GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Installing the System

 

Connecting the Hospitality Adjuncts

37

 

 

Test Procedure

Using the RS232 Mini-Tester (see the Note on page 5), check the status of the link where the Equinox adapter connects to the M25A cable as shown in Figure 12. The leads marked with an asterisk are controlled by the switch, and the INTUITY Lodging Call Accounting system controls the other leads. Translations for this begin on page 205.

!CAUTION:

After using a mini-tester to check data leads, you MUST remove the mini-tester from the connection. DO NOT leave the mini-tester in-line during actual operation.

With the mini-tester connected to only the M25A cable, the mini-tester should show the following:

TD dark

red RD*

RTS dark

green CTS*

DSR* green

dark DTR

CD* green

With the mini-tester connected to only the Equinox adapter, the mini-tester should show the following:

TD red

dark RD*

RTS dark

dark CTS*

DSR* dark

green DTR

CD* red

Page 53
Image 53
Avaya 555-231-743 manual Test Procedure