowsAuto Dust Brush PLUG-IN Page Installation Macintosh Using the Auto Dust Brush plug-in Auto Dust Brush PLUG-IN Appendix Glossary of common termsUninstalling the DiMAGE Scan Software Installed files and folders WindowsJob file list 35mm Troubleshooting Checking software installation Windows Technical Specifications Warranty and product registration Technical supportRecord keeping Image Data Sheet Image processingHue corrections