Setting the monitor ICC profile

The ICC profile for a specific monitor can be specified in the color-matching section of the Preferences dialog box. Refer to the monitor instruction manual for the profile name.

Click the use-monitor-ICC-profile check box.

Click the load ICC-profile button. The operating system’s file-open dialog box will open.

Locate and open the ICC profile for the monitor in use. The selected profile will be displayed in the preferences window. Click OK in the preferences window to set the ICC profile.

Monitor ICC profiles are located in the same folder as the scanner color profiles, see below. When using Mac OS X, the monitor profiles are in the following location: [Library] -> [ColorSync] -> [Profiles] -> [Displays].

Scanner color profiles

When installing the DiMAGE Scan Utility software, scanner color profiles will be automatically installed. These profiles have been included for advanced color matching with profile-to-profile conversions in sophisticated image-processing or DTP applications. Refer to the scanner notes section of the hardware manual for the profile for a specific scanner model.

Windows

(98, 98SE, Me) Windows

System

Color

 

 

 

 

 

Windows

 

 

 

 

 

 

 

 

MLTF3200.icc

 

 

 

 

 

 

 

 

(2000)

WINNT

System32

Spool

Drivers

Color

MLTF3200p.icc

 

 

 

 

Windows

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(XP)

Windows

System32

Spool

Drivers

Color

 

 

 

 

 

 

 

82 COLOR MATCHING

Image 82
Contents Page Tone-curve corrections Selective-color paletteBefore YOU Begin For Proper and Safe USE DiMAGE Scan Dual Table of Contents Page Table of Contents Before installing the DiMAGE Scan Utility InstallationNames of Parts DiMAGE Scan system requirements Additional memory requirements Adobe Photoshop ElementsWindows Page Macintosh Page Before connecting the scanner to a computer Scanner SetupConnecting the USB cable Disconnecting the scanner Connecting the AC adapterTurning on the scanner Handling film Where is the emulsion?Loading the Film Holders Loading 35mm film stripsLoading mounted slides Loading a film holder into the scannerUsing the APS Adapter AD-10 sold separately Ejecting a film holder APSDimage Scan Launcher Easy Scan Utility Launching the Easy Scan UtilityUsing the Easy Scan Utility Scanner Notes MacintoshOn next Easy Scan Utility Page Launching the DiMAGE Scan Utility Basic ScanningScanning basics Scanner setup Main window and index scan tabMaking an index scan Selecting index thumbnailsFlip and rotate images Fit-to-window buttonMain window and prescan tab Making a prescanAuto cropping Grab toolMagnifying tool CHP button APS filmMaking the final scan Tiff BMP Pict Basic Image Processing Main window and image-correction tabPixel Polish Auto Dust Brush Auto Dust Brush retouching levelVariation palette Brightness, contrast, and color balance palette An introduction to color GreenComparing pre and post-correction images Undoing and redoing image correctionsQuitting the DiMAGE Scan Utility Setting scanner preferences Advanced ScanningPage Exposure-control tab Saving exposure settings Loading exposure settingsMore index scan functions Reverse frame orderSaving an index file Saving the index thumbnailsLoading an index file More prescan functions Point AF AutofocusManual focus Manual cropping Autoexposure AE area selectionInputting scan settings manually About resolution and output size Scan setting examples Saving scan settings as a Job Deleting a JobAdvanced Image Processing More image-processing toolsDigital Grain Dissolver Prescan display Sample display areaUsing tone curves Tone curve and histogram paletteDrawing tone curves by freehand Short guide to tone curve corrections About the tone curveIncreasing image contrast Histogram corrections Tone curve / histogram auto setting Short guide to histogram corrections Konica Minolta HistoryPage White, gray, and black point corrections Setting the white and black-point values Tracking image corrections Snapshot buttonHue, saturation, and lightness palette About RGB and CMY Unsharp mask With mask Original imageSaving image corrections Loading image-correction JobsCustom Wizard Page Batch Scan Utility Page Advanced Batch Scan setup Page Setting the output color space Color MatchingOutput color spaces Ntsc CIE RGBSetting the monitor ICC profile Scanner color profilesColor matching recommendations Output Color Space Monitor RGBInstallation Windows Before installing the plug-inAuto Dust Brush PLUG-IN Page Installation Macintosh Using the Auto Dust Brush plug-in Auto Dust Brush PLUG-IN Appendix Glossary of common termsUninstalling the DiMAGE Scan Software Installed files and folders WindowsJob file list 35mm Troubleshooting Checking software installation Windows Technical Specifications Technical support Warranty and product registrationRecord keeping Image Data Sheet Image processingHue corrections