Sanyo VCC-WB4000 Playing Back Alarm Data in the Camera’s Internal Memory, Frame Rate

Page 46

L5AM2/US (VCC-WB4000) GB 2003, 6, 6

Playing Back Alarm Data

Alarm detection data (when an external sensor or motion detector have been set) and alarm image data is automatically recorded. Moreover, this data is also played back in the live image screen.

Playing Back Alarm Data in the Camera’s Internal Memory

1 Click the ALARM DATA indicator (while it is green or red).

The ALARM DATA LIST screen will be displayed, and an alarm image will be displayed as a still image in the PREVIEW screen.

2 Click the [PLAY] button.

The BUFFER DATA VIEW screen will be displayed (the PRE or POST indicator will illuminate) and playback of the alarm images will start. When playback is finished, the [POST] indicator will change to [END].

3 Click the [LIVE VIEW] menu select button.

The screen will return to the live image screen.

Descriptions of Alarm Operation Buttons

1 2 3 4

5 6 7

1[TOP] button

Playback returns to the beginning of the alarm data that is being played back and then waits in playback standby. You can then click the [PLAY] button to play back the data.

2[PLAY] button

Click this button during playback standby or when playback is paused to start playback.

3[STOP] button

If you click this button while playback is in progress, playback will stop.

4FRAME RATE

You can select the playback speed for alarm images using the drop-down list box. If you change the speed while alarm images are in the process of being played back, playback will start again at the selected speed from the beginning of the data.

Available settings: BASIC, MID, HIGH

Note: The actual playback speed will vary depending on the alarm data volume and the network status.

5[DOWNLOAD] button

Use this button to store alarm data on the computer.

6PRE/POST/END indicators

When alarm data is played back, this automatically appears as [PRE] (during pre-alarm image playback) or [POST] (during post-alarm image playback). When playback is finished, it changes to [END]. If there are no pre-alarm images, playback starts from the post-alarm images.

7[LIST] button

Click this button to switch to the ALARM DATA LIST screen.

English

– 45 –

Image 46
Contents VCC-WB4000 Network CameraContents For the customers in Canada Information to userPour la clientèle canadienne Precautions FeaturesAccessories Operating environmentName and Function of Each Part Monitor OUT connectorPower indicator Lens mount capName and Function of Each Part Remove the lens mount cap Attach the CS mount-type lens Attaching the LensFor C mount type Flange Back Adjustment Connections Basic ConnectionsConnecting to a LAN ConnectionsWired LAN Settings p Network Camera Wired LAN SettingsInstallation of Plug-in Software to the Computer p Computer Network SET Settings pTurn on the power for the computer Network Camera Wired LAN SettingsInstallation of Plug-in Software to the Computer Click the OK buttonUninstalling the plug-in software Click the Install buttonPlug-in software Cookie Settings Browser SettingsCamera uses cookies Example Subnet mask setting Type Wired LAN SettingsLanguage selection window Initial Camera Screen Image quality mode select buttonsAvailable settings Auto default setting FineAlarm indicator Wireless LAN buttonAlarm button Menu select buttonsRed indicator Lit orange alarm recording image playback is not possibleLit green alarm recording image playback is possible Grey indicatorSET button Resolution and Expansion settings default settings 640x480Selection screen example JImage display areaClick the Network menu select button Network SET SettingsSet the password Network SpeedWhen a password has been changed Changing a passwordMAC Address display Changing the Access Level ID2 or ID3 Turn the camera off and then back on againFor Operator access level Access Level SettingsFor User access level Timezone Clock SET SettingsDaylight Saving Mode Daylight SavingCamera Title Camera SettingsLive Image IrisCamera Settings Setting manual white balance ManualSetting the camera title DAY/NIGHT SettingsMode BurstSet Burst to OFF example Click the SET button Auto Mode SettingsColor Mode Settings Set Polarity to no exampleMode Settings Set AGC Gain to +12 dB example Click the SET buttonChange the DAY/NIGHT setting to Timer mode Color mode Timer modeChange the DAY/NIGHT setting to Color mode Connection example FigureAlarm Settings Click the Alarm menu select buttonAlarm Settings Alarm Buffering SET Setting Set Alarm Buffering to ON, and then click the Detail button External Alarm Sensor SettingAlarm Resolution Set Alarm REC USE to USE and then click the SET buttonMotion Detector SET Settings Set the sensor marksExternal Alarm Sensor and Motion Detector Settings Alarm Output for a Specified Period Motion Detector Level Sensitivity SettingRemote Alarm Operations Set Motion Detector Level to 2 exampleContinuous Alarm Output Set Buffering Area to PRE/POST 0/10 Pre-alarm/Post-alarm RecordingAlarm detected Set Buffering Area to PRE/POST 2/8Recording New Alarm Data Fixed Settings During Pre/Post-Alarm RecordingSaving to an Expansion Memory Card Alarm Data indicator green will illuminateInsert the expansion memory card Viewing Live Images Viewing the View Frame Screen Viewing Live ImagesClick the View Frame menu select button Descriptions of Alarm Operation Buttons Playing Back Alarm DataPlaying Back Alarm Data in the Camera’s Internal Memory Frame RateClick the Alarm Data indicator while it is red or green Playing Back Alarm DataPlaying Back Alarm Images Stored in a Computer Playing Back Expansion Memory Card ImagesEND ResolutionPrevious Alarm Data Deleting Saving Alarm Images onto a Computer as Still Images Saving Live Images and Alarm ImagesSaving Live Images onto a Computer When the File Download pop-up menu is displayed, click Save Saving Live Images and Alarm ImagesSaving All of a Single Alarm Event onto a Computer Click the Play button and then click the Download buttonWireless LAN device settings TCP/IP settings Wireless LAN SET SettingsCamera wired LAN settings TCP/IP settings Camera wireless LAN settings TCP/IP settingsWireless LAN SET Settings Camera Wireless LAN SettingsDescription of Wireless LAN SET Screen Encipherment SettingsConnecting the camera and installing the software PPP Dial-up SettingsPPP Connection to an Internet Service Provider Double-click the Camset icon on the desktopClick the Save Info File button PPP Dial-up SettingsClick the SET to Camera button Close the Camset windowAuthentication Dial to Provider SettingsProvider TEL. no Camera Computer Dial from PC SettingPPP Connection from a Computer Telephone lineMake the settings in the PPP setting screen Set the following itemsClick the RS-232C menu select button RS-232C Settings RS-232C SETLanguage Selection Click the Language button to change the languageFirmware Version Status CheckingClick the Status menu select button SUB-MICROCOMPUTER VersionGlossary of Terms Glossary of Terms Pre-alarm and post-alarm recording If the camera cannot be connected TroubleshootingIf you forget the IP Address Specifications Exclusions Printed on recycled paper 1AC6P1P2677 L5AM2/US 0603KP-CZ

VCC-WB4000 specifications

The Sanyo VCC-WB4000 is an advanced surveillance camera designed primarily for outdoor use, offering state-of-the-art features that cater to a variety of security needs. This robust model stands out for its high-resolution imaging capabilities combined with powerful technologies that ensure reliable performance in various lighting conditions.

At the heart of the VCC-WB4000 is its exceptional image sensor. The camera boasts a 1/3-inch CCD sensor, which delivers clear and detailed images with a resolution of up to 400 TV lines. This ensures that users can capture high-quality footage, even in challenging environments. Additionally, the camera’s 3x optical zoom lens allows for versatile viewing angles and the ability to focus on specific subjects without sacrificing image quality.

One of the defining characteristics of the VCC-WB4000 is its weather-resistant housing. Designed to withstand harsh outdoor conditions, this camera is sealed against dirt and moisture, making it suitable for various climates. Its durable construction not only enhances longevity but also reduces maintenance needs, ensuring consistent performance over time.

The Sanyo VCC-WB4000 also integrates advanced digital signal processing (DSP) technology, which optimizes image clarity and enhances features such as automatic gain control, backlight compensation, and noise reduction. This ensures clear images in both bright and low-light situations, providing reliable monitoring around the clock.

Another notable feature is its flexible installation options. The camera can be mounted on walls or ceilings with ease, and its compact design means it can fit into a variety of settings without drawing excessive attention.

Connectivity is also a strong point for the VCC-WB4000. It incorporates multiple output options, including analog video output, which simplifies integration with existing surveillance systems. This ensures that users can easily incorporate the camera into their security infrastructure without the need for extensive reconfiguration.

In conclusion, the Sanyo VCC-WB4000 is an excellent choice for those seeking a dependable outdoor surveillance solution. With its high-resolution imaging, robust weatherproof design, and advanced features, it stands as a testament to Sanyo’s commitment to providing effective security solutions. Whether for residential, commercial, or industrial applications, the VCC-WB4000 delivers the quality and reliability necessary to keep properties secure.