Installing the System

 

Connecting the Hospitality Adjuncts

51

 

 

INTUITY Lodging Call Accounting-to-PMS Link

This connection is used to transmit the call accounting information from the MAP to the PMS. This call detail information has been reformatted from its format on the switch for use by the PMS.

NOTE:

This link between the co-resident INTUITY Lodging Call Accounting package and the PMS is required to transmit call detail records between the call accounting system and the PMS. This link is separate and distinct from the INTUITY Lodging-to-PMS link described on page 30.

Parts List

One Multi-Port Serial card on the MAP (comcode 407009406; J1P260AA1, List 12)

For this connection, use the second port on the card. This port is not marked on the card, but is administered in software as port TTYsab.

One D6AP modular cord (comcode 102937604)

One Equinox P/N:210068 DTE 10/10 adapter (DB25 DTE, comcode 406983155); see “Appendix B — Connector Pinouts”

Gender changers, as needed.

Distance Limits

The distance limit from the MAP to the PMS is 50 feet (15.2 meters).