Sanyo VCC-WB4000 instruction manual Pre-alarm and post-alarm recording

Page 64

L5AM2/US (VCC-WB4000) GB 2003, 6, 6

Glossary of Terms

Pre-alarm and post-alarm recording

Pre-alarm and post-alarm recording involve recording data according to a selected ratio in the camera’s internal memory. The default ratio is pre-alarm = 0 / post-alarm = 10. When an alarm is detected in this condition, only post-alarm images are recorded in the camera’s internal memory.

Post-alarm recording is the recording of alarm data after an alarm has been detected by an external sensor or motion detector. When an alarm is detected, the alarm data is recorded into the internal memory according to the ratio selected. If the ratio is 0/10, all of the available memory space is devoted to post-alarm recording.

Pre-alarm recording sequentially records alarm images from immediately before the alarm was detected according to the ratio selected. When an alarm is detected, images from before the alarm that fall within the amount specified by the ratio selected are recorded in the pre-alarm area of the internal memory.

For example, if the alarm recording area of the internal memory is set to a ratio of 3/7, 30% of the available area is devoted to recording images from immediately before the alarm is detected. Actual alarm images are then recorded in the remaining 70%, and the pre-alarm and post-alarm recordings are treated as a single alarm event.

When alarm images are played back, the images can be viewed continuously starting from the first images recorded immediately before the alarm was detected. The alarm recording area ratio is an important point for consideration when making settings.

(Alarm input)

Post-alarm recording area (10)

(Internal memory: approx. 16 MB)

(Alarm input)

Pre-alarm recording area (3)

Post-alarm recording area (7)

(Internal memory: approx. 16 MB)

English

– 63 –

Image 64
Contents VCC-WB4000 Network CameraContents For the customers in Canada Information to userPour la clientèle canadienne Precautions FeaturesAccessories Operating environmentMonitor OUT connector Power indicatorName and Function of Each Part Lens mount capName and Function of Each Part Remove the lens mount cap Attach the CS mount-type lens Attaching the LensFor C mount type Flange Back Adjustment Connections Basic ConnectionsConnecting to a LAN ConnectionsNetwork Camera Wired LAN Settings Installation of Plug-in Software to the Computer pWired LAN Settings p Computer Network SET Settings pNetwork Camera Wired LAN Settings Installation of Plug-in Software to the ComputerTurn on the power for the computer Click the OK buttonUninstalling the plug-in software Click the Install buttonPlug-in software Cookie Settings Browser SettingsCamera uses cookies Example Subnet mask setting Type Wired LAN SettingsLanguage selection window Image quality mode select buttons Available settings Auto default settingInitial Camera Screen FineWireless LAN button Alarm buttonAlarm indicator Menu select buttonsLit orange alarm recording image playback is not possible Lit green alarm recording image playback is possibleRed indicator Grey indicatorResolution and Expansion settings default settings 640x480 Selection screen exampleSET button JImage display areaNetwork SET Settings Set the passwordClick the Network menu select button Network SpeedWhen a password has been changed Changing a passwordMAC Address display Changing the Access Level ID2 or ID3 Turn the camera off and then back on againFor Operator access level Access Level SettingsFor User access level Clock SET Settings Daylight Saving ModeTimezone Daylight SavingCamera Settings Live ImageCamera Title IrisCamera Settings Setting manual white balance ManualSetting the camera title DAY/NIGHT SettingsMode BurstAuto Mode Settings Color Mode SettingsSet Burst to OFF example Click the SET button Set Polarity to no exampleMode Settings Set AGC Gain to +12 dB example Click the SET buttonColor mode Timer mode Change the DAY/NIGHT setting to Color modeChange the DAY/NIGHT setting to Timer mode Connection example FigureAlarm Settings Click the Alarm menu select buttonAlarm Settings Alarm Buffering SET Setting External Alarm Sensor Setting Alarm ResolutionSet Alarm Buffering to ON, and then click the Detail button Set Alarm REC USE to USE and then click the SET buttonMotion Detector SET Settings Set the sensor marksExternal Alarm Sensor and Motion Detector Settings Motion Detector Level Sensitivity Setting Remote Alarm OperationsAlarm Output for a Specified Period Set Motion Detector Level to 2 exampleContinuous Alarm Output Pre-alarm/Post-alarm Recording Alarm detectedSet Buffering Area to PRE/POST 0/10 Set Buffering Area to PRE/POST 2/8Recording New Alarm Data Fixed Settings During Pre/Post-Alarm RecordingSaving to an Expansion Memory Card Alarm Data indicator green will illuminateInsert the expansion memory card Viewing Live Images Viewing the View Frame Screen Viewing Live ImagesClick the View Frame menu select button Playing Back Alarm Data Playing Back Alarm Data in the Camera’s Internal MemoryDescriptions of Alarm Operation Buttons Frame RatePlaying Back Alarm Data Playing Back Alarm Images Stored in a ComputerClick the Alarm Data indicator while it is red or green Playing Back Expansion Memory Card ImagesEND ResolutionPrevious Alarm Data Deleting Saving Alarm Images onto a Computer as Still Images Saving Live Images and Alarm ImagesSaving Live Images onto a Computer Saving Live Images and Alarm Images Saving All of a Single Alarm Event onto a ComputerWhen the File Download pop-up menu is displayed, click Save Click the Play button and then click the Download buttonWireless LAN SET Settings Camera wired LAN settings TCP/IP settingsWireless LAN device settings TCP/IP settings Camera wireless LAN settings TCP/IP settingsWireless LAN SET Settings Camera Wireless LAN SettingsDescription of Wireless LAN SET Screen Encipherment SettingsPPP Dial-up Settings PPP Connection to an Internet Service ProviderConnecting the camera and installing the software Double-click the Camset icon on the desktopPPP Dial-up Settings Click the SET to Camera buttonClick the Save Info File button Close the Camset windowAuthentication Dial to Provider SettingsProvider TEL. no Dial from PC Setting PPP Connection from a ComputerCamera Computer Telephone lineMake the settings in the PPP setting screen Set the following itemsRS-232C Settings RS-232C SET Language SelectionClick the RS-232C menu select button Click the Language button to change the languageStatus Checking Click the Status menu select buttonFirmware Version SUB-MICROCOMPUTER VersionGlossary of Terms Glossary of Terms Pre-alarm and post-alarm recording If the camera cannot be connected TroubleshootingIf you forget the IP Address Specifications Exclusions Printed on recycled paper 1AC6P1P2677 L5AM2/US 0603KP-CZ

VCC-WB4000 specifications

The Sanyo VCC-WB4000 is an advanced surveillance camera designed primarily for outdoor use, offering state-of-the-art features that cater to a variety of security needs. This robust model stands out for its high-resolution imaging capabilities combined with powerful technologies that ensure reliable performance in various lighting conditions.

At the heart of the VCC-WB4000 is its exceptional image sensor. The camera boasts a 1/3-inch CCD sensor, which delivers clear and detailed images with a resolution of up to 400 TV lines. This ensures that users can capture high-quality footage, even in challenging environments. Additionally, the camera’s 3x optical zoom lens allows for versatile viewing angles and the ability to focus on specific subjects without sacrificing image quality.

One of the defining characteristics of the VCC-WB4000 is its weather-resistant housing. Designed to withstand harsh outdoor conditions, this camera is sealed against dirt and moisture, making it suitable for various climates. Its durable construction not only enhances longevity but also reduces maintenance needs, ensuring consistent performance over time.

The Sanyo VCC-WB4000 also integrates advanced digital signal processing (DSP) technology, which optimizes image clarity and enhances features such as automatic gain control, backlight compensation, and noise reduction. This ensures clear images in both bright and low-light situations, providing reliable monitoring around the clock.

Another notable feature is its flexible installation options. The camera can be mounted on walls or ceilings with ease, and its compact design means it can fit into a variety of settings without drawing excessive attention.

Connectivity is also a strong point for the VCC-WB4000. It incorporates multiple output options, including analog video output, which simplifies integration with existing surveillance systems. This ensures that users can easily incorporate the camera into their security infrastructure without the need for extensive reconfiguration.

In conclusion, the Sanyo VCC-WB4000 is an excellent choice for those seeking a dependable outdoor surveillance solution. With its high-resolution imaging, robust weatherproof design, and advanced features, it stands as a testament to Sanyo’s commitment to providing effective security solutions. Whether for residential, commercial, or industrial applications, the VCC-WB4000 delivers the quality and reliability necessary to keep properties secure.