Hitachi CP-X2510N, CP-X3010N user manual Command control settings, TCP #9715 Command format

Page 13

Command Control via the Network (continued)

Command control settings

[TCP #23]

1. Command format

Same as RS-232C communication, refer to RS-232C Communicaton command format.

2. Response code / Error code ("h" shows hexadecimal)

Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added.

(1) ACK reply : 06h

Refer to RS-232C communication (&9).

(2)NAK reoly : 15h

Refer to RS-232C communication (&9).

(3)Error reply : 1Ch + 0000h

Refer to RS-232C communication (&9).

(4)Data reply : 1Dh + xxxxh

Refer to RS-232C communication (&9).

(5)Authentication error reply : 1Fh + 0400h

When authentication error occurred, the projector returns the error code.

[TCP #9715]

1. Command format

The commands some datum are added to the head and the end of the ones of TCP#9715 are used.

Header

Data length

RS-232C command

Check sum

Connection ID

 

 

 

 

 

0×02

0×0D

13 bytes

1 byte

1 byte

 

 

 

 

 

[Header]

02, Fixed

[Data Length]

RS-232C commands byte length (0×0D, Fixed)

[RS-232C commands]

Refer to RS-232C Communication command format (&9).

[Check Sum]

This is the value to make zero on the addition of the lower 8 bits from the header to the checksum.

[Connection ID]

Random value from 0 to 255 (This value is attached to the reply data).

NOTE • Operation cannot be guaranteed when the projector receives an undefined command or data.

Provide an interval of at least 40ms between the response code and any other code.

Commands are not accepted during warm-up.

13

Downloaded from www.Manualslib.com manuals search engine

Image 13
Contents CP-X2010N/CP-X2510N/CP-X3010N Example of computer signalInitial set signals Computer IN1, B Computer IN2, C Monitor OUT Connection to the portsVideo Audio IN1, J Audio IN2 USB To input component video signal to Computer in ports RS-232C Communication ConnectionProtocol Communicaion settingsResponse code / Error code h shows hexadecimal Command Control via the Network Port1 Port Communicaion PortTCP #9715 Command format Command control settingsAutomatic Connection Break AuthenticationNetwork Bridge Communication Communication settings On next RS-232C Communication / Network command tableDefault Be EF Custom C7 FF Be EF 7C FF 7C D1 Be EF Auto Adjust OFF Be EF Computer IN1 AB C3 Component Not all of the languages in the table are supported On next Original Be EF Active Iris is available only for CP-X2510N and CP-X3010N High Be EF Avmt PJLink commandInst ?