The options for the 7400A used for printers are given in Table 6. These options must match the printer communication parameters, which are usually 9600 bps, 8 data bits, 1 stop bit, and no parity.

The data module interface board must be positioned at the DCE location, and the interface option must be set for Answer-Only mode.

Table 6. 7400A Options for Printers

Set Interface

Set Values

 

 

Option

Answer-only mode

 

 

 

 

Set Option Displays

Set Values

 

 

* Set 300 speed

OFF

 

 

* Set 1200 speed

OFF

 

 

* Set 2400 speed

OFF

 

 

* Set 4800 speed

OFF

 

 

* Set 9600 speed

ON

 

 

* Set 19200 speed

OFF

 

 

Set Answer

AUTO

 

 

Set Break DISC

LONG

 

 

Set CI Lead

OFF

 

 

Set CH Lead

OFF

 

 

Set CTS Lead

NORMAL

 

 

Set DCD Lead

NORMAL

 

 

Set DSR Lead

NORMAL

 

 

Set DTR Detect

50

 

 

Set DTR Lead

FOLLOW

 

 

Set LL Lead

OFF

 

 

Set Remote Loop

GRANT

 

 

Set RI Lead

ON

 

 

Set RL Lead

OFF

 

 

Set SIGLS DISC

ON

 

 

Set TM Lead

OFF

 

 

* Match the speed based on the printer settings.