GuestWorks and DEFINITY ECS Release 9 | Issue 1 |
Technician Handbook for Hospitality Installations | November 2000 |
Translations and Testing |
|
Miscellaneous Translations | 128 |
|
|
The following screen shows how you would then administer station hunting from secondary extension 7887 to secondary extension 7897.
change station 7887 |
|
| Page | 1 of 3 | |
|
| STATION |
|
|
|
Extension: | 7887 | Lock Messages? | n |
| BCC: 0 |
Type: | CallrID | Security Code: |
|
| TN: 1 |
Port: | 01A0201 | Coverage Path 1: | 1 |
| COR: 1 |
Name: |
| Coverage Path 2: |
|
| COS: 1 |
|
|
| 7897 | Tests? y |
STATION OPTIONS |
|
|
Loss Group: 1 | Message Waiting Indicator: led | |
Off Premise Station? n | Message Lamp Ext: | 7887 |
| Display Caller ID: | y |
| Caller ID Message Waiting Indication? | n |
You would repeat this administration for each telephone in the hunting group.
Administering Station Hunt Before Coverage
Use the change
change | Page | 1 of 2 |
SYSTEM PARAMETERS - CALL COVERAGE/CALL FORWARDING |
|
CALL COVERAGE/FORWARDING PARAMETERS
Local Cvg Subsequent Redirection/CFWD No Ans Interval (rings): 2
Coverage - Caller Response Interval (seconds): 4
Threshold For Blocking
COVERAGE
Keep Held SBA At Coverage Point? y
External Cvg Treatment For G3 Transferred Calls to G2 Supporting AUDIX? n
Immediate Redirection on Receipt of PROGRESS Inband Information? n
Maintain SBA At Principal? y
Station Hunt Before Coverage? y
FORWARDING
Call Forward Override? n
Coverage after Forwarding? y