Hitachi CP-X3010N, CP-X2510N user manual Response code / Error code h shows hexadecimal

Page 10

RS-232C Communication (continued)

3. Response code / Error code ("h" shows hexadecimal)

(1)ACK reply : 06h

When the projector receives the Set, Increment, Decrement or Execute command correctly, the projector changes the setting data for the specified item by [Type], and it returns the code.

(2)NAK reply : 15h

When the projector cannot understand the received command, the projector returns the error code.

In such a case, check the sending code and send the same command again.

(3)Error reply : 1Ch + 0000h

When the projector cannot execute the received command for any reasons, the projector returns the error code.

In such a case, check the sending code and the setting status of the projector.

(4)Data reply : 1Dh + xxxxh

When the projector receives the GET command correctly, the projector returns the responce code and 2 bytes of data.

NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect them correctly with suitable cables.

Operation cannot be guaranteed when the projector receives an undefined command or data.

Provide an interval of at least 40ms between the response code and any other code.

The projector outputs test data when the power supply is switched ON, and when the lamp is lit. Ignore this data.

Commands are not accepted during warm-up.

When the data length is greater than indicated by the data length code, the projector ignore the excess data code. Conversely when the data length is shorter than indicated by the data length code, the projector returns the error code to the computer.

10

Downloaded from www.Manualslib.com manuals search engine

Image 10
Contents Example of computer signal CP-X2010N/CP-X2510N/CP-X3010NInitial set signals Connection to the ports Computer IN1, B Computer IN2, C Monitor OUTVideo Audio IN1, J Audio IN2 USB To input component video signal to Computer in ports Connection RS-232C CommunicationCommunicaion settings ProtocolResponse code / Error code h shows hexadecimal Command Control via the Network Communicaion Port Port1 PortCommand control settings TCP #9715 Command formatAuthentication Automatic Connection BreakNetwork Bridge Communication Communication settings RS-232C Communication / Network command table On nextDefault Be EF Custom C7 FF Be EF 7C FF 7C D1 Be EF Auto Adjust OFF Be EF Computer IN1 AB C3 Component Not all of the languages in the table are supported On next Original Be EF Active Iris is available only for CP-X2510N and CP-X3010N High Be EF PJLink command AvmtInst ?