Hitachi CP-X3010N, CP-X2510N user manual Default Be EF Custom C7 FF

Page 18

RS-232C Communication / Network command table (continued)

Names 

Operation Type

Header

 

 

Command Data

CRC

Action

 

Type

Setting Code

GAMMA

Set

1 DEFAULT

BE EF

03

06

00

07

E9

01

00

A1 30

20

00

 

 

1 CUSTOM

BE EF

03

06

00

07

FD

01

00

A1 30

10

00

 

 

2 DEFAULT

BE EF

03

06

00

97

E8

01

00

A1 30

21

00

 

 

2 CUSTOM

BE EF

03

06

00

97

FC

01

00

A1 30

11

00

 

 

3 DEFAULT

BE EF

03

06

00

67

E8

01

00

A1 30

22

00

 

 

3 CUSTOM

BE EF

03

06

00

67

FC

01

00

A1 30

12

00

 

 

4 DEFAULT

BE EF

03

06

00

F7

E9

01

00

A1 30

23

00

 

 

4 CUSTOM

BE EF

03

06

00

F7

FD

01

00

A1 30

13

00

 

 

5 DEFAULT

BE EF

03

06

00

C7

EB

01

00

A1 30

24

00

 

 

5 CUSTOM

BE EF

03

06

00

C7 FF

01

00

A1 30

14

00

 

 

6 DEFAULT

BE EF

03

06

00

57

EA

01

00

A1 30

25

00

 

 

6 CUSTOM

BE EF

03

06

00

57

FE

01

00

A1 30

15

00

 

 

Get

BE EF

03

06

00

F4 F0

02

00

A1 30

00

00

User Gamma Pattern

Set

Off

BE EF

03

06

00

FB FA

01

00

80

30

00

00

 

 

9 steps gray scale

BE EF

03

06

00

6B

FB

01

00

80

30

01

00

 

 

15 steps gray scale

BE EF

03

06

00

9B

FB

01

00

80

30

02

00

 

 

Ramp

BE EF

03

06

00

0B FA

01

00

80

30

03

00

 

 

Get

BE EF

03

06

00

C8 FA

02

00

80

30

00

00

User Gamma Point 1

 

Get

BE EF

03

06

00

08

FE

02

00

90

30

00

00

 

 

Increment

BE EF

03

06

00

6E

FE

04

00

90

30

00

00

 

 

Decrement

BE EF

03

06

00

BF FF

05

00

90

30

00

00

User Gamma Point 1 Reset

 

Execute

BE EF

03

06

00

58

C2

06

00

50

70

00

00

User Gamma Point 2

 

Get

BE EF

03

06

00

F4

FF

02

00

91

30

00

00

 

 

Increment

BE EF

03

06

00

92

FF

04

00

91

30

00

00

 

 

Decrement

BE EF

03

06

00

43

FE

05

00

91

30

00

00

User Gamma Point 2 Reset

 

Execute

BE EF

03

06

00

A4

C3

06

00

51

70

00

00

User Gamma Point 3

 

Get

BE EF

03

06

00

B0 FF

02

00

92

30

00

00

 

 

Increment

BE EF

03

06

00

D6 FF

04

00

92

30

00

00

 

 

Decrement

BE EF

03

06

00

07

FE

05

00

92

30

00

00

User Gamma Point 3 Reset

 

Execute

BE EF

03

06

00

E0

C3

06

00

52

70

00

00

User Gamma Point 4

 

Get

BE EF

03

06

00

4C FE

02

00

93

30

00

00

 

 

Increment

BE EF

03

06

00

2A FE

04

00

93

30

00

00

 

 

Decrement

BE EF

03

06

00

FB FF

05

00

93

30

00

00

User Gamma Point 4 Reset

 

Execute

BE EF

03

06

00

1C C2

06

00

53

70

00

00

User Gamma Point 5

 

Get

BE EF

03

06

00

38

FF

02

00

94

30

00

00

 

 

Increment

BE EF

03

06

00

5E FF

04

00

94

30

00

00

 

 

Decrement

BE EF

03

06

00

8F

FE

05

00

94

30

00

00

User Gamma Point 5 Reset

 

Execute

BE EF

03

06

00

68

C3

06

00

54

70

00

00

User Gamma Point 6

 

Get

BE EF

03

06

00

C4 FE

02

00

95

30

00

00

 

 

Increment

BE EF

03

06

00

A2

FE

04

00

95

30

00

00

 

 

Decrement

BE EF

03

06

00

73

FF

05

00

95

30

00

00

User Gamma Point 6 Reset

 

Execute

BE EF

03

06

00

94

C2

06

00

55

70

00

00

User Gamma Point 7

 

Get

BE EF

03

06

00

80

FE

02

00

96

30

00

00

 

 

Increment

BE EF

03

06

00

E6

FE

04

00

96

30

00

00

 

 

Decrement

BE EF

03

06

00

37

FF

05

00

96

30

00

00

User Gamma Point 7 Reset

 

Execute

BE EF

03

06

00

D0 C2

06

00

56

70

00

00

(continued on next page)

18

Downloaded from www.Manualslib.com manuals search engine

Image 18
Contents Example of computer signal CP-X2010N/CP-X2510N/CP-X3010NInitial set signals Connection to the ports Computer IN1, B Computer IN2, C Monitor OUTVideo Audio IN1, J Audio IN2 USB To input component video signal to Computer in ports Connection RS-232C CommunicationCommunicaion settings ProtocolResponse code / Error code h shows hexadecimal Command Control via the Network Communicaion Port Port1 PortCommand control settings TCP #9715 Command formatAuthentication Automatic Connection BreakNetwork Bridge Communication Communication settings RS-232C Communication / Network command table On nextDefault Be EF Custom C7 FF Be EF 7C FF 7C D1 Be EF Auto Adjust OFF Be EF Computer IN1 AB C3 Component Not all of the languages in the table are supported On next Original Be EF Active Iris is available only for CP-X2510N and CP-X3010N High Be EF PJLink command AvmtInst ?
Related manuals
Manual 1 pages 10.35 Kb Manual 1 pages 27.63 Kb