Self Calibration (PA302W only)
Simply connect the external USB color sensor, and
Before proper self calibration can be performed, display should
NOTE:
Refer to the KEY MAP (Figure A) when changing settings during the calibration.
Calibration can be performed in either portrait or landscape orientation.
NOTE: You can start calibration without computer as following.
When there is “NO SIGNAL” menu, press “LEFT”, then “RIGHT” button and hold down simultaneously. All White Pattern Image will be displayed. After this,
English
USB color sensor
| USB icon ( ) | |
USB downstream | is on the | |
other side | ||
|
Figure S.1
KEY MAP
UP/DOWN: Changes from setting to setting
LEFT/RIGHT: Changes the setting selection (ie...SELF or COPY)
SELECT: Moves to the next step of calibration
EXIT: Moves back one step of calibration
Figure A
1.Select
2.Unplug the USB equipment from the side (or bottom when Portrait orientation) USB downstream port and press “SELECT”.
3.
4.The calibration menu will open and the sensor will begin to initialize.
Figure S.2
5. Use “LEFT” or “RIGHT” to select SELF in the MODE selection. Press “UP” or “DOWN” to move to the next selection.