Hitachi CMP5000WXJ STANDBY/ON indicator, Panel sticking and after-image lag, Additional cautions

Page 37

Additional Information

Although this unit incorporates high precision technology in its design, please understand that there may be extremely slight pixel breakup, or light emission fault.

Note

In order to protect the panel and internal circuitry, this display is provided with a cooling fan designed to turn on/off and change speed automatically in accordance with ambient temperature conditions (the fan sound will change in accordance with its speed).

Additional cautions

If the power is automatically turned off during operation of this unit, the following reasons may be the cause.

1 Is the POWER MANAGEMENT or AUTO POWER OFF function set to ON? (page 20).

2Is ambient temperature too high?

3The internal temperature has risen abnormally due to blocked cooling vents, overheating of internal

electronic parts, or other factors.

4If the display is moved suddenly from a chilled location to a warm room, or if the room temperature rises suddenly, condensation may form on internal parts. To protect internal circuitry, the display is

provided with a condensation detector that automatically disables power in event of internal condensation; in this case, allow the unit to dry thoroughly before using.

If the power is automatically turned off for a reason other than the above reasons, there could be a malfunction. In this case, unplug the power cord from the power outlet and request repair from your nearest sales outlet.

The plasma display panel of this unit is very bright and viewing it a close distance will cause eye strain.

We recommend that you view the screen from a suitable distance (9.8 to 19.7 feet (3 to 6m)).

STANDBY/ON indicator

During operation of the Power Management function, the indicator will flash green at intervals of about 2 seconds (page 20). If the green light displays a flashing pattern other than the above, an error message is indicated. Consult any onscreen messages (page 27) and check ambient conditions (temperature, condensation, etc.) and respond accordingly (page 28-29).

If the problem persists, disconnect the power plug and consult your dealer or a service center.

When STANDBY/ON is pressed to set the unit to the standby mode, the indicator will flash red for several seconds (page 16). Other than this, if the power turns off by itself, or refuses to turn on, or if the red indicator conditions flashing, a malfunction may be indicated. Immediately disconnect the power plug and consult your dealer or a service center.

About the plasma panel’s protection function

The brightness of this display will deteriorate slightly when an image with little movement such as a photograph or computer image is continuously displayed. This is caused by the plasma panel’s protection function which detects images with slight movement and automatically adjusts brightness to protect the display, and is not a malfunction.

The screen-saver function begins operating when the display detects no or little screen movement for a period of about three minutes.

CAUTION

Panel sticking and after-image lag

Displaying the same images such as still images for a long time may cause after-image lagging.

This may occur in the following two cases.

1.After-image lagging due to remaining electrical load When image patterns with very high peak luminance are displayed for more than 1 minute, after-image lagging may occur due to the remaining electric load. The after-images remaining on the screen will disappear when moving images are displayed. The time for the after-images to disappear depends on the luminance of the still images and the time they had been displayed.

2.After-image (lag image) due to burning

Avoid displaying the same image on the Plasma Display continuously over a long period of time. If the same image is displayed continuously for several hours, or for shorter periods of time over several days, a permanent after-image may remain on the screen due to burning of the fluorescent materials. Such images may become less noticeable if

moving images are later displayed, but they will not disappear completely.

The power control function can be set to help prevent damage from screen burning (page 25).

Note

Special precautions must be employed when using the plasma display as a surveillance monitor or in other applications where a fixed image will be displayed for extended periods of time. Before using the monitor in such applications, consult your dealer for advice.

English

Additional Information

29

En

Image 37
Contents CMP5000WXU Manuel Utilisateur CMP5000WXJ English Safety Guidelines Safety GuidelinesSafety Guidelines III FCC Federal Communications Commission Statement Warning USER’S Manual ¶ Power-Saving Design ¶ Supports wide range of computer signal formats¶ Introduces newly developed 50 XGA Wide Plasma Panel ¶ High reliability for commercial applicationsContents Before Proceeding How to Use This ManualAbout operations in this manual Checking Supplied Accessories Main Unit Part Names and FunctionsMain unit Operation panel on the main unitInserting the batteries Remote control unit Remote Control UnitWhen handling the remote control unit Connection Panel Operating range of the remote control unitAudio Input Stereo mini jack ~ Speaker L terminalAudio Output Stereo mini jack Installation of the Unit Installation and ConnectionsWall-mount installation of the unit Rear view diagramInstallation and Connections When connecting to INPUT2Connection to INPUT1 and INPUT2 Connection to a personal computerWhen connecting to Output INPUT1 When connecting to INPUT1Connection of G on Sync analog RGB source Audio Connections Connecting the speakersConnection of composite Sync analog RGB Source Making connections to the audio inputs on this unitPower Cord Connection Organize cables together using the provided speed clamps How to Route CablesAndInstallation To attach the speed clamps to the main unitSetup after Connection Setting Up the SystemScreen Mode setup Setup of Clamp Position Clamp Position setupSetting Up the System Press 5/∞ to select Clamp Position Press SET to select LockedOperations Press STANDBY/ON to put this unit in the operation modeSelecting an Input Source Before you begin, make sure you havePress Volume on the remote control unit To adjust the volumePress Display on the remote control unit Press Muting on the remote control unitScreen Size Selection During personal computer signal inputChanging the screen size Press Screen Size to select the sizePartial Image Enlargement Press 5/∞ to select either the Power Automatic Power OFFManagement or Auto Power OFF mode When using InputAdjusting the Picture Quality Display Panel AdjustmentsTo reset Picture mode settings to the default Adjusting the Image Position and Clock Automatic Adjustment Press 2/3 to carry out the adjustment To reset Screen mode settings to the defaultScreen mode adjustment items Press 2/3 to select ScreenRewriting the Input Display Other OperationsOther Operations Press SET to select Input LabelPress SET to select Power Control Power Control FunctionPress 2/3 to select Option Press MenuOther Operations Press SET to select Input Audio Output Audio OUTPress 5/∞ to select Audio OUT Troubleshooting CleaningAbout the self diagnosis mode Additional InformationProblems commonly mistaken as breakdown General problemsPanel sticking and after-image lag STANDBY/ON indicatorAdditional cautions Accessories SpecificationsGeneral Input/outputSupplement PC signal compatibilty table INPUT1, INPUT2Information AdditionalPin No Input Output Supplement Explanation of Terms