GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Installing the System

 

Connecting the Hospitality Adjuncts

35

 

 

Co-Resident INTUITY Lodging Call Accounting

Link Using the DCE Port

This connection is used to transfer Call Detail Recording (CDR) information to the co-resident INTUITY Lodging Call Accounting software (Homisco). This connection is valid for a csi or si system.

Parts List

The DCE port on the switch (this port is found on the Processor Interface Cable of a csi system labeled as J2)

One M25A RS232 cable (or equivalent straight-through cable) (comcode 105193668)

One Equinox P/N:210068 DTE 10/10 adapter (DB25 DTE, comcode 406983155); see “Appendix B — Connector Pinouts”

One D6AP modular cord (comcode 102937604)

One Multi-Port Serial card on the MAP (comcode 407009406; J1P260AA1, List 12).

For this connection, use the first port on the card. This port is not marked on the card, but is administered in software as port TTYsaa.

Distance Limits

The distance limit from the switch to the MAP is 50 feet (15.2 meters). If the distance from the switch and the MAP is more than 50 feet (15.2 meters), or if the switch is an r system, see “Switch-to-Call Accounting Link using DCP Data Modules” on page 46.