GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Installing the System

 

Connecting the Hospitality Adjuncts

77

 

 

INADS Alarm Origination Download

You can have the Comsphere 3820 or the RMB automatically configured by doing an alarm origination download. To start this download, do the following:

1.Use the Customer/Services Administration > Alarm Management command to display the following screen:

+-----------------------------------------------

 

+

+

Alarm Management

 

+

+-----------------------------------------------

 

+

Product ID

 

2200000000

 

 

Alarm Destination

18005353573

 

 

Alarm Origination

ACTIVE

 

 

Alarm Level

 

MAJOR

 

 

Alarm Suppression

INACTIVE

 

 

Clear Alarm Notification

ACTIVE

+-----------------------------------------------

 

+

2.Enter the information as shown in the screen, using your actual Product ID and Alarm Destination phone number (the INADS number).

3. Once the options are correct, press F3 to save the options. Press Enter to continue.

4.Press F8 to select the Chg Keys function.

5.Press F1 to select the Test Alrm function.

6.Select the Execute Alarm Origination Test menu item.

7.Press y to start the test. The alarm origination download takes 2 to 5 minutes to complete.

8.After the download is complete, select the Review Latest Test Results menu item. The result message should say Alarm origination test successful.

For more details on this procedure, see the appropriate MAP installation document.