Sanyo VCC-WB4000 Access Level Settings, For Operator access level, For User access level

Page 24

L5AM2/US (VCC-WB4000) GB 2003, 6, 6

Network Camera (Wired LAN) Settings

Access Level Settings

When operating the network camera, you need to select an access level to either limit operations to only the monitoring of live images or to allow menu settings to be changed as well.

The access level setting depends on the “Username” and “Password” that are typed in after the wired LAN settings have been made. (p. 15)

The default access level is “Administrator” (ID3, 3333) which allows all operations to be carried out. Change the username and password to the desired access level while referring to the table below.

Table 1

Username/password

Access level

For Administrator access level

All operations and settings can be carried out.

Username: ID3

 

Password: 3333

 

For Operator access level

Username: ID2

Password: 2222

Only the following buttons can be operated.

For User access level

Username: ID1

Password: 1111

Only the following buttons can be operated.

The transmission setting menu in the live image screen is disabled.

In order to make it easier to refer to this Instruction Manual when carrying out the various camera operations, the usernames (_ID1_, _ID2_ and/or _ID3_) are indicated in the top-right corner of the page.

For example, if _ID3_ appears, then the operation is only available at the Administrator level.

English

– 23 –

Image 24
Contents VCC-WB4000 Network CameraContents Information to user For the customers in CanadaPour la clientèle canadienne Precautions FeaturesAccessories Operating environmentMonitor OUT connector Power indicatorName and Function of Each Part Lens mount capName and Function of Each Part Attaching the Lens Remove the lens mount cap Attach the CS mount-type lensFor C mount type Flange Back Adjustment Connections Basic ConnectionsConnecting to a LAN ConnectionsNetwork Camera Wired LAN Settings Installation of Plug-in Software to the Computer pWired LAN Settings p Computer Network SET Settings pNetwork Camera Wired LAN Settings Installation of Plug-in Software to the ComputerTurn on the power for the computer Click the OK buttonClick the Install button Uninstalling the plug-in softwarePlug-in software Browser Settings Cookie SettingsCamera uses cookies Wired LAN Settings Example Subnet mask setting TypeLanguage selection window Image quality mode select buttons Available settings Auto default settingInitial Camera Screen FineWireless LAN button Alarm buttonAlarm indicator Menu select buttonsLit orange alarm recording image playback is not possible Lit green alarm recording image playback is possibleRed indicator Grey indicatorResolution and Expansion settings default settings 640x480 Selection screen exampleSET button JImage display areaNetwork SET Settings Set the passwordClick the Network menu select button Network SpeedChanging a password When a password has been changedMAC Address display Changing the Access Level ID2 or ID3 Turn the camera off and then back on againAccess Level Settings For Operator access levelFor User access level Clock SET Settings Daylight Saving ModeTimezone Daylight SavingCamera Settings Live ImageCamera Title IrisCamera Settings Setting manual white balance ManualSetting the camera title DAY/NIGHT SettingsMode BurstAuto Mode Settings Color Mode SettingsSet Burst to OFF example Click the SET button Set Polarity to no exampleMode Settings Set AGC Gain to +12 dB example Click the SET buttonColor mode Timer mode Change the DAY/NIGHT setting to Color modeChange the DAY/NIGHT setting to Timer mode Connection example FigureAlarm Settings Click the Alarm menu select buttonAlarm Settings Alarm Buffering SET Setting External Alarm Sensor Setting Alarm ResolutionSet Alarm Buffering to ON, and then click the Detail button Set Alarm REC USE to USE and then click the SET buttonMotion Detector SET Settings Set the sensor marksExternal Alarm Sensor and Motion Detector Settings Motion Detector Level Sensitivity Setting Remote Alarm OperationsAlarm Output for a Specified Period Set Motion Detector Level to 2 exampleContinuous Alarm Output Pre-alarm/Post-alarm Recording Alarm detectedSet Buffering Area to PRE/POST 0/10 Set Buffering Area to PRE/POST 2/8Recording New Alarm Data Fixed Settings During Pre/Post-Alarm RecordingAlarm Data indicator green will illuminate Saving to an Expansion Memory CardInsert the expansion memory card Viewing Live Images Viewing Live Images Viewing the View Frame ScreenClick the View Frame menu select button Playing Back Alarm Data Playing Back Alarm Data in the Camera’s Internal MemoryDescriptions of Alarm Operation Buttons Frame RatePlaying Back Alarm Data Playing Back Alarm Images Stored in a ComputerClick the Alarm Data indicator while it is red or green Playing Back Expansion Memory Card ImagesResolution ENDPrevious Alarm Data Deleting Saving Live Images and Alarm Images Saving Alarm Images onto a Computer as Still ImagesSaving Live Images onto a Computer Saving Live Images and Alarm Images Saving All of a Single Alarm Event onto a ComputerWhen the File Download pop-up menu is displayed, click Save Click the Play button and then click the Download buttonWireless LAN SET Settings Camera wired LAN settings TCP/IP settingsWireless LAN device settings TCP/IP settings Camera wireless LAN settings TCP/IP settingsWireless LAN SET Settings Camera Wireless LAN SettingsDescription of Wireless LAN SET Screen Encipherment SettingsPPP Dial-up Settings PPP Connection to an Internet Service ProviderConnecting the camera and installing the software Double-click the Camset icon on the desktopPPP Dial-up Settings Click the SET to Camera buttonClick the Save Info File button Close the Camset windowDial to Provider Settings AuthenticationProvider TEL. no Dial from PC Setting PPP Connection from a ComputerCamera Computer Telephone lineMake the settings in the PPP setting screen Set the following itemsRS-232C Settings RS-232C SET Language SelectionClick the RS-232C menu select button Click the Language button to change the languageStatus Checking Click the Status menu select buttonFirmware Version SUB-MICROCOMPUTER VersionGlossary of Terms Glossary of Terms Pre-alarm and post-alarm recording Troubleshooting If the camera cannot be connectedIf you forget the IP Address Specifications Exclusions Printed on recycled paper 1AC6P1P2677 L5AM2/US 0603KP-CZ

VCC-WB4000 specifications

The Sanyo VCC-WB4000 is an advanced surveillance camera designed primarily for outdoor use, offering state-of-the-art features that cater to a variety of security needs. This robust model stands out for its high-resolution imaging capabilities combined with powerful technologies that ensure reliable performance in various lighting conditions.

At the heart of the VCC-WB4000 is its exceptional image sensor. The camera boasts a 1/3-inch CCD sensor, which delivers clear and detailed images with a resolution of up to 400 TV lines. This ensures that users can capture high-quality footage, even in challenging environments. Additionally, the camera’s 3x optical zoom lens allows for versatile viewing angles and the ability to focus on specific subjects without sacrificing image quality.

One of the defining characteristics of the VCC-WB4000 is its weather-resistant housing. Designed to withstand harsh outdoor conditions, this camera is sealed against dirt and moisture, making it suitable for various climates. Its durable construction not only enhances longevity but also reduces maintenance needs, ensuring consistent performance over time.

The Sanyo VCC-WB4000 also integrates advanced digital signal processing (DSP) technology, which optimizes image clarity and enhances features such as automatic gain control, backlight compensation, and noise reduction. This ensures clear images in both bright and low-light situations, providing reliable monitoring around the clock.

Another notable feature is its flexible installation options. The camera can be mounted on walls or ceilings with ease, and its compact design means it can fit into a variety of settings without drawing excessive attention.

Connectivity is also a strong point for the VCC-WB4000. It incorporates multiple output options, including analog video output, which simplifies integration with existing surveillance systems. This ensures that users can easily incorporate the camera into their security infrastructure without the need for extensive reconfiguration.

In conclusion, the Sanyo VCC-WB4000 is an excellent choice for those seeking a dependable outdoor surveillance solution. With its high-resolution imaging, robust weatherproof design, and advanced features, it stands as a testament to Sanyo’s commitment to providing effective security solutions. Whether for residential, commercial, or industrial applications, the VCC-WB4000 delivers the quality and reliability necessary to keep properties secure.