Translations and Testing
124Miscellaneous Translations
Administering Analog Caller ID (Switch)
The TN2793B and TN793B analog line circuit packs can be administered to
deliver Incoming Calling Line Identification (ICLID) data to stand-alone an alog
Caller ID display units or analog telephones with built-in Caller ID displa y units.
For this feature to work, the serving central office (CO) must support delivery of
Caller ID information over the trunks that are serving the switch. To administer this
feature, do the following:
Administer the Caller ID system options.
Administer stations with Caller ID options.
Administering Caller ID
Use the change system-parameters features command to select the Caller ID
protocol that matches the protocol used by the Caller ID units or telephones, a nd
to enable display of Caller ID information for room-to-room calls. Thes e options
are set on a system-wide basis. Administer the following options:
Protocol for Caller ID Analog Terminals — The available
protocols include:
Bellcore (default) — US protocol (Bellcore transmission protocol
with 212 modem protocol)
V23-Bell — Bahrain protocol (Bellcore transmission protocol with
V.23 modem protocol).
Display Calling Number for Room to Room Caller ID Calls
— Enter y to display both name and number, or n to display name only.
The information displayed on the telephone may be a secur ity issue for the
customer.
change system-parameters features Page 1 of 10
FEATURE-RELATED SYSTEM PARAMETERS
Self Station Display Enabled? y
Trunk-to-Trunk Transfer: none
Automatic Callback - No Answer Timeout Interval (rings): 3
Call Park Timeout Interval (minutes): 10
Off-Premises Tone Detect Timeout Interval (seconds): 20
AAR/ARS Dial Tone Required? y
Music/Tone on Hold: music Port: 01B1101
Music (or Silence) on Transferred Trunk Calls? no
DID/Tie/ISDN Intercept Treatment: attd
Messaging Service Adjunct (MSA) Connected? n
Internal Automatic Answer for Attendant Extended Calls? n
Automatic Circuit Assurance (ACA) Enabled? y
ACA Referral Calls: local
ACA Referral Destination: attd
ACA Short Holding Time Originating Extension: 3070
ACA Long Holding Time Originating Extension: 3070
Abbreviated Dial Programming by Assigned Lists? n
Auto Abbreviated/Delayed Transition Interval (rings): 2
Protocol for Caller ID Analog Terminals: Bellcore
Display Calling Number for Room to Room Caller ID Calls? n