GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743 Issue 1
November 2000
Translations and Testing
181Switch-to-INTUITY Translations
Mode Code Integration
The Mode Code Integration link requires administration on both the switch and the
INTUITY. Any switch types can use Mode Code Integration, but TCP/IP or X.25
are the recommended methods for messaging links.
Mode Code Integration Link (Switch)
Translating the Mode Code Integration link involves the following:
Enabling the Mode Code feature
Verifying that the default mode codes are accurate.
Mode Code Integration on the switch is described in the

DEFINITY ECS

Administrator’s Guide.

Use the display system-parameters features command, Page 5, to verify that
there is a y in the Mode Code Interface field.
change system-parameters features Page 5 of 10
FEATURE-RELATED SYSTEM PARAMETERS
Public Network Trunks on Conference Call: 5 Auto Start? n
Conference Parties with Public Network Trunks: 6 Auto Hold? n
Conference Parties without Public Network Trunks: 6 Attendant Tone? y
Night Service Disconnect Timer (seconds): 180 Bridging Tone? n
Short Interdigit Timer (seconds): 3 Conference Tone? n
Unanswered DID Call Timer (seconds): Intrusion Tone? n
Line Intercept Tone Timer (seconds): 30 Special Dial Tone? n
Long Hold Recall Timer (seconds): 0 Mode Code Interface? y
Reset Shift Timer (seconds): 0
Station Call Transfer Recall Timer (seconds): 0
DID Busy Treatment: tone
Allow AAR/ARS Access from DID/DIOD? n
Allow ANI Restriction on AAR/ARS? n Transfer Upon Hang-Up? n
Abort Conference Upon Hang-Up? n Abort Transfer? n
7405ND Numeric Terminal Display? n 7434ND? n
DISTINCTIVE AUDIBLE ALERTING
Internal: 1 External: 2 Priority: 3
Attendant Originated Calls: external